-
161
-
162
Do Clopidogrel Nonresponders Have an Increased Risk of Adverse Events during Supra-Aortal Angioplasty and Stenting?
Published 2012-01-01“…The aim of the present study was to correlate new periprocedural diffusion-weighted imaging (DWI) lesions during stenting of supra-aortal arteries with the level of platelet inhibition using point-of-care analysis. …”
Get full text
Article -
163
-
164
Modelling chemistry and biology after implantation of a drug-eluting stent. Part Ⅰ: Drug transport
Published 2017-03-01Subjects: “…drug-eluting stents…”
Get full text
Article -
165
Recovery process of patients with iliac vein compression syndrome after stenting: a grounded theory study
Published 2025-01-01Subjects: Get full text
Article -
166
Intraoperative dynamics of interleukin-6 levels during planned coronary stenting with different approaches to analgesic sedation
Published 2020-10-01Subjects: Get full text
Article -
167
Follow-up computed tomography can prevent stent migration after endoscopic ultrasound-guided hepaticogastrostomy
Published 2025-01-01“…As treatment, we performed endoscopic ultrasound-guided hepaticogastrostomy and placed a self-expanding metal stent. Computed tomography was performed immediately after the procedure to ensure proper stent placement. …”
Get full text
Article -
168
Comparison of biodegradable and durable polymer drug-eluting stents in acute coronary syndrome: a meta-analysis
Published 2022-06-01“…Objective To compare the safety and effectiveness between biodegradable polymer drug-eluting stents (BP-DES) and durable polymer drug-eluting stents (DP-DES) in patients with acute coronary syndrome (ACS).Design Meta-analysis of randomised controlled trials (RCTs).Primary and secondary outcome measures Major adverse cardiovascular events (MACEs) were considered the primary endpoint. …”
Get full text
Article -
169
Stent Thrombosis Patients with Hyporesponsiveness to Clopidogrel, Prasugrel, and Ticagrelor: A Case Series Using Short Thromboelastography
Published 2016-01-01“…Patients after percutaneous coronary intervention (PCI) with stent implantation and functional hyporesponsiveness to P2Y12 inhibitors are at higher risk of ischaemic events, particularly stent thrombosis (ST). …”
Get full text
Article -
170
A Complication of an Endoscopic Pigtail Stent Migration into the Cavity during Deployment as a Treatment for Gastric Leak
Published 2019-01-01“…Complications to this approach include bleeding, ulceration at the tip of the double-pigtail stent, and uncommon migration. Here, we report our experience with drain displacement into the cavity while deployment in a patient who experienced gastric leakage after undergoing sleeve gastrectomy.…”
Get full text
Article -
171
Simultaneous Multi-Vessel Very Late Stent Thrombosis in Acute ST-Segment Elevation Myocardial Infarction
Published 2021-01-01“…Simultaneous multi-vessel very later stent thrombosis (VLST) is a very rare complication of percutaneous coronary intervention (PCI). …”
Get full text
Article -
172
Modern options of endoscopic retrograde stenting of bile ducts in treatment of obstructive jaundice at malignant pancreatobiliary tumors
Published 2014-11-01Subjects: Get full text
Article -
173
Predictors of Stent Restenosis in Han and Uygur Patients with Coronary Heart Disease after PCI in the Xinjiang Region
Published 2022-01-01“…Background. Stent restenosis after PCI seriously affects the efficacy and prognosis; therefore, the study of ISR risk factors has become an urgent topic to be solved. …”
Get full text
Article -
174
Stent Selection for Endoscopic Ultrasound-Guided Drainage of Pancreatic Fluid Collections: A Multicenter Study in China
Published 2014-01-01“…Clinical success for single-stent drainage was 93.9% (46/49) versus 97.4% (37/38) for multiple-stent drainage (P=0.799). …”
Get full text
Article -
175
Colonic Stents for Colorectal Cancer Are Seldom Used and Mainly for Palliation of Obstruction: A Population-Based Study
Published 2016-01-01“…Self-expandable stents for obstructing colorectal cancer (CRC) offer an alternative to operative management. …”
Get full text
Article -
176
Satisfactory Evaluation of Call Service Using AI After Ureteral Stent Insertion: Randomized Controlled Trial
Published 2025-01-01“… BackgroundUreteral stents, such as double-J stents, have become indispensable in urologic procedures but are associated with complications like hematuria and pain. …”
Get full text
Article -
177
Three-Dimensional Dual-Energy Computed Tomography for Enhancing Stone/Stent Contrasting and Stone Visualization in Urolithiasis
Published 2013-01-01“…Regardless of the stone type, ureteral stents are often placed to prevent or treat obstruction. …”
Get full text
Article -
178
Modelling the Effect of SPION Size in a Stent Assisted Magnetic Drug Targeting System with Interparticle Interactions
Published 2015-01-01“…Here, we develop a mathematical model for studying the interactions between the MDCPs enriched with three different diameters of SPIONs (6.6, 11.6, and 17.8 nm) in the MDT system with an implanted magnetizable stent using different magnetic field strengths and blood velocities. …”
Get full text
Article -
179
Successful Stent Graft Insertion for Endovascular Aneurysm Repair and Closure of Patent Ductus Arteriosus in an Adult Patient
Published 2015-01-01“…We present the case of a 72-year-old female patient who underwent successful stent graft insertions for PDA with TAA.…”
Get full text
Article -
180
Spontaneous-Idiopathic Left Anterior Descending Artery Dissection: Is Watchful Waiting Better Than Immediate Stenting?
Published 2013-01-01“…Due to patient’s stable clinical and hemodynamic parameters, we used a cautious approach based on watchful waiting and medical therapy, postponing stenting in order to achieve a partial vessel reopening with a more comfortable access to PCI.…”
Get full text
Article