Showing 1 - 20 results of 60 for search '"matrix effects"', query time: 0.07s Refine Results
  1. 1
  2. 2
  3. 3
  4. 4

    Application of Liquid Chromatography-Tandem Mass Spectrometry for the Detection of Paralytic Shellfish Poison in Bivalve Shellfish and Its Influencing Factors by DENG Yuxiang, WU Haiyan, XU Xizhen, ZHAO Huihui, TAN Zhijun, ZHENG Guanchao

    Published 2025-01-01
    “…The major factors affecting matrix effects includes endogenous interferences such as phospholipids and proteins and exogenous interferences such as organic substances and polymer residues in the detection methods. …”
    Get full text
    Article
  5. 5

    Simultaneous Determination of 13 Constituents of Radix Polygoni Multiflori in Rat Plasma and Its Application in a Pharmacokinetic Study by Wenhao Cheng, Yinghui Li, Wei Yang, Siyang Wu, Mengmeng Wei, Yang Gao, Chen Kang, Shuofeng Zhang, Yingfei Li

    Published 2020-01-01
    “…The method was fully validated in terms of selectivity, linearity, accuracy, precision, recovery, matrix effects, and stability. The lower limit of quantitation of the analytes was 0.1–1 ng/mL. …”
    Get full text
    Article
  6. 6

    ANALYSIS OF TRACE ELEMENT CONCENTRATIONS IN ARTICHOKES AT DALAT USING TOTAL REFLECTION X-RAY FLUORESCENCE by Nguyễn Thị Minh Sang, Phạm Thị Ngọc Hà, Nguyễn Thị Nguyệt Hà, Nguyễn An Sơn

    Published 2020-09-01
    “…The main benefits of TXRF include simplicity, rapid measurement, simultaneous determination of the concentrations of many elements, small sample size, and no matrix effects. This study aimed to determine the concentrations of inorganic elements in locally grown artichokes. …”
    Get full text
    Article
  7. 7

    Determination of Tropifexor in Beagle Dog Plasma by UPLC-MS/MS and Its Application in Pharmacokinetics by Yan-Ding Su, Xin-Yi Wei, Xiao-Hang Su, Ghulam Woshur, Xiao-Nan Geng, Xiang-Jun Qiu

    Published 2022-01-01
    “…The recoveries of the analytes were >88.13% and were free of significant matrix effects. The stability met the requirements for the quantification of plasma samples under various conditions. …”
    Get full text
    Article
  8. 8

    Direct Determination of Flavanone Isomers in Citrus Juice by Paper Spray Tandem Mass Spectrometry by Lucia Bartella, Fabio Mazzotti, Ilaria Santoro, Ines Rosita Talarico, Leonardo Di Donna

    Published 2024-12-01
    “…The method demonstrated excellent analytical performance, with high accuracy, selectivity, and reproducibility. The impact of matrix effects was mitigated through the construction of ratio calibration curves, ensuring reliable quantification in complex matrices. …”
    Get full text
    Article
  9. 9

    Simultaneous Determination of Five Components of Chaihu-Shugan-San in Beagle Plasma by HPLC-MS/MS and Its Application to a Pharmacokinetic Study after a Single Dose of Chaihu-Shuga... by Yong-liang Zhu, Hui-jun Wang, Hao Xue, Yi Zhang, Qian-shi Cheng, Ling-yun Chen, Xiang-jun Qiu

    Published 2020-01-01
    “…The recovery rate (n = 6) of the five analytes was between 85.42% and 90.85%, and the matrix effects (n = 6) were between 94.52% and 103.91%. …”
    Get full text
    Article
  10. 10

    4-Thiobenzoic acid-functionalized nanocomposite probes for surface-enhanced raman spectroscopy-based detection of CA19-9 in colorectal adenocarcinoma by Yinan Hu, Tao Liu, Bo Guo, Miao Ni, Yanrong Li

    Published 2025-04-01
    “…Recovery studies in spiked serum samples yielded results ranging from 94.5 % to 105.2 %, indicating minimal matrix effects. Clinical validation using 70 serum samples (50 colorectal adenocarcinoma patients, 20 healthy volunteers) showed strong agreement with a commercial ELISA kit (Pearson's r = 0.987, p < 0.0001). …”
    Get full text
    Article
  11. 11

    Carboxylated Multiwalled Carbon Nanotubes as Dispersive Solid-Phase Extraction Sorbent to Determine Eighteen Polychlorinated Biphenyls in Vegetable Samples by Gas Chromatography-Ma... by Tengfei Liu, Daifeng Yang, Jian Mao, Xueming Zhang, Minghui Dong

