-
841
Rapid Identification and Simultaneous Quantification of Aristolochic Acids by HPLC-DAD and Confirmations by MS in Aristolochia chilensis Using a Limited Biomass
Published 2018-01-01“…The HPLC conditions used a single mobile phase acetonitrile : water (1 : 1) acidified with 0.1% acetic acid and an isocratic elution to 1 mL·min−1. The column InertSustain C18 250 × 4.6 mm and 3 µm was used, the injection volume was 20 µL, and the time of run was reduced to 15 min. …”
Get full text
Article -
842
Analysis of Dust Reduction Characteristics of Multistage Tandem Dust Removal System
Published 2023-01-01“…As a result, an antiventuri cyclone dust collector with a scrambling column was designed. When the inlet air speed is 6 m/s, the dust removal efficiency of the improved device is 97.0%, which is 5.1% higher than that of the original device, and when the inlet air speed is 8 m/s, the dust removal efficiency of the improved device is 97.3%, which is 4.16% higher than that of the original device. …”
Get full text
Article -
843
A Simple and Improved HPLC-PDA Method for Simultaneous Estimation of Fexofenadine and Pseudoephedrine in Extended Release Tablets by Response Surface Methodology
Published 2017-01-01“…Separation was achieved on double end-capped C18 column (250 mm × 4 mm, 5 μm). In this experiment, two components of mobile phase, namely, acetonitrile (% v/v) and methanol (% v/v), were the factors whereas retention and resolution of the chromatographic peaks were the responses. …”
Get full text
Article -
844
pyScrew4Mobility: Modul Python untuk Penentuan Mobilitas Manipulator Paralel Berbasis Teori Screw
Published 2020-04-01“…The algebra methods are applied to obtain reciprocal of a screw or a screw system and basis of a screw system using null-spaces and the row/column-spaces technique, respectively. Hence, an object-oriented python module, called a pyScrew4Mobility module, is designed to realize such implementation. …”
Get full text
Article -
845
The Influence of Form and Rate on the Efficacy of Matrix-Based Fertilizers to Reduce Nutrient Leaching
Published 2009-01-01“…We tested the efficacy of matrix-based fertilizers (MBFs) to reduce NO3, NH4, and total phosphorus (TP) leaching compared to Osmocote 14-14-14, a commercial slow release fertilizer (SRF) in greenhouse column studies. The MBFs covered a range of inorganic N and P in compounds that are relatively loosely bound (MBF4) and more tightly bound compounds (MBF5) with A12(SO4)3⋅18H2O and/or Fe2(SO4)3⋅3H2O and with high ionic exchange compounds starch, chitosan, and lignin. …”
Get full text
Article -
846
Validated Reverse-Phase High-Performance Liquid Chromatography for Quantification of Furosemide in Tablets and Nanoparticles
Published 2013-01-01“…A simple, sensitive, and specific method for furosemide (FUR) analysis by reverse-phase-HPLC was developed using a Spherisorb C18 ODS 2 column. A chromatographic analysis was carried out using a mobile phase consisting of acetonitrile and 10 mM potassium phosphate buffer solution: 70 : 30 (v/v) at pH 3.85, at a flow rate of 1 mL·min−1. …”
Get full text
Article -
847
Different Stability-Indicating Chromatographic Techniques for the Determination of Netobimin
Published 2012-01-01“…Method (A) was an HPLC method, performed on C18 column using acetonitrile/methanol/0.01 M potassium dihydrogen phosphate (56 : 14 : 30 by volume) as a mobile phase with a flow rate of 0.5 mL/min. …”
Get full text
Article -
848
RP-HPLC Method for the Determination of Cinitapride in the Presence of its Degradation Products in Bulk Drug
Published 2010-01-01“…Chromatography was recorded on an Intersil ODS-3 column using mixture of acetonitrile and phosphate buffer, pH adjusted to 6.7 in the ratio (70:30 v/v) as the mobile phase at the rate of 1.0 mL/min with detection at 260 nm. …”
Get full text
Article -
849
Rapid, Validated UPLC-MS/MS Method for Determination of Glibenclamide in Rat Plasma
Published 2018-01-01“…Glibenclamide and glimepiride were eluted on C18 column (Acquity UPLC®BEH). Mobile phase consisting of acetonitrile (0.1% formic acid) and water (0.1% formic acid) was pumped in binary gradient mode at flow rate of 150 μL/min. …”
Get full text
Article -
850
A Fast and Validated HPLC Method for the Simultaneous Analysis of Five 5-HT3 Receptor Antagonists via the Quantitative Analysis of Multicomponents by a Single Marker
Published 2021-01-01“…Chromatographic separation was achieved using a C18 column (150 mm × 4.6 mm, 5.0 μm), and the mobile phase was composed of acetonitrile-0.05 mol·L−1 potassium dihydrogen phosphate (pH 4.0) (25 : 75) at a flow rate of 1.0 mL·min−1 and detection wavelengths of 307 nm (ondansetron, azasetron, ramosetron), 302 nm (granisetron), and 285 nm (tropisetron). …”
