-
1281
Quantitative Evaluation of the Effectiveness of Erbium Glass Laser Therapy for Acne Scars
Published 2025-01-01“…Improvements in texture roughness and pigmentation contributed to a visually coherent skin surface. Conclusions: Fractional erbium glass laser therapy effectively ameliorates the appearance of atrophic acne scars by increasing skin density, reducing dermal depressions, and improving texture and pigmentation uniformity. …”
Get full text
Article -
1282
Simulation investigation of a Ka-band phase-locked klystron-type coaxial relativistic Cherenkov generator
Published 2025-01-01“…To achieve coherent power combination of Ka-band high-power microwave (HPM), a phase-locked klystron-type coaxial relativistic Cherenkov generator (PKC-RCG), which combines the advantageous characteristics of weak dimensional sensitivity of RCG and low input power ratio of relativistic triaxial klystron amplifier (TKA), is proposed and investigated in this paper. …”
Get full text
Article -
1283
Determination of Ischemia Onset Based on Automatically Generated Spectralis SD-OCT Values in Acute Central Retinal Artery Occlusion
Published 2021-01-01“…By manually measuring the relative retinal thickness increase (RRTI) in comparison to the contralateral eye based on optical coherence tomography (OCT), ischemia onset within the past 4.5 hours could be determined with 100% sensitivity and 94.3% specificity. …”
Get full text
Article -
1284
Evaluation of Agreement between HRT III and iVue OCT in Glaucoma and Ocular Hypertension Patients
Published 2015-01-01“…To determine the agreement between Moorfields Regression Analysis (MRA), Glaucoma Probability Score (GPS) of Heidelberg retinal tomograph (HRT III), and peripapillary nerve fibers thickness by iVue Optical Coherence Tomography (OCT). Methods. 72 eyes with ocular hypertension or primary open angle glaucoma (POAG) were included in the study: 54 eyes had normal visual fields (VF) and 18 had VF damage. …”
Get full text
Article -
1285
Evaluation of Navigated Laser Photocoagulation (Navilas 577+) for the Treatment of Refractory Diabetic Macular Edema
Published 2018-01-01“…Best-corrected visual acuity (BCVA) and spectral-domain optical coherence tomography (OCT) parameters were measured at baseline, 1, 3, and 6 months, and final visit. …”
Get full text
Article -
1286
MULTICRITERIA EVALUATION OF SUSTAINABILITY IN LAST-MILE LOGISTICS: A REVIEW
Published 2024-11-01“…Future research could delve deeper into the weighting process among criteria to elucidate the coherence between stated goals and actual decisions. …”
Get full text
Article -
1287
Prevalence and associated factors of epiretinal membrane using spectralis OCT in Fujian Eye Study
Published 2025-02-01“….), physical and ophthalmological examinations with height, weight, systolic blood pressure (SBP), diastolic blood pressure (DBP), heart rate (HR), refraction, intraocular pressure (IOP), slit lamp, nonmydriatic fundus photograph and spectralis optical coherence tomography (OCT) imaging. Nonmydriatic fundus photograph and Spectralis OCT were used to assess ERM according to a standardised protocol. …”
Get full text
Article -
1288
Evolution in optical molecular imaging techniques guided nerve imaging from 2009 to 2023: a bibliometric and visualization analysis
Published 2025-01-01“…The main cluster of keywords in this field includes “axonal regeneration,” “mouse,” and “optical coherence tomography.”ConclusionThis bibliometric investigation offers a comprehensive portrayal of the structure of knowledge and the progression patterns, presents an all-encompassing synthesis of findings, discerns and illustrates the forefront within OMI guided nerve imaging for the first time. …”
Get full text
Article -
1289
Improvements of Decision Support Systems for Public Administrations via a Mechanism of Co-creation of Value
Published 2015-04-01“…The comparison step is useful to understand if employees perform roles that are coherent with their own professional profiles. The proposed approach has been experimented on a small test case and the results show that its objective evaluation represents an improvement for a decision support system for the re-organization of Italian Public Administrations where, unfortunately often, people are engaged in activities that are not so close to their competences.…”
Get full text
Article -
1290
