Performance improvement of transcritical vapor generator by a novel double-heated annular configuration

A novel double-heated annular configuration is proposed for the vapor generator of transcritical CO2 power cycle. The idea originated from that an annulus is more resistant to the deterioration of supercritical heat transfer than a circular tube, and in this work attempts were made on adjusting the...

Full description

Saved in:
Bibliographic Details
Main Authors: Yue Pan, Yuling Zhai, Zhouhang Li, Nan Hu
Format: Article
Language:English
Published: Elsevier 2025-02-01
Series:Case Studies in Thermal Engineering
Subjects:
Online Access:http://www.sciencedirect.com/science/article/pii/S2214157X25000425
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832573259520933888
author Yue Pan
Yuling Zhai
Zhouhang Li
Nan Hu
author_facet Yue Pan
Yuling Zhai
Zhouhang Li
Nan Hu
author_sort Yue Pan
collection DOAJ
description A novel double-heated annular configuration is proposed for the vapor generator of transcritical CO2 power cycle. The idea originated from that an annulus is more resistant to the deterioration of supercritical heat transfer than a circular tube, and in this work attempts were made on adjusting the heating mode to potentially further improve the thermal efficiency. Numerical results from the present well-validated model show that in forced convection flow, the introduction of outside heating surprisingly increase the heat transfer coefficient at the inner side, with a maximum relative rise of 17 % to that with only inner heating. This enhancement owes to the more favorable radial profiles of fluid thermophysical properties, with specific heat and Prandtl number near the inner side being significantly increased by the outer heating. In mixed convection flow, the double-side heating improves the inside heat transfer when the outside heat flux is below 40 % of the critical heat flux in circular tubes, otherwise it may impair heat transfer, the extent of which depends on the specific operating conditions and geometric parameters. As the outside heat flux increases, wall temperatures at both annular sides gradually evolve into a similar profile to that of circular tubes. However, even when both sides are subjected to the critical heat flux, the peak wall temperatures are still 2–30 K lower than those of circular tubes. The heat transfer deterioration is not exacerbated even at the worst scenario, demonstrating the superior anti-deterioration performance of the double-heated annular configuration. Overall, the novel configuration can effectively improve supercritical heat transfer once designed as recommended, substantiating itself as a feasible option for transcritical heat exchangers.
format Article
id doaj-art-feb748ca38a04095add77d9ab68a60e9
institution Kabale University
issn 2214-157X
language English
publishDate 2025-02-01
publisher Elsevier
record_format Article
series Case Studies in Thermal Engineering
spelling doaj-art-feb748ca38a04095add77d9ab68a60e92025-02-02T05:27:27ZengElsevierCase Studies in Thermal Engineering2214-157X2025-02-0166105782Performance improvement of transcritical vapor generator by a novel double-heated annular configurationYue Pan0Yuling Zhai1Zhouhang Li2Nan Hu3Engineering Research Center of Metallurgical Energy Conservation and Emission Reduction, Ministry of Education, Kunming University of Science and Technology, Kunming, Yunnan, 650093, ChinaEngineering Research Center of Metallurgical Energy Conservation and Emission Reduction, Ministry of Education, Kunming University of Science and Technology, Kunming, Yunnan, 650093, ChinaEngineering Research Center of Metallurgical Energy Conservation and Emission Reduction, Ministry of Education, Kunming University of Science and Technology, Kunming, Yunnan, 650093, China; Corresponding author.School of Energy and Power Engineering, Changchun Institute of Technology, Changchun, 130012, China; Corresponding author.A novel double-heated annular configuration is proposed for the vapor generator of transcritical CO2 power cycle. The idea originated from that an annulus is more resistant to the deterioration of supercritical heat transfer than a circular tube, and in this work attempts were made on adjusting the heating mode to potentially further improve the thermal efficiency. Numerical results from the present well-validated model show that in forced convection flow, the introduction of outside heating surprisingly increase the heat transfer coefficient at the inner side, with a maximum relative rise of 17 % to that with only inner heating. This enhancement owes to the more favorable radial profiles of fluid thermophysical properties, with specific heat and Prandtl number near the inner side being significantly increased by the outer heating. In mixed convection flow, the double-side heating improves the inside heat transfer when the outside heat flux is below 40 % of the critical heat flux in circular tubes, otherwise it may impair heat transfer, the extent of which depends on the specific operating conditions and geometric parameters. As the outside heat flux increases, wall temperatures at both annular sides gradually evolve into a similar profile to that of circular tubes. However, even when both sides are subjected to the critical heat flux, the peak wall temperatures are still 2–30 K lower than those of circular tubes. The heat transfer deterioration is not exacerbated even at the worst scenario, demonstrating the superior anti-deterioration performance of the double-heated annular configuration. Overall, the novel configuration can effectively improve supercritical heat transfer once designed as recommended, substantiating itself as a feasible option for transcritical heat exchangers.http://www.sciencedirect.com/science/article/pii/S2214157X25000425Transcritical CO2 power cycleVapor generatorDouble-heated annular channelSupercritical heat transfer
spellingShingle Yue Pan
Yuling Zhai
Zhouhang Li
Nan Hu
Performance improvement of transcritical vapor generator by a novel double-heated annular configuration
Case Studies in Thermal Engineering
Transcritical CO2 power cycle
Vapor generator
Double-heated annular channel
Supercritical heat transfer
title Performance improvement of transcritical vapor generator by a novel double-heated annular configuration
title_full Performance improvement of transcritical vapor generator by a novel double-heated annular configuration
title_fullStr Performance improvement of transcritical vapor generator by a novel double-heated annular configuration
title_full_unstemmed Performance improvement of transcritical vapor generator by a novel double-heated annular configuration
title_short Performance improvement of transcritical vapor generator by a novel double-heated annular configuration
title_sort performance improvement of transcritical vapor generator by a novel double heated annular configuration
topic Transcritical CO2 power cycle
Vapor generator
Double-heated annular channel
Supercritical heat transfer
url http://www.sciencedirect.com/science/article/pii/S2214157X25000425
work_keys_str_mv AT yuepan performanceimprovementoftranscriticalvaporgeneratorbyanoveldoubleheatedannularconfiguration
AT yulingzhai performanceimprovementoftranscriticalvaporgeneratorbyanoveldoubleheatedannularconfiguration
AT zhouhangli performanceimprovementoftranscriticalvaporgeneratorbyanoveldoubleheatedannularconfiguration
AT nanhu performanceimprovementoftranscriticalvaporgeneratorbyanoveldoubleheatedannularconfiguration