-
1441
Medialization of shaft of humerus to provide medial buttress and prevent varus collapse in 3- and 4-part proximal humerus fractures: review of the surgical technique
Published 2025-02-01“…Conclusion: Despite limitations, this technique offers a biomechanically sound approach to enhance fixation stability, potentially improving the outcomes in proximal humerus fractures without the need for any additional fibular grafting procedures.…”
Get full text
Article -
1442
A Change in the Classical Order of Setting of Porous Metal Augments with Locked Cups in Hip Revision Surgery: Technical Note and Case Report
Published 2022-01-01“…The interlocking mechanism offers an additional biomechanical stability and thus may allow us to place the cup first in the desired position with a less demanding technique. …”
Get full text
Article -
1443
Cattle on the rocks: Understanding cattle mobility, diet, and seasonality in the Iberian Peninsula. The Middle Neolithic site of Cova de les Pixarelles (Tavertet, Osona).
Published 2025-01-01“…Previous research on the cattle bone assemblage from Cova de les Pixarelles has included comprehensive archaeozoological, palaeopathological, and biomechanical analyses-an innovative, integrative approach in Mediterranean archaeology that offers an exceptional level of biographical detail. …”
Get full text
Article -
1444
A Comparative Study on Fixation of Unstable Lateral End Clavicle Fractures with Tightrope and Endobutton by Transcoracoid and Subcoracoid Cerclage Techniques
Published 2024-12-01“…However subcoracoid technique may be considered superior in terms of better biomechanical strength, less complications, and lower cost.…”
Get full text
Article -
1445
Treadmill belt accelerations may not accurately replicate kinematic responses to tripping on an obstacle in older people.
Published 2025-01-01“…Smaller trunk displacement, step lengths, toe clearance and no falls on the treadmill indicate treadmill belt accelerations may not accurately simulate the biomechanical challenge of obstacle-induced trips in older people.…”
Get full text
Article -
1446
Advances in tissue engineering of peripheral nerve and tissue innervation – a systematic review
Published 2025-02-01“…Natural biomaterials possess important cues required for cell-material interaction and closely resemble native tissue in terms of biomechanical, geometrical and chemical composition. …”
Get full text
Article -
1447
Intraocular Pressure Measurement Using Ocular Response Analyzer, Dynamic Contour Tonometer, and Scheimpflug Analyzer Corvis ST
Published 2019-01-01“…All tonometry devices showed a good agreement of biomechanical corrected IOP values with GAT-IOPc. As no influence of CCT on IOPcc, DCT-IOP, and bIOP was detectable, the used correction algorithms appear to be appropriate in these tonometers in the clinical setting. …”
Get full text
Article -
1448
Contribution of Glycosaminoglycans to the Microstructural Integrity of Fibrillar and Fiber Crimps in Tendons and Ligaments
Published 2010-01-01“…The biomechanical roles of both tendons and ligaments are fulfilled by the extracellular matrix of these tissues. …”
Get full text
Article -
1449
Causal associations between iron levels in subcortical brain regions and psychiatric disorders: a Mendelian randomization study
Published 2025-01-01“…The observed bidirectional trends between subcortical iron levels and psychiatric disorders, indicate the importance of the underlying biomechanical interactions between brain iron regulation and these disorders.…”
Get full text
Article -
1450
Oxidative imbalance as a co-player in jaw functional limitations and biopsychosocial profile in patients with temporomandibular disorder—myofascial pain with referral
Published 2025-01-01“…IntroductionTemporomandibular disorders have a multifactorial etiology including biological, biomechanical, neuromuscular, and biopsychosocial factors. …”
Get full text
Article -
1451
Comparative Assessment of Functional Recovery Following Dynamic Hip Screw Plate versus Proximal Femoral Nail Fixation in the Management of Unstable Trochanteric Fractures of the Fe...
Published 2024-12-01“…DHS is cost-effective and user-friendly whereas PFN, though biomechanically superior, is a relatively new entrant. …”
Get full text
Article -
1452
Does the 2D Frontal Plane Projection Angle Predict Frontal Plane Knee Moments during Stepping, Landing, and Change of Direction Tasks?
Published 2022-12-01“…# Background Although dynamic knee valgus can be visually identified using the 2D frontal plane projection angle (FPPA), the validity of the FPPA in terms of predicting frontal plane knee kinematics has been questioned. The biomechanical utility of the FPPA may lie in its ability to predict frontal plane knee moments…”
Get full text
Article -
1453
Spinal mobilization force-time characteristics: A scoping literature review.
Published 2023-01-01“…While some studies quantify the biomechanical (kinetic) parameters of SMob, interpretation of findings is difficult due to poor reporting of methodological details. …”
Get full text
Article -
1454
Current developments in robotic assistance technology for total knee arthroplasty: a comprehensive overview
Published 2025-01-01“…The inevitable human factor in conventional total knee arthroplasty (TKA) frequently results in poor positioning of the prosthesis during the reconstruction of the lower limb's biomechanical axis. This can lead to severe postoperative pain, accelerated wear of the prosthesis, early loosening, and other problems in the affected knee, which has always been a primary concern for orthopaedic surgeons. …”
Get full text
Article -
1455
Noncontact Knee Ligament Injury Prevention Screening in Netball: A Clinical Commentary with Clinical Practice Suggestions for Community-Level Players
Published 2021-06-01“…Thus, high-risk landing events that have the biomechanical potential for injury occur frequently. …”
Get full text
Article -
1456
A Dynamic Finite Element Model of Knee Joint Based on Gait Analysis
Published 2016-06-01“…Objective:Combined with a static finite element model of knee joint and the gait data, a dynamic finite element (FE) model was established to simulate the stress change within the knee joint during level walking, aiming to provide an objective outcome measurement from biomechanical perspectives.Methods:Knee MRI images of a male and a female volunteers were scanned, four FE models were built by using Mimics, Geomagic, Ansys software. …”
Get full text
Article -
1457
Systematic review of machine learning applications using nonoptical motion tracking in surgery
Published 2025-01-01Get full text
Article -
1458
Spondylolisthesis and Scoliosis Progression and Associated Revision Rates Following Bilateral Lumbar Spine Microscopic Decompression
Published 2025-01-01“…Although the optimal extent of decompression remains a critical consideration, limited evidence-based guidelines define the threshold for instrumented fusion to maintain biomechanical stability. Existing studies suggest that unilateral LSMD generally does not result in iatrogenic instability. …”
Get full text
Article -
1459
Antibacterial effectiveness of different final irrigation activation techniques.
Published 2023-12-01“…Methods: Fifty-five single-rooted extracted mandibular premolars were decoronated to have a length of 12 mm, instrumented biomechanically with protaper Next up to size X3. After sterilization, five roots were selected as negative controls and the remaining teeth were inoculated with E. faecalis and incubated for 48 hr and at 37 ºC. …”
Get full text
Article -
1460
An In-Vitro Comparison of Effects of Passive Ultrasonic Irrigation with Various Concentrations of Peracetic Acid, Citric Acid, Sodium Hypochlorite, and Ethylene Diamine Tetra Aceti...
Published 2024-07-01“…Canals were irrigated, followed by filling up with Ca(OH)₂ after biomechanical preparation. The samples were divided into seven groups: Group 1: Control (positive); Group 2: Control (negative); Group 3: 5 ml of 17% EDTA + PUI; Group 4: 5 ml of 3 % NaOCl+ PUI; Group 5: 5 ml of 0.5% PAA + PUI; Group 6: 5 ml of 1% PAA + PUI; Group 7: 10% CA + PUI. …”
Get full text
Article