    Published 2019-01-01
    “…Parameters affecting both the extraction yields and cleanup efficiency, including the type and volume of extraction solvent, extraction time, type and volume of cleanup sorbent, and cleanup time, were optimized. Matrix effects were evaluated, and matrix-matched calibration was recommended. …”
    Get full text
    Article
  12. 12

    Simultaneous determination of 15 pesticide residues in Chinese cabbage and cucumber by liquid chromatography-tandem mass spectrometry utilizing online turbulent flow chromatography by Sufang Fan, Junmei Ma, Meirong Cao, Juan Wang, Leilei Zhang, Yan Zhang, Qiang Li, Jia Chen

    Published 2021-01-01
    “…Recoveries of pesticide residues were in range of 75.3%–103.7%. Matrix effects for 15 pesticides were in range of 5.6%–106.6%. …”
    Get full text
    Article
  13. 13

    Pharmacokinetics and Bioavailability Study of Tubeimoside I in ICR Mice by UPLC-MS/MS by Lianguo Chen, Qinghua Weng, Feifei Li, Jinlai Liu, Xueliang Zhang, Yunfang Zhou

    Published 2018-01-01
    “…The average recovery was >66.9%, and the matrix effects were from 104.8% to 111.0%. In this assay, a fast, highly sensitive, and reproducible quantitative method was developed and validated in mouse blood for the first time. …”
    Get full text
    Article
  14. 14

    Pharmacokinetic Analysis of Diosgenin in Rat Plasma by a UPLC-MS/MS Approach by Pei Liu, Lin Xu, Jing-han Guo, Jin-hua Chang, Xi-gang Liu, He-fei Xue, Ru-xing Wang, Zhong-si Li, Guang-xin Miao, Cui-zhe Liu, Jian-yu Zhou

    Published 2022-01-01
    “…The recoveries of diosgenin and tanshinone IIA were 85.81–100.27% and 98.29%, respectively, with negligible matrix effects. Diosgenin and IS were stable under multiple storage conditions. …”
    Get full text
    Article
  15. 15

    Green analysis of illicit drugs on banknote dust by Teresa Cecchi, Arianna Giuliani, Carlo Catini

    Published 2025-03-01
    “…A UHPLCHRMS system with ethanol as the organic modifier was used to develop and optimize the chromatographic method; a stable isotope labelled internal standard for each analyte was used to compensate matrix effects and possible losses. The Levene test, Mandel's test, and Shapiro-Wilk's test were used to obtain the best calibration model. …”
    Get full text
    Article
  16. 16

    Optimization of the Extraction Protocol for Pacific Ciguatoxins from Marine Products Prior to Analysis Using the Neuroblastoma Cell-Based Assay by Thomas Yon, Philippe Cruchet, Jérôme Viallon, J. Sam Murray, Emillie Passfield, Mireille Chinain, Hélène Taiana Darius, Mélanie Roué

    Published 2025-01-01
    “…In addition, a reduction in adverse matrix effects in the CBA-N2a analyses was demonstrated with naturally contaminated specimens, increasing the sensitivity of the method, which now meets the very low guidance level recommended by international agencies. …”
    Get full text
    Article
  17. 17

    Simultaneous Determination of Multiple Acid-Suppressing Drugs by UPLC-MS/MS Method and Application for Pharmacokinetics Study by Li X, Liu S, Yu M, Xi W, Wu X, Liu D, Liu A, Wang H

    Published 2025-02-01
    “…Extraction recoveries were consistent, ranging from 88.1% to 96.7%, with no significant matrix effects observed. The stability of the six analytes under diverse storage and processing conditions was also confirmed, with both precision and accuracy falling within the acceptable range of 15%. …”
    Get full text
    Article
  18. 18
  19. 19

    Effect of Pretreatment on Detection of 37 Pesticide Residues in Chrysanthemum indicum by Xiao-Ying Lu, Yan-Qin Ouyang, Wei-Ya Zeng, Cui-Qing Lin, Lu-Hua Xiao, Gui-Hua Luo, Ruo-Ting Zhan, Ping Yan

    Published 2021-01-01
    “…The influence of QuEChERS extraction and matrix solid-phase dispersion (MSPD) on the recovery and matrix effect (ME) was compared. extraction and matrix solid-phase dispersion (MSPD) on the recovery and matrix effect (ME) was compared to decrease the ME. …”
    Get full text
    Article
  20. 20

    Economic Spectrofluorometric Bioanalysis of Empagliflozin in Rats’ Plasma by Bassam Ayoub, Noha El Zahar, Haidy Michel, Mariam Tadros

    Published 2021-01-01
    “…The method was validated with satisfactory results for linearity (500–5000 ng/mL), trueness, precision, the matrix effect, and extraction recovery. The matrix effect ranged between 15.63% and 23.10% for LQC and HQC samples, respectively. …”
    Get full text
    Article