321
Sonication: A Valuable Technique for Diagnosis and Treatment of Periprosthetic Joint Infections
Published 2013-01-01“…Methods. Explanted prosthesis components for suspected infection were placed into a tank containing sterile Ringer's solution and sonicated for 1 minute at 40 kHz. …”
Get full text
Article -
322
Floating-embedded stems reduce tibial stress shielding in total knee revision arthroplasty
Published 2025-01-01“…Typically, revision of a primary TKA is done from a bicondylar surface replacement to a stem-anchored prosthesis, which, due to higher stress-shielding, have a shorter survival time than non-stem-anchored systems. …”
Get full text
Article -
323
Reinforcement of PMMA Denture Base Material with a Mixture of ZrO2 Nanoparticles and Glass Fibers
Published 2019-01-01“…The maximum flexural strength (94.05 ± 6.95 MPa) and impact strength (3.89 ± 0.46 kJ/m2) were obtained with PMMA (2.5%)/nano-ZrO2 + 2.5% GF mixtures and could be used for removable prosthesis fabrication.…”
Get full text
Article -
324
Development of Acute Inflammatory Demyelinating Polyneuropathy 11 Days after Spinal Surgery: A Case Report and Literature Review
Published 2021-01-01“…We diagnosed acute inflammatory demyelinating polyradiculoneuropathy by a nerve conduction study, which showed findings of demyelination without cerebrospinal fluid analysis because of a spinal prosthesis. Although anti-GM1 and anti-GalNAc-GD1a antibodies were positive, the patient was clinically diagnosed with acute inflammatory demyelinating polyradiculoneuropathy (a subtype of GBS), not acute motor axonal neuropathy. …”
Get full text
Article -
325
Mechanisms Predisposing Penile Fracture and Long-Term Outcomes on Erectile and Voiding Functions
Published 2014-01-01“…Six (14.3%) patients had urethral injury and two (4.8%) had erectile dysfunction, treated by penile prosthesis and PDE-5i. No patient showed urethral fistula, voiding deterioration, penile nodule/curve or pain. …”
Get full text
Article -
326
Inferior outcome of stand-alone short versus long tibial stem in revision total knee arthroplasty. A retrospective comparative study with minimum 2 year follow-up
Published 2025-01-01“…Patients receiving mega prosthesis or implants associated with sleeves or cones were excluded. …”
Get full text
Article -
327
Impaction bone grafting for acetabular bone defects replacement in revision hip arthroplasty: biomechanical aspects
Published 2024-12-01“…The leading role in long-term survival of the prosthesis installed using impaction bone grafting is given to the mechanical properties of the graft. …”
Get full text
Article -
328
Low-cost male urogenital simulator for penile implant surgery training: a 3D printing approach
Published 2025-01-01“…Trainees, averaging three per simulator, practiced corporotomy, dilation, measurement, penile prosthesis, and scrotal pump placement under expert guidance. …”
Get full text
Article -
329
The effect of cigarette smoking and heated tobacco products on different denture materials; an in vitro study
Published 2025-02-01“…Abstract Purpose This study compares the effect of conventional cigarette smoke versus heated tobacco on the discoloration, surface roughness, and bacterial colonization of different oral prosthesis materials. Materials and methods A total of one hundred and twenty disc-shaped samples made of four different denture base materials were prepared to represent different denture bases to assess the surface roughness and biofilm formation; group (CA): conventional heat-cured acrylic resin (Acrostone, Egypt), group (FA): flexible acrylic resin (Valplast International Corp, USA), group (TA): heat-cured acrylic resin reinforced with titanium nanoparticles (TA nanoparticles, Nanogate, Egypt), and group (PA): 3D printed acrylic resin (Nexdent, The Netherlands). …”
Get full text
Article -
330
Implant-Supported Rehabilitation Using GBR Combined with Bone Graft on a Reconstructed Maxilla with the Fibula Free Flap
Published 2019-01-01“…A fixed implant-supported prosthesis with a custom-milled titanium bar screwed to the implants was made. …”
Get full text
Article -
331
Simultaneous Debridement and Titanium Mesh Reconstruction in Patients with Compound Depressed Skull Fracture: A Retrospective Descriptive Study
Published 2025-01-01“…Clinicoradiological follow-up was conducted, and outcomes in terms of surgical site infection, titanium mesh exposure, and rejection of the prosthesis were evaluated. Data collected from patients were checked, entered, and analysed using Microsoft Excel, and results were described in percentages. …”
Get full text
Article -
332
Acute haemodynamic impact of transcatheter aortic valve implantation in patients with severe aortic stenosis
Published 2022-06-01“…Conclusions Left heart catheterization performed immediately before and after prosthesis release offers a unique insight in the assessment of LV adaptation to severe AS and the impact of TAVI on LV, catching changes in indexes of intrinsic contractility and myocardial relaxation. …”
Get full text
Article -
333
Supra-Annular Versus Intra-Annular Self-Expanding Valves in Small Aortic Annulus: A Propensity Score-Matched Study
Published 2025-01-01“…Despite the larger indexed effective orifice area with SAVs (median 1.0 vs. 0.8 cm2/m2, p = 0.001), we did not find statistically significant differences between the groups in terms of residual mean gradients >20 mmHg (0.0 vs. 2.3%, p = 0.155), and severe prosthesis-patient mismatch (2.3 vs. 5.8%, p = 0.390). …”
Get full text
Article -
334
Therapeutic Potential of Targeting Ferroptosis in Periprosthetic Osteolysis Induced by Ultra-High-Molecular-Weight Polyethylene Wear Debris
Published 2025-01-01“…Mechanistically, wear debris released from the articulating surfaces of a prosthesis initiates local inflammation and several modes of regulated cell death programs, such as ferroptosis, which represents a promising therapeutic target in various chronic inflammatory diseases. …”
Get full text
Article -
335
Artificial intelligence-based, non-invasive assessment of the central aortic pressure in adults after operative or interventional treatment of aortic coarctation
Published 2025-01-01“…Comparing PBP and CABP in the entire collective, significant differences were found for CABP in relation to the procedure performed, with higher values in patients after prosthesis interposition as their last treatment (p<0.05).Conclusion AI-PWA provides valuable insights into cardiovascular stress in CoA patients, beyond PBP measurements. …”
Get full text
Article