Showing 6,281 - 6,300 results of 7,816 for search '"column"', query time: 0.10s Refine Results
  1. 6281
  2. 6282
  3. 6283
  4. 6284
  5. 6285

    Bioanalytical Method Development and Validation of Memantine in Human Plasma by High Performance Liquid Chromatography with Tandem Mass Spectrometry: Application to Bioequivalenc... by Ravi Kumar Konda, B. R. Challa, Babu Rao Chandu, Kothapalli B. Chandrasekhar

    Published 2012-01-01
    “…Chromatography was performed on Zorbax SB-C18 (4.6×75 mm, 3.5 μm) column. Memantine (ME) and internal standard Memantine-d6(MED6) were extracted by using liquid-liquid extraction and analyzed by LC-ESI-MS/MS using multiple-reaction monitoring (MRM) mode. …”
    Get full text
    Article
  6. 6286
  7. 6287
  8. 6288
  9. 6289

    Early-Onset Neonatal Sepsis: Role of C-Reactive Protein, Micro-ESR, and Gastric Aspirate for Polymorphs as Screening Markers by Sukhdeep Kaur, Kunwarpal Singh

    Published 2021-01-01
    “…Significant values for screening tests were taken as C−reactive protein>0.6 mg/dl, micro-ESR—after 1 hour, fall in the column of blood in capillary tube was measured, and result was taken as mm fall in 1 hr, and gastric aspirate for polymorphs>5 polymorphs/HPF. …”
    Get full text
    Article
  10. 6290
  11. 6291
  12. 6292
  13. 6293

    Determination of Phthalate Plasticisers in Palm Oil Using Online Solid Phase Extraction-Liquid Chromatography (SPE-LC) by Nazarudin Ibrahim, Rozita Osman, Azmui Abdullah, Norashikin Saim

    Published 2014-01-01
    “…This system consists of two columns, C16 for the solid phase extraction (SPE) and C18 as the analytical column, and a photo diode array detector. …”
    Get full text
    Article
  14. 6294
  15. 6295
  16. 6296

    Traumatic Lumbosacral Dislocation Treated with Posterior Lumbar Interbody Fusion Using Intersomatic Cages by Katsuhiro Tofuku, Hiroaki Koga, Kazunori Yone, Setsuro Komiya

    Published 2009-01-01
    “…We believe that lumbosacral dislocation can be considered a three-column injury with an L5-S1 disc lesion, and, therefore, requires a solid circumferential segmental arthrodesis to improve fusion rate.…”
    Get full text
    Article
  17. 6297
  18. 6298

    Development of a Rapid and Sensitive HPLC Assay Method for Lenalidomide Capsules and Its Related Substances by L. Maheshwara Reddy, K. Janardhan Reddy, L. Bhaskar Reddy, P. Raveendra Reddy

    Published 2012-01-01
    “…A chromatographic method was established for the determination of lenalidomide and related substances in 10 mg and 5 mg capsules using Sunfire C-18(250×4.6 mm ID, 5 μm) HPCL column with 85:15 v/v ratio of mobile phases A (mixture of phosphoric acid buffer and 1-octane sulphonic acid sodium salt) and B(55: 45 v/v ratio of methanol and acetonitrile) at 40°C and 210 nm wave length. …”
    Get full text
    Article
  19. 6299
  20. 6300