Predictors of Endothelial Cell Loss after Phacoemulsification for the Treatment of Primary Angle Closure
Published 2019-01-01“…In this prospective case series, ECD was evaluated by noncontact specular microscopy and biometric parameters by both noncontact optical biometry and anterior segment optical coherence tomography, preoperatively and at 12 months after surgery. …”
Get full text
Article -
1291
Influence of Gd alloying and ultrasonic vibration hybrid treatment on the microstructures, mechanical properties and strengthening mechanisms of Al/Mg interface by compound casting
Published 2025-03-01“…The Mg2Si particles, Al2Gd and Al8Mn4Gd precipitates were dispersed and refined. The coherent relationships among Mg2Si, Al12Mg17 and δ-Mg as well as the Gd contained precipitates and Al12Mg17 were revealed. …”
Get full text
Article -
1292
Choroidal and Retinal Thickness of Highly Myopic Eyes with Early Stage of Myopic Chorioretinopathy: Tessellation
Published 2018-01-01“…RT and CT were quantified using optical coherence tomography with enhanced depth imaging (EDI-OCT). …”
Get full text
Article -
1293
The Significant Effects of Threshold Selection for Advancing Nitrogen Use Efficiency in Whole Genome of Bread Wheat
Published 2025-01-01“…There are several ways to address this problem, including the family‐wise error rate and false discovery rate (FDR), raw and adjusted p‐value(s), consideration of threshold coherence and consonance, and the properties of proportional hypothesis tests in the threshold definition. …”
Get full text
Article -
1294
Accelerated Corneal Collagen Cross-Linking Using Topography-Guided UV-A Energy Emission: Preliminary Clinical and Morphological Outcomes
Published 2016-01-01“…Uncorrected (UDVA) and corrected (CDVA) distance visual acuity, topography, in vivo confocal microscopy (IVCM), and anterior segment optic coherence tomography (AS-OCT) were evaluated preoperatively and at the 1, 3, 6, and 12 months postoperatively. …”
Get full text
Article -
1295
A method for monitoring three dimensional surface deformation in mining areas combining SBAS-InSAR, GNSS and probability integral method
Published 2025-01-01“…This method leverages high-coherence points in mining areas and GNSS data from vegetation-covered regions to invert the parameters required by PIM, thus obtaining three-dimensional surface deformation results. …”
Get full text
Article -
1296
One Year Outcomes and Stability of a Novel Scleral Anchored Intraocular Lens
Published 2021-01-01“…Patients were evaluated preoperatively and at 1, 3, 6, and 12 months after surgery by best-corrected distance visual acuity (BCVA) assessment, intraocular pressure (IOP) measurement, corneal specular microscopy, and optical coherence tomography (OCT) of both the macula and anterior segment. …”
Get full text
Article -
1297
Hierarchical forecasting of causes of death with trend breaks in mortality modeling: Kenyan case
Published 2025-01-01“…To address these challenges, the study aims to determine and incorporate trend breaks among individual causes of death and coherently forecast them by applying the bottom-up hierarchical forecasting approach for life insurance models. …”
Get full text
Article -
1298
Systematic review and meta‑analysis of factors predicting postoperative lung function after lung cancer resection
Published 2024-07-01“…The I2 value was computed as a metric of coherence among studies, while funnel plots and the Begg test were used to evaluate the likelihood of publication bias. …”
Get full text
Article -
1299
Drift-Alfvén wave turbulence induced particle and heat transport in I-mode pedestal plasmas
Published 2025-01-01“…In this work, most of the weakly coherent mode (WCM) characteristics and the level of transport coefficients observed in I-mode pedestal plasmas of C-Mod are reproduced theoretically. …”
Get full text
Article -
1300
Evidence-based Algorithms for Free Deep Inferior Epigastric Perforator Flap Salvage in Autologous Breast Reconstruction
Published 2025-01-01“…Algorithms 2 (venous congestion) and 3 (vascular thrombosis) provide specific intraoperative strategies surrounding mechanical decompression, pedicle exposure, assessment and extraction of thrombosis, identification and use of alternative recipient vessels, and the usage of intraoperative thrombolytics. Conclusions:. A coherent and stepwise approach to DIEP flap compromise in breast reconstruction was developed. …”
Get full text
Article