A Nomogram utilizing ECG P-wave parameters to predict recurrence risk following catheter ablation in paroxysmal atrial fibrillation

Highlights Abnormal changes in P-wave parameters indicative of atrial electrical remodeling often manifest earlier than changes in other indicators reflecting atrial structural remodeling in paroxysmal atrial fibrillation. Preoperative absolute values of Maximum P Wave Duration, P Wave Dispersion, a...

Full description

Saved in:
Bibliographic Details
Main Authors: Li-juan Yu, Xue-Hai Chen, Zhe Xu, Ke-Zeng Gong, Fei-Long Zhang
Format: Article
Language:English
Published: BMC 2025-01-01
Series:Journal of Cardiothoracic Surgery
Subjects:
Online Access:https://doi.org/10.1186/s13019-024-03335-0
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832585399358193664
author Li-juan Yu
Xue-Hai Chen
Zhe Xu
Ke-Zeng Gong
Fei-Long Zhang
author_facet Li-juan Yu
Xue-Hai Chen
Zhe Xu
Ke-Zeng Gong
Fei-Long Zhang
author_sort Li-juan Yu
collection DOAJ
description Highlights Abnormal changes in P-wave parameters indicative of atrial electrical remodeling often manifest earlier than changes in other indicators reflecting atrial structural remodeling in paroxysmal atrial fibrillation. Preoperative absolute values of Maximum P Wave Duration, P Wave Dispersion, and P Wave Terminal Force of V1, as well as postoperative absolute values of Maximum P Wave Duration, P Wave Duration, P Wave Dispersion, P Wave Terminal Force of V1, and P Wave Area, demonstrate strong predictive value for recurrence risk of paroxysmal atrial fibrillation after Catheter Ablation. The nomogram model based on P-wave parameters before and after catheter ablation exhibits notably strong predictive performance and offers significant clinical benefits.
format Article
id doaj-art-ff78ca09c7c14ee9a47d43303199ce57
institution Kabale University
issn 1749-8090
language English
publishDate 2025-01-01
publisher BMC
record_format Article
series Journal of Cardiothoracic Surgery
spelling doaj-art-ff78ca09c7c14ee9a47d43303199ce572025-01-26T12:51:52ZengBMCJournal of Cardiothoracic Surgery1749-80902025-01-0120111310.1186/s13019-024-03335-0A Nomogram utilizing ECG P-wave parameters to predict recurrence risk following catheter ablation in paroxysmal atrial fibrillationLi-juan Yu0Xue-Hai Chen1Zhe Xu2Ke-Zeng Gong3Fei-Long Zhang4Department of Cardiology, Fujian Medical University Union Hospital, Fujian Heart Medical Center, Fujian Institute of Coronary Heart Disease, Fujian Clinical Medical Research Center for Heart and Macrovascular DiseaseDepartment of Cardiology, Fujian Medical University Union Hospital, Fujian Heart Medical Center, Fujian Institute of Coronary Heart Disease, Fujian Clinical Medical Research Center for Heart and Macrovascular DiseaseDepartment of Cardiology, Fujian Medical University Union Hospital, Fujian Heart Medical Center, Fujian Institute of Coronary Heart Disease, Fujian Clinical Medical Research Center for Heart and Macrovascular DiseaseDepartment of Cardiology, Fujian Medical University Union Hospital, Fujian Heart Medical Center, Fujian Institute of Coronary Heart Disease, Fujian Clinical Medical Research Center for Heart and Macrovascular DiseaseDepartment of Cardiology, Fujian Medical University Union Hospital, Fujian Heart Medical Center, Fujian Institute of Coronary Heart Disease, Fujian Clinical Medical Research Center for Heart and Macrovascular DiseaseHighlights Abnormal changes in P-wave parameters indicative of atrial electrical remodeling often manifest earlier than