-
1981
Influence of Abutment Screw-Tightening Methods on the Screw Joint: Immediate and Long-Term Stability
Published 2024-01-01“…After retightening the assemblies, a dynamic load between 20 and 200 N was applied for 105 cycles, and the postloading removal torque (PRT) (Ncm) was measured. Scanning electron microscopy (SEM) was used to observe the surface topography of the screws. …”
Get full text
Article -
1982
On the Suitability of Almond Shells for the Manufacture of a Natural Low-Cost Bioadsorbent to Remove Brilliant Green: Kinetics and Equilibrium Isotherms Study
Published 2021-01-01“…Brunauer–Emmett–Teller (BET) method, for the determination of specific surface area, Fourier-transform infrared spectroscopy (FTIR), and scanning electron microscopy (SEM) techniques were performed to characterize the ASP adsorbent. …”
Get full text
Article -
1983
Controlled bottom-up synthesis and characterization of crystalline and amorphous lead(II) coordination polymers: Sonochemical methods, structure–property relationship, and photocat...
Published 2025-03-01“…Analyses of the synthesized compounds were performed using scanning electron microscopy (SEM), powder X-ray diffraction (PXRD), FT-IR spectroscopy, and CHNS elemental analysis. …”
Get full text
Article -
1984
Silver Trimolybdate (Ag2Mo3O10.2H2O) Nanorods: Synthesis, Characterization, and Photo-Induced Antibacterial Activity under Visible-Light Irradiation
Published 2022-01-01“…The sample was characterised by scanning electron microscopy (SEM), X-ray diffraction (XRD), Fourier transform infrared (FTIR) spectroscopy, UV–Vis–NIR diffuse reflectance, thermogravimetric analysis (TGA), and differential scanning calorimeter (DSC). …”
Get full text
Article -
1985
Study of interfacial bonding properties and shrinkage deformation of cement-alkali activated gradient-structured composite in complex environments with temperature-humidity changes
Published 2025-02-01“…The early splitting strengths under the two extreme environmental effects increased and then decreased, and the maximum splitting strengths of OPCAAS were 2.66 MPa and 3.65 MPa under the temperature difference cycling and dry-wet cycling, respectively, which were 5.14% and 35.69% higher than those of OPC-AAMK, respectively. Scanning electron microscopy (SEM) characterization analysis showed that the temperature difference cycling resulted in more severe product decomposition of the AAMK cementitious material, and obvious cracks and holes appeared at the bonding interface of OPC-AAMK. …”
Get full text
Article -
1986
Rab21-Targeted Nano Drug Delivery System-Based FFPG for Efficient Paclitaxel Delivery to Inhibit Lung Cancer Progression
Published 2025-01-01“…Dynamic light scattering, zeta potential, and transmission electron microscopy were used for physical characterization. …”
Get full text
Article -
1987
In-situ/operando study of Cu-based nanocatalysts for CO2 electroreduction using electrochemical liquid cell TEM
Published 2025-01-01“…With the recent breakthrough development of high-resolution polymer electrochemical liquid cells, in-situ electrochemical liquid cell transmission electron microscopy (EC-TEM) alongside other advanced microscopy techniques, has become a powerful platform for revealing electrocatalysts restructuring at the atomic level. …”
Get full text
Article -
1988
MT1G promotes iron autophagy and inhibits the function of gastric cancer cell lines by intervening in GPX4/SQSTM1
Published 2024-11-01“…Observation of autophagy related morphological changes in cells using transmission electron microscopy. Compared with gastric mucosal cell lines, the expression of MT1G is decreased in three gastric cancer cell lines (Hgc27, MKN45 and AGS). …”
Get full text
Article -
1989
Multi-scale analysis of the progressive failure behaviour of 2.5D woven SiC/SiC composites under compression
Published 2025-01-01“…Subsequently, the microscale and mesoscale failure modes of the specimens were comprehensively characterised using X-ray computed tomography (X-CT) and scanning electron microscopy (SEM). To simulate the damage evolution process of specimens, a multi-scale finite element model representing the meso-scale structure of 2.5D SiC/SiC composites was developed, in which the proposed progressive damage method emphasising on matrix damage was adopted. …”
Get full text
Article -
1990
Atomic-scale understanding of the effects of Cr and Ti on γ′ growth kinetics in the Ni–Al-X ternary system: Diffusion couple technique and DFT study
