-
961
Data-Driven Synchronization Analysis of a Bouncing Crowd
Published 2019-01-01“…The coherence coefficients between each pair of participants in the same row or column are calculated and can be described by a lognormal distribution function. …”
Get full text
Article -
962
-
963
Effect of opercular deformity on morphological and transcriptomic profiling of gills in golden pompano (Trachinotus ovatus)
Published 2025-03-01“…Skeletal deformities in the opercular complex, jaws, and vertebral column are the most common consequences. The opercular deformity can result in the exposure of the gill chamber, which may lead to adverse effects on the gill function. …”
Get full text
Article -
964
Multiresidue Method for Quantification of Sulfonamides and Trimethoprim in Tilapia Fillet by Liquid Chromatography Coupled to Quadrupole Time-of-Flight Mass Spectrometry Using QuEC...
Published 2018-01-01“…The chromatographic separation was performed using a C18 column and 0.1% formic acid in water and acetonitrile as the mobile phase in the isocratic elution mode. …”
Get full text
Article -
965
THE AROMA OF STRAWBERRIES GROWN IN THE RIGHT-BANK FOREST-STEPPE ZONE OF UKRAINE
Published 2024-05-01“…To identify volatile compounds, an Agilent Technologies 6890 chromatograph with a 5973 mass spectrometric detector and a DB-5 chromatographic capillary column (inside diameter 0.25 mm and length 30 m) was used. …”
Get full text
Article -
966
Formulation and Development of a Water-in-Oil Emulsion-Based Luliconazole Cream: In Vitro Characterization and Analytical Method Validation by RP-HPLC
Published 2022-01-01“…In this study, an analytical C18 (4.6 mm × 25 cm), 5 μm column was used for chromatographic separation with a mixture of acetonitrile and water in the proportion of 50 : 50 v/v as the mobile phase at a flow rate of 1.0 mL/min. …”
Get full text
Article -
967
A green approach to the analysis of co-administered ampicillin/sulbactam and paracetamol in human urine
Published 2022-06-01“…The novelty of this work is the simultaneous analysis of sulbactam (SUL), ampicillin (AMP), and paracetamol (PARA) in human urine samples, using the environmentally benign RP-HPLC method. A C18 column was used in chromatographic separation using potassium dihydrogen phosphate (10 mmol L–1, pH 5)/ethanol (90 %, V/V) as the mobile phase; flow rate was 1.00 mL min–1. …”
Get full text
Article -
968
Determination of Residual Nonsteroidal Anti-Inflammatory Drugs in Aqueous Sample Using Magnetic Nanoparticles Modified with Cetyltrimethylammonium Bromide by High Performance Liqui...
Published 2014-01-01“…Methanol has been used as desorption solvent and the extracts were analysed on a reversed-phase octadecyl silica column using 0.02 M phosphate-buffer (pH = 6.02) acetonitrile (65 : 35 v/v) as the mobile phase and the effluents were measured at 202 nm with ultraviolet detector. …”
Get full text
Article -
969
Fractionation of Buckwheat Seed Phenolics and Analysis of Their Antioxidant Activity
Published 2015-12-01“…Five fractions of phenolic compounds were obtained from the extract of common buckwheat seed (Fagopyrum esculentum Moench) using Sephadex LH-20 column chromatography with methanol as a mobile phase. …”
Get full text
Article -
970
Predicted Infiltration for Sodic/Saline Soils from Reclaimed Coastal Areas: Sensitivity to Model Parameters
Published 2014-01-01“…Data was collected from column experiments in which two soils from a Chinese coastal area reclaimed in 2007 (Soil A, saline) and 1960 (Soil B, nonsaline) were used, with bulk densities of 1.4 or 1.5 g/cm3. …”
Get full text
Article -
971
Phyllosilicate-based adsorbents decorated with iron oxyhydroxides: Application for lead, chromates and selenites removal
Published 2024-01-01“…Adsorption experiments conducted in a batch and column system demonstrated good potential for purification of water contaminated with Pb2+, Cr(VI), and Se(IV). …”
Get full text
Article -
972
Simultaneous Determination of Benzene and Toluene in Pesticide Emulsifiable Concentrate by Headspace GC-MS
Published 2013-01-01“…A nonpolar fused silica Rtx-5 capillary column (30 m×0.20 mm i.d. and 0.25 μm film thickness) with temperature programming was used. …”
Get full text
Article -
973
UHPLC-UV method validation for simultaneous quantification of vitexin and isovitexin from Santalum album L. leaves
Published 2024-06-01“…The quantification procedure was performed on a Hypersil GOLD aQ Column (3 μm; 150 × 2.1 mm) at 35°C, with a mobile phase of acetonitrile (A) and and water with 0.1% formic acid (B), a flow rate of 0.3 mL/min, a detection wavelength of 336 nm, and an injection volume of 3 µL. …”
Get full text
Article -
974
A Stability-Indicating HPLC-DAD Method for Determination of Stiripentol: Development, Validation, Kinetics, Structure Elucidation and Application to Commercial Dosage Form
Published 2014-01-01“…Chromatographic separation was achieved on a Symmetry C18 column and quantification was achieved using photodiode array detector (DAD). …”
Get full text
Article -
975
Simultaneous Determination of 78 Compounds of Rhodiola rosea Extract by Supercritical CO2-Extraction and HPLC-ESI-MS/MS Spectrometry
Published 2021-01-01“…The extracts were analyzed by HPLC with MS/MS identification. 78 target analytes were isolated from Rhodiola rosea (Russia) using a series of column chromatography and mass spectrometry experiments. …”
Get full text
Article -
976
Experimental Investigation of Seawater for the Absorption of Carbon Dioxide from Ship Chimneys
Published 2024-06-01“…The second phase of experiments was carried out in a falling film column. In these experiments, the liquid side individual physical mass transfer coefficients (kL0) were determined by the oxygen (O2) desorption method for pure water and 3.5 wt% NaCl solution. …”
Get full text
Article -
977
Simultaneous Quantification of Dexpanthenol and Resorcinol from Hair Care Formulation Using Liquid Chromatography: Method Development and Validation
Published 2016-01-01“…In the current study a high performance liquid chromatographic technique has been developed using a C18 column and a mobile phase consisting of phosphate buffer of pH = 2.8 following a gradient elution. …”
Get full text
Article -
978
Effects of spinal deformities on lower limb kinematics during walking: a systematic review and meta-analysis
Published 2025-02-01“…Abstract Spinal deformities characterized by malalignment of the spinal column, including scoliosis, hyper kyphosis, and lordosis, can significantly impact lower limb kinematics, potentially leading to altered gait patterns. …”
Get full text
Article -
979
Synthesis and Spectroscopic Studies of Axially Ligated Zn(II)5,10,15,20-meso-tetra(p-chlorophenyl)porphyrin with Oxygen and Nitrogen Donors
Published 2013-01-01“…The four-coordinated zinc porphyrin accepts one axial ligand in 1 : 1 molar ratio to form five-coordinated complex, which is purified by column chromatography and characterized by IR spectra, 1H NMR, electronic absorption spectra, elemental analysis, mass spectroscopy, and TGA/DTA studies. …”
Get full text
Article -
980
Determination of Crizotinib in Mouse Tissues by LC-MS/MS and Its Application to a Tissue Distribution Study
Published 2020-01-01“…The analytes were separated on a Phenomenex Kinetex C18 (50 mm × 2.1 mm, 2.6 μm) column with gradient elution using methanol and 0.3% formic acid water solution. …”
Get full text
Article