changes in other indicators reflecting atrial structural remodeling in paroxysmal atrial fibrillation. Preoperative absolute values of Maximum P Wave Duration, P Wave Dispersion, and P Wave Terminal Force of V1, as well as postoperative absolute values of Maximum P Wave Duration, P Wave Duration, P Wave Dispersion, P Wave Terminal Force of V1, and P Wave Area, demonstrate strong predictive value for recurrence risk of paroxysmal atrial fibrillation after Catheter Ablation. The nomogram model based on P-wave parameters before and after catheter ablation exhibits notably strong predictive performance and offers significant clinical benefits.https://doi.org/10.1186/s13019-024-03335-0Catheter ablationElectronic cardiogramNomogram modelP-wave parametersParoxysmal atrial fibrillationRecurrent atrial fibrillation
spellingShingle Li-juan Yu
Xue-Hai Chen
Zhe Xu
Ke-Zeng Gong
Fei-Long Zhang
A Nomogram utilizing ECG P-wave parameters to predict recurrence risk following catheter ablation in paroxysmal atrial fibrillation
Journal of Cardiothoracic Surgery
Catheter ablation
Electronic cardiogram
Nomogram model
P-wave parameters
Paroxysmal atrial fibrillation
Recurrent atrial fibrillation
title A Nomogram utilizing ECG P-wave parameters to predict recurrence risk following catheter ablation in paroxysmal atrial fibrillation
title_full A Nomogram utilizing ECG P-wave parameters to predict recurrence risk following catheter ablation in paroxysmal atrial fibrillation
title_fullStr A Nomogram utilizing ECG P-wave parameters to predict recurrence risk following catheter ablation in paroxysmal atrial fibrillation
title_full_unstemmed A Nomogram utilizing ECG P-wave parameters to predict recurrence risk following catheter ablation in paroxysmal atrial fibrillation
title_short A Nomogram utilizing ECG P-wave parameters to predict recurrence risk following catheter ablation in paroxysmal atrial fibrillation
title_sort nomogram utilizing ecg p wave parameters to predict recurrence risk following catheter ablation in paroxysmal atrial fibrillation
topic Catheter ablation
Electronic cardiogram
Nomogram model
P-wave parameters
Paroxysmal atrial fibrillation
Recurrent atrial fibrillation
url https://doi.org/10.1186/s13019-024-03335-0
work_keys_str_mv AT lijuanyu anomogramutilizingecgpwaveparameterstopredictrecurrenceriskfollowingcatheterablationinparoxysmalatrialfibrillation
AT xuehaichen anomogramutilizingecgpwaveparameterstopredictrecurrenceriskfollowingcatheterablationinparoxysmalatrialfibrillation
AT zhexu anomogramutilizingecgpwaveparameterstopredictrecurrenceriskfollowingcatheterablationinparoxysmalatrialfibrillation
AT kezenggong anomogramutilizingecgpwaveparameterstopredictrecurrenceriskfollowingcatheterablationinparoxysmalatrialfibrillation
AT feilongzhang anomogramutilizingecgpwaveparameterstopredictrecurrenceriskfollowingcatheterablationinparoxysmalatrialfibrillation
AT lijuanyu nomogramutilizingecgpwaveparameterstopredictrecurrenceriskfollowingcatheterablationinparoxysmalatrialfibrillation
AT xuehaichen nomogramutilizingecgpwaveparameterstopredictrecurrenceriskfollowingcatheterablationinparoxysmalatrialfibrillation
AT zhexu nomogramutilizingecgpwaveparameterstopredictrecurrenceriskfollowingcatheterablationinparoxysmalatrialfibrillation
AT kezenggong nomogramutilizingecgpwaveparameterstopredictrecurrenceriskfollowingcatheterablationinparoxysmalatrialfibrillation
AT feilongzhang nomogramutilizingecgpwaveparameterstopredictrecurrenceriskfollowingcatheterablationinparoxysmalatrialfibrillation