Get full text
Article -
851
The thermal structure of small and shallow Arctic Fennoscandian lakes
Published 2025-12-01“…Additionally, we emphasize the critical role of lake location, geography, and morphology, and particularly altitude, lake size, and water column transparency, in determining changes in stratification and mixing dynamics, overshadowing the influence of lake depth. …”
Get full text
Article -
852
Combinational Circuits Testing Based on Hsiao Codes with Self-Dual Check Functions
Published 2025-01-01“…These signs indicate that the functions (there are functions that describe check bits) belong to the class of self-dual Boolean functions and also belong to the codewords of Hsiao codes (these are codes with an odd column of weights). The authors have established that all check functions can be self-dual for a certain number of the Hsiao codes’ data symbols. …”
Get full text
Article -
853
Microbiological and Physicochemical Characterization of Hospital Effluents before and after Treatment with Two Types of Sawdust
Published 2019-01-01“…The aim of this study is to suggest an effective solution for their treatment. Column filtration is an adequate method to reduce the pollutant load which makes it possible to have a rate of abatement of 97% and 79% by filtering the pollutant material using sawdust of catia and red sawdust, respectively, with a filter bed height equal to 13 cm. …”
Get full text
Article -
854
Purification of Anti-Mycobacterium tuberculosis MPT64 Immunoglobulin-Y from Egg-Yolk Supernatant Using Thiophilic Adsorption Chromatography
Published 2024-03-01“…The purification of IgY anti-MPT64 was achieved by initial PEG lipid precipitation, then an optimized purification by varying the gradient concentration of elution buffer into five steps gradient (0-20, 20-40, 40-60, 60-80, and 80-100%v/v) for three injection column volume (CV) each and two steps gradient (0-50 and 50-100%v/v) in eight CV for each concentration. …”
Get full text
Article -
855
Preparation of Ginsenoside Rg3 and Protection against H2O2-Induced Oxidative Stress in Human Neuroblastoma SK-N-SH Cells
Published 2014-01-01“…The aim of this study is to evaluate the protection of ginsenoside Rg3 against oxidative stress in human neuroblastoma SK-N-SH cells. 20(R)-ginsenoside Rg3 (20(R)-Rg3) and 20(S)-ginsenoside Rg3 (20(S)-Rg3) were prepared by the method of chemical degradation and column chromatography, and the structure of the two compounds was characterized by 1H-NMR and 13C-NMR spectroscopy. …”
Get full text
Article -
856
Fast and Simple LC-MS/MS Method for Rifampicin Quantification in Human Plasma
Published 2019-01-01“…Chromatographic separation was achieved on an 1290 Infinity liquid chromatograph coupled to 6460 Triple Quadrupole operated in positive mode on a core-shell Kinetex C18 column (50 × 2.1 mm, 2.6 μm) by gradient elution using 0.1% formic acid in water and acetonitrile as a mobile phase. …”
Get full text
Article -
857
Determination of Tenacissoside G, Tenacissoside H, and Tenacissoside I in Rat Plasma by UPLC-MS/MS and Their Pharmacokinetics
Published 2023-01-01“…The determination was performed on the UPLC HSS T3 column (50 mm × 2.1 mm, 1.8 μm) with a mobile phase consisting of acetonitrile-water (containing 0.1% formic acid) and gradient elution at a flow rate of 0.4 mL/min. …”
Get full text
Article -
858
An efficient medical data encryption scheme using selective shuffling and inter-intra pixel diffusion IoT-enabled secure E-healthcare framework
Published 2025-02-01“…The CCS generates the chaotic key sequences to shuffle the medical image row-wise and column-wise. Then, selective shuffling between the cut-off points breaks the statistical relationship between the neighbouring pixels. …”
Get full text
Article -
859
Enhanced Light Scattering by Preferred Orientation Control of Ga Doped ZnO Films Prepared through MOCVD
Published 2016-01-01“…The GZO thin films exhibit the typical preferred growth orientations along the (002) crystallographic direction at deposition temperature of 400°C and SEM showed that column-like granule structure with planar surface was formed. …”
Get full text
Article -
860
A New Empirical Correlation for Estimation of EBF Steel Frame Behavior Factor under Near-Fault Earthquakes Using the Genetic Algorithm
Published 2020-01-01“…To establish different geometrical properties of models, 3−, 6−, 9−, 12−, 15, and 20− story steel EBF frames were considered with 3 different types of link beam, 3 different types of column stiffness, and 3 different types of brace slenderness. …”
Get full text
Article