Showing 1,621 - 1,640 results of 5,787 for search '"magnet"', query time: 0.06s Refine Results
  1. 1621
  2. 1622

    Mixed Convective-Radiative Dissipative Magnetized Micropolar Nanofluid Flow over a Stretching Surface in Porous Media with Double Stratification and Chemical Reaction Effects: ADM-Padé Computation by P. K. Pattnaik, M. M. Bhatti, S. R. Mishra, Munawwar Ali Abbas, O. Anwar Bég

    Published 2022-01-01
    “…The present study deals with the electrically conducting micropolar nanofluid flow from a vertical stretching surface adjacent to a porous medium under a transverse magnetic field. Eringen’s micropolar model is deployed for non-Newtonian characteristics and the Buongiorno nanofluid model employed for nanoscale effects (thermophoresis and Brownian motion). …”
    Get full text
    Article
  3. 1623
  4. 1624
  5. 1625
  6. 1626
  7. 1627
  8. 1628
  9. 1629
  10. 1630

    Investigation of a Spin-0 Massive Charged Particle Subject to a Homogeneous Magnetic Field with Potentials in a Topologically Trivial Flat Class of Gödel-Type Space-Time by Faizuddin Ahmed

    Published 2020-01-01
    “…In this paper, we investigate the relativistic quantum dynamics of spin-0 massive charged particle subject to a homogeneous magnetic field in the Gödel-type space-time with potentials. …”
    Get full text
    Article
  11. 1631

    Magnetic resonance angiography in diagnostic long-term follow-up of primary patency of the MOTIV drug-eluting bioresorbable vascular scaffold in the region below the knee: 5 years of experience. by Christian Nasel, Mario Kirschner, Karoline Rizzi, Nicola Schweinhammer, Ewald Moser

    Published 2025-01-01
    “…In the BTK-region metallic drug-eluting stents (mDES) yielded best results concerning primary patency (PP), but also annihilate signal in magnetic resonance angiography (MR-A). A recently introduced non-metallic drug eluting bioresorbable Tyrocore® vascular scaffold (deBVS), that offers an option for re-treatment of lesions due to its full degradation within 3-4 years after placement, was investigated with respect to its compatibility with MR-A to unimpededly depict previously treated target lesions.…”
    Get full text
    Article
  12. 1632

    Nanoscale Pore Structure Characterization and Permeability of Mudrocks and Fine-Grained Sandstones in Coal Reservoirs by Scanning Electron Microscopy, Mercury Intrusion Porosimetry, and Low-Field Nuclear Magnetic Resonance by Na Zhang, Fangfang Zhao, Pingye Guo, Jiabin Li, Weili Gong, Zhibiao Guo, Xiaoming Sun

    Published 2018-01-01
    “…Meanwhile, pore types, pore morphologies, and pore size distributions (PSD) were determined by focused ion beam scanning electron microscopy (FIB-SEM), mercury intrusion porosimetry (MIP), and low-field nuclear magnetic resonance (NMR). FIB-SEM image analyses showed that the mineral matrix pores including interparticle (interP) and intraparticle (intraP) pores with varied morphologies are the dominant pore types of the investigated rock samples while very few organic matter (OM) pores were observed. …”
    Get full text
    Article
  13. 1633
  14. 1634
  15. 1635
  16. 1636
  17. 1637

    Analytical Analysis of Effects of Buoyancy, Internal Heat Generation, Magnetic Field, and Thermal Radiation on a Boundary Layer over a Vertical Plate with a Convective Surface Boundary Condition by Solomon Bati Kejela, Mitiku Daba Firdi

    Published 2020-01-01
    “…In this paper, the effects of magnetic field, thermal radiation, buoyancy force, and internal heat generation on the laminar boundary layer flow about a vertical plate in the presence of a convective surface boundary condition have been investigated. …”
    Get full text
    Article
  18. 1638

    Inhibition of Viability, Proliferation, Cytokines Secretion, Surface Antigen Expression, and Adipogenic and Osteogenic Differentiation of Adipose-Derived Stem Cells by Seven-Day Exposure to 0.5 T Static Magnetic Fields by Jian Wang, Bo Xiang, Jixian Deng, Darren H. Freed, Rakesh C. Arora, Ganghong Tian

    Published 2016-01-01
    “…After seven-day exposure to 0.5-Tesla Static Magnetic Field (SMF), Adipose-derived Stem Cells (ASCs) and those labeled by superparamagnetic iron oxide (SPIO) nanoparticles were examined for viability by methyl thiazol tetrazolium (MTT) assay, proliferation by cell counting and bromodeoxyuridine (BrdU) incorporation, DNA integrity by single cell gel electrophoresis, surface antigen by flow cytometry analysis, and the expression of cytokines and genetic markers by reverse transcription-PCR and underwent adipogenic and osteogenic differentiation assessed by quantifying related specific genes expression. …”
    Get full text
    Article
  19. 1639

    Spin-Glass Behavior, Magnetic, and IR Spectroscopy Analysis of Multimetallic Compound Ni0.25Mn1.25[Fe(CN)6]·6.1H2O by Qing Lin, Xiaofang Liu, Yun He, Haifu Huang, Xingcan Shen

    Published 2015-01-01
    “…The temperature-dependent magnetic susceptibilities show the magnet transition for the compound at 8.5 K. …”
    Get full text
    Article
  20. 1640

    Coregistration of Ultrasonography and Magnetic Resonance Imaging with a Preliminary Investigation of the Spatial Colocalization of Vascular Endothelial Growth Factor Receptor 2 Expression and Tumor Perfusion in a Murine Tumor Model by Mary E. Loveless, Jennifer G. Whisenant, Kevin Wilson, Andrej Lyshchik, Tuhin K. Sinha, John C. Gore, Thomas E. Yankeelov

    Published 2009-07-01
    “…We present an ultrasonography (US)-magnetic resonance imaging (MRI) coregistration technique and examine its application in a preliminary multimodal, multiparametric study in a preclinical model of breast cancer. …”
    Get full text
    Article