Published 2025-03-01“…This study investigates the temporal evolution of γ′ phase in Ni–Al-X (X = Cr, Ti) system, utilizing diffusion-couple alongside aberration-corrected transmission electron microscopy to unveil atomic-scale effects. Experimental results demonstrate that Cr and Ti accelerate γ′ phase formation due to competition between lattice misfit and interdiffusion. …”
Get full text
Article -
1991
Mechanical properties and reinforcement mechanism study of sulfate saline soil solidified by polyurethane and water glass
Published 2025-07-01“…The reinforcing mechanism was revealed by scanning electron microscopy tests and mercury intrusion porosimetry. …”
Get full text
Article -
1992
Study of Crystal Structure, Lattice Strain, and Elemental Content of Natural Iron Sand Nanoparticles Synthesized by the Coprecipitation Method
Published 2025-01-01“…The results showed that based on SEM-EDX (scanning electron microscopy coupled with energy-dispersive x-ray spectroscopy) analysis, the Fe content of the raw iron sand, initially at 34.76%, increased to 45.50% following synthesis with NH4OH, indicating enhanced purity in the final product. …”
Get full text
Article -
1993
A Study on Cu Thin-Film Electroplated TiO<sub>2</sub> Photoanodes for Applications in Natural Dye-Sensitized Solar Cells
Published 2024-12-01“…Film characterization was performed using hard X-ray photoelectron spectroscopy (HAXPES), grazing incidence X-ray diffraction (GIXD), scanning electron microscopy (SEM), Fourier transform infrared (FTIR) spectroscopy, electrochemical impedance spectroscopy (EIS), ultraviolet–visible spectroscopy (UV–Vis), and photocurrent density–voltage (J–V) measurements. …”
Get full text
Article -
1994
Erythrocyte Shape Abnormalities, Membrane Oxidative Damage, and β-Actin Alterations: An Unrecognized Triad in Classical Autism
Published 2013-01-01“…Here, we investigated RBC morphology by scanning electron microscopy in patients with classical autism, that is, the predominant ASDs phenotype (age range: 6–26 years), nonautistic neurodevelopmental disorders (i.e., “positive controls”), and healthy controls (i.e., “negative controls”). …”
Get full text
Article -
1995
Mineralization Potential of Electrospun PDO-Hydroxyapatite-Fibrinogen Blended Scaffolds
Published 2012-01-01“…Scaffolds were characterized before and after mineralization via scanning electron microscopy, Alizarin Red-based assay, and modified burnout test. …”
Get full text
Article -
1996
Influence of Titanium Alloy Scaffolds on Enzymatic Defense against Oxidative Stress and Bone Marrow Cell Differentiation
Published 2020-01-01“…After 24 hours, cells plated on the scaffolds were analyzed by scanning electron microscopy (SEM). The antioxidant enzyme activity was measured 72 hours after cell plating. …”
Get full text
Article -
1997
Comparative analysis of feeding strategies and post mortem aging time on the oxidative status and color of the longissimus thoracis et lumborum muscle in Braford steers
Published 2025-01-01“…Additionally, the muscle microstructure was analyzed via scanning electron microscopy (SEM). The results demonstrated that the finishing system did not exert any discernible influence on the rates of lipid oxidation, antioxidant capacity, or muscle microstructure. …”
Get full text
Article -
1998
Biparatopic binding of ISB 1442 to CD38 in trans enables increased cell antibody density and increased avidity
Published 2025-12-01“…In solution phase, ISB 1442 forms a 2:2 complex with CD38 as determined by size-exclusion chromatography with multi-angle light scattering and electron microscopy. The predicted antibody-antigen stoichiometries at different CD38 surface densities were experimentally validated by surface plasmon resonance and cell binding assays. …”
Get full text
Article -
1999
Effect Of Magnesium Perchlorate Content on the Mechanical, Thermal Stability, and Dielectric Properties of Plasticized PMMA/PVC-g-PMMA Electrolytes
Published 2020-01-01“…Fourier transform infrared (FTIR) spectra of the electrolytes showed mutual molecular interactions between Mg(ClO4)2 and organic moieties. The scanning electron microscopy images of the GPBEs showed their wrinkled surface morphology due to their low elastic modulus and high flexibility. …”
Get full text
Article -
2000
Microscopic and Spectroscopic Investigation of (AlxGa1–X)2O3 Films: Unraveling the Impact of Growth Orientation and Aluminum Content
Published 2025-01-01“…A combination of scanning transmission electron microscopy, atom probe tomography (APT), and first‐principle calculations (DFT) is performed. …”
Get full text
Article