-
381
On Topological Indices for New Classes of Benes Network
Published 2021-01-01“…In this paper, we constructed two classes of Benes network: horizontal cylindrical Benes network HCBr and vertical cylindrical Benes network obtained by identification of vertices of first rows with last row and first column with last column of Benes network, respectively. …”
Get full text
Article -
382
Improvement of the Method of Calculating Plates for Punching
Published 2024-06-01“…It should be noted that they give reliable results if certain design requirements are met (typical column sections). Along the interface line of the plate with a rectangular (square) column, supporting bending moments act in two orthogonal directions. …”
Get full text
Article -
383
Liquefaction Analysis of Soils according to the New Turkish Building Earthquake Code and Improvement against Liquefaction
Published 2019-01-01“…In addition, cards were developed to determine design parameters such as the stiffness of the columns to be used in the column formation method and the column spacing to be used for the improvement of the liquefiable soils.…”
Get full text
Article -
384
Penghitungan Beban Kritis pada Struktur Balok-Kolom Akibat Pembebanan Secara Aksial dan Lateral Berbasiskan Metode Beda Hingga
Published 2017-10-01“…This paper is aimed to determine the critical buckling load of the beam-column structures for practical applications. Firstly, the critical buckling loads is calculated numerically based on finite difference method. …”
Get full text
Article -
385
Performance Characteristics of Vortex Wind Turbines with The Computational Fluid Dynamics (CFD) Aided Simulation
Published 2025-01-01“…The innovation of the vortex lies in its unique shape and the way it harnesses energy through oscillating motion. The mast column oscillates with the wind, harnessing the von Karman vortices generated as the fluid passes through the column structure. …”
Get full text
Article -
386
A Simple Microfluidic Chip Design for Fundamental Bioseparation
Published 2014-01-01“…A microchip pressure-driven liquid chromatographic system with a packed column has been designed and fabricated by using poly(dimethylsiloxane) (PDMS). …”
Get full text
Article -
387
Sensory Function and Chronic Pain in Multiple Sclerosis
Published 2018-01-01“…Touch, joint position (dorsal column-medial lemniscus pathway), temperature sense, and pain (spinothalamic tract) were tested. …”
Get full text
Article -
388
HPLC Method Development and Validation for the Determination of Apixaban and Clopidogrel in Novel Fixed-Dose Combination Tablets
Published 2024-01-01“…., injection volume of 5 μL, and column temperature 45°C. The proposed method was linear over the level 25–200% for a concentration of APX 5 μg/ml and CLOP 75 μg/ml (R2 > 0.999). …”
Get full text
Article -
389
Timber Portal Frames vs Timber Truss-Based Systems for Residential Buildings
Published 2019-01-01“…The typical method of constructing these structures is a general timber truss and column system. The aim of this study is to look at the feasibility and economic incentive that may be gained from using a timber portal frame system, similar to the steel or timber portal frames used for larger industrial constructions, over the traditional timber truss and column arrangement. …”
Get full text
Article -
390
Preparation and Physicochemical Properties of High-purity Isomaltooligosaccharides by Sequential Simulated Moving Bed Chromatography
Published 2025-02-01“…Then, based on the single column evaluation test of preparative chromatography and the principle of material balance and the basic principle of sequential simulated moving bed. …”
Get full text
Article -
391
Determination of Benzalkonium Chloride in a Disinfectant by UV Spectrophotometry and Gas and High-Performance Liquid Chromatography: Validation, Comparison of Characteristics, and...
Published 2022-01-01“…The column temperature was kept at 30°C, and the injection volume was 10 μL. …”
Get full text
Article -
392
Structural characteristics, anticoagulant and antithrombotic mechanism of a novel polysaccharide from Rosa Chinensis Flos
Published 2023-03-01“…RCJ2-Ib was obtained through the extraction with water, precipitation with ethanol, separation with DEAE-52 column and purification with DEAE-Sepharose Fast Flow column and Sephadex G100 column. …”
Get full text
Article -
393
Experiment on Behavior of a New Connector Used in Bamboo (Timber) Frame Structure under Cyclic Loading
Published 2018-01-01“…The thickness of the hollow steel column of the connector has significant impact on the energy dissipation capacity and the strength of the connection. …”
Get full text
Article -
394
Seismic Performance of Super High-Rise Building Structure with Dual Lines of Defense Based on Response Surface Optimization Algorithm
Published 2022-01-01“…The experimental results show that the proposed analysis method has high seismic performance, and the axial compression ratio of wall and column is always stable, in which the column is always at about 0.5 and the wall is always at about 0.26, which lays a foundation for the safety performance of super high-rise building structures under earthquake.…”
Get full text
Article -
395
Experimental Study and Numerical Solution of Poly Acrylic Acid Supported Magnetite Nanoparticles Transport in a One-Dimensional Porous Media
Published 2014-01-01“…In this study, the transport of iron oxide nanoparticles (Fe3O4) stabilized with PAA in a one-dimensional porous media (column) was investigated. The slurries with concentrations of 20,100 and 500 (mg/L) were injected into the bottom of the column under hydraulic gradients of 0.125, 0.375, and 0.625. …”
Get full text
Article -
396
Influence of Foundation Rigidity on the Structural Response of Mat Foundation
Published 2021-01-01“…The variables that are considered in the analysis are the number of bays in each direction, center-to-center column spacing, mat thickness, panel aspect ratio, column cross section dimensions, soil modulus of subgrade reaction, and modulus of elasticity of concrete. …”
Get full text
Article -
397
Advanced LC-MS/MS method for selective quantification of nitrosamine impurities in Risperidone: Enhancing drug safety
Published 2025-08-01“…Chromatographic separation was achieved on an ACE-5 PFP C18 column (150 mm × 4.6 mm × 3 µm) using gradient elution with 0.2 % formic acid and methanol. …”
Get full text
Article -
398
Application of Chemically Modified and Unmodified Waste Biological Sorbents in Treatment of Wastewater
Published 2012-01-01“…Sorbents of a given particle size were packed into glass column.Then, textile wastewater that had its physicochemical parameters previously determined was eluted into each glass column and a contact time of 60 and 120 mins was allowed before analysis. …”
Get full text
Article -
399
Compressive Imaging of Moving Object Based on Linear Array Sensor
Published 2016-01-01“…The method uses a higher sampling frequency and a traditional algorithm to recover the image through a column-by-column process. During the compressive sampling stage, the output values of the linear array sensor are multiplied by a coefficient that is a measurement matrix element, and then the measurement value can be acquired by adding all the multiplication values together. …”
Get full text
Article -
400
Removal of Heavy Metals from Steel Making Waste Water by Using Electric Arc Furnace Slag
Published 2012-01-01“…Adsorption experiments were carried out by electric arc furnace slag (EAFS) in a fixed-bed column mode. The raw wastewater did not meet the standard B limitations, having high values of BOD, COD, TSS, Iron, Zinc, Manganese and Copper. …”
Get full text
Article