-
6861
Calculation of Start-Up Time of Passive Catalytic Hydrogen Recombiner of Localization Safety System of a Nuclear Power Plant Equipped with VVER
Published 2022-02-01“…The problem is starting from a cold state since the activity of the cold catalyst is low, and the thrust is not observed until the catalyst is heated and a column of warm gas is formed inside the device. The transition from the cold state to the working state takes a certain time, during which the recombiner performance is below nominal. …”
Get full text
Article -
6862
-
6863
-
6864
-
6865
-
6866
Succinic Acid Production With Actinobacillus succinogenes –Influence of an Electric Potential on the Intercellular NADH/NAD+ Balance
Published 2025-01-01“…Using an adapted high‐performance liquid chromatography method with a Supelcosil LC‐18‐T column, it was demonstrated that NADH availability in BES, particularly during the stationary growth phase, improved by up to 1.98‐fold compared to the control. …”
Get full text
Article -
6867
-
6868
-
6869
-
6870
A Rapid and Selective LC-MS/MS Method for Quantification of Quetiapine in Human Plasma and its Application to Pharmacokinetic Study on Indian Schizophrenia Patients
Published 2011-01-01“…The eluted samples were chromatographed on a C18 column by using a 10:75:15v/v mixture of ammonium formate buffer (5 mM, pH 4.50) and acetonitrile and methanol as an isocratic mobile phase at a flow rate of 0.4 mL/min and analyzed by mass spectrometry in the multiple reaction monitoring mode using the respective [M+H]+ ions, m/z 384.3/253.2 for Quetiapine and m/z 253.1/208.1 for the internal standard. …”
Get full text
Article -
6871
-
6872
-
6873
Fast Simultaneous Determination of Eight Sudan Dyes in Chili Oil by Ultra-High-Performance Supercritical Fluid Chromatography
Published 2019-01-01“…After being diluted with dichloromethane, the analytes were separated on an Acquity UPC2 HSS C18 SB column with gradient elution using CO2 as the mobile phase and acetonitrile/methanol (v/v, 45/55, containing 0.1% formic acid) as the organic modifier. …”
Get full text
Article -
6874
-
6875
-
6876
Solvent‐Based and Matrix‐Matched Calibration Methods on Analysis of Ceftiofur Residues in Milk and Pharmaceutical Samples Using a Novel HPLC Method
Published 2024-11-01“…Methods CEF was analysed using a new HPLC method, in which separation was achieved on a C18 bonded fused‐core silica particle column by using isocratic elution; the method was optimized by testing different chromatographic conditions and validated according to the ICH Q2(R1) and United States Pharmacopeia guidelines. …”
Get full text
Article -
6877
Research on Optimal Design of Pressure Relief Blasting Parameters of Middle Rock Pillar in Near Vertical Coal Seam
Published 2022-01-01“…A presplitting blasting pressure relief technology of drilling a construction chamber in the middle of the rock column is proposed to form a buffer layer in the rock wall and effectively prevent the continuous downward movement of stress. …”
Get full text
Article -
6878
Physical and Mechanical Characteristics of Shallow Expansive Soil due to Freeze-Thaw Effect with Water Supplement
Published 2021-01-01“…Firstly, unidirectional freezing tests for expansive soil columns under three different freezing temperature gradients were carried out. …”
Get full text
Article -
6879
Determination of (4E,6E,12E)-Tetradecatriene-8,10-diyne-1,3-diyl Diacetate in Rat Plasma and Tissues by HPLC-UV Method and Their Application to a Pharmacokinetic and Tissue Distrib...
Published 2014-01-01“…A chromatography was carried out on Diamonsil C18 (250 × 4.6 mm; 5 μm) analytical column, using a mobile phase which consisted of acetonitrile and 0.1% phosphoric acid water (60 : 40, v/v) at a flow rate of 1.0 mL·min−1. …”
Get full text
Article -
6880