Showing 1 - 8 results of 8 for search '"X-ray tube"', query time: 0.08s Refine Results
  1. 1
  2. 2
  3. 3

    Assessment of scattered and leakage radiation from ultra-portable X-ray systems in chest imaging: An independent study. by Leonie E Paulis, Roald S Schnerr, Jarred Halton, Zhi Zhen Qin, Arlene Chua

    Published 2025-01-01
    “…Additional calculations including leakage radiation were conducted at a typical radiographer position (i.e., behind the X-ray tube), with a correction factor for wearing a lead apron. …”
    Get full text
    Article
  4. 4

    X-Ray Phase-Contrast Imaging with Three 2D Gratings by Ming Jiang, Christopher Lee Wyatt, Ge Wang

    Published 2008-01-01
    “…Recently, based on the Talbot effect, groundbreaking work was reported using 1D gratings for X-ray phase-contrast imaging with a hospital-grade X-ray tube instead of a synchrotron or microfocused source. …”
    Get full text
    Article
  5. 5

    Applying Energy-Dispersive X-Ray Fluorescence Analysis to Detect Tungsten Inclusions in Nuclear Fuel Rod End Plug TIG Welds by Runqiu Gu, Jianfeng Cheng, Wanchang Lai, Guangxi Wang

    Published 2021-01-01
    “…Then, we constructed an experimental device that uses a CdTe detector with an X-ray tube. The results showed that the relative standard deviation of the net count rate of tungsten K-series characteristic X-rays [W (Kα)] was 1.46%, and the optimum parameters are a tube voltage of 150 kV and current of 0.5 mA. …”
    Get full text
    Article
  6. 6

    ESTIMATION OF ENTRANCE SURFACE DOSE (ESD) AS A DOSE PROFILE FOR PATIENTS UNDERGOING RADIOGRAPHY EXAMINATION BASED ON TUBE OUTPUT MEASUREMENT by Risalatul Latifah, Muhammad Rosyid, Firdy Yuana, Achmad Hidayat

    Published 2020-11-01
    “…The ESD was estimated from the measurements of the X-ray tube output and recorded exposure factors.  Results: The ESD value varied from 0.002 to 0.41 mGy. …”
    Get full text
    Article
  7. 7

    Occupational Radiation Exposure during Endoscopic Retrograde Cholangiopancreatography and Usefulness of Radiation Protective Curtains by Tomoyuki Minami, Tamito Sasaki, Masahiro Serikawa, Michihiro Kamigaki, Masanobu Yukutake, Takashi Ishigaki, Yasutaka Ishii, Teruo Mouri, Satoshi Yoshimi, Akinori Shimizu, Tomofumi Tsuboi, Keisuke Kurihara, Yumiko Tatsukawa, Eisuke Miyaki, Kazuaki Chayama

    Published 2014-01-01
    “…Use of radiation protective curtains mounted to the X-ray tube was determined randomly for each procedure, and radiation doses were measured with electronic pocket dosimeters placed outside the protective apron. …”
    Get full text
    Article
  8. 8

    ANAXAM @ TOMCAT 2.0: easy access to cutting-edge tomographic microscopy for industry by Margie P. Olbinado, Vladimir Novak, Christian Gruenzweig, Anne Bonnin, Federica Marone, Christian Matthias Schlepuetz, Goran Lovric, Marco Stampanoni

    Published 2025-02-01
    “…For almost two decades, TOMCAT has been offering its cutting-edge tomographic microscopy capabilities to various industries in need of non-destructive, non-invasive, volumetric, and functional material characterization beyond what is currently possible with conventional X-ray tubes [2]. Five years ago, PSI (together with two Swiss institutes and the Canton of Aargau in Switzerland) has co-founded ANAXAM – a technology transfer center that facilitates the use of advanced analytical methods at large-scale facilities such as the SLS for industrial applications. …”
    Get full text
    Article