Effects of Baffle Height and Baffle Location on Heat Transfer and Flow Profiles in a Baffled Duct: A CFD Analysis
CFD analysis of flow and heat transfer characteristics in a baffled duct is reported. The baffle locations (s=0.05H–0.40H), flow paths (V-apex directing Downstream or VD and V-apex directing Upstream or VU), and baffle heights (b=0.05H–0.30H) are investigated in the laminar flow regime with the Reyn...
Saved in:
Main Authors: | Amnart Boonloi, Withada Jedsadaratanachai |
---|---|
Format: | Article |
Language: | English |
Published: |
Wiley
2022-01-01
|
Series: | Modelling and Simulation in Engineering |
Online Access: | http://dx.doi.org/10.1155/2022/3698887 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Similar Items
-
Heat Transfer Potentiality and Flow Behavior in a Square Duct Fitted with Double-Inclined Baffles: A Numerical Analysis
by: Amnart Boonloi, et al.
Published: (2021-01-01) -
Case Studies on Enhanced Heat Transfer in a Square Duct with Modified V-Shaped Ribs (MVR): A CFD Analysis
by: Amnart Boonloi, et al.
Published: (2022-01-01) -
Mixed and Forced Convection Heat Transfer in Baffled Channels: A Brief Review
by: Rabah Henniche, et al.
Published: (2025-05-01) -
Effect of Flow Attack Angle for V-Wavy Plate on Flow and Heat Transfer in a Square Channel Heat Exchanger
by: Amnart Boonloi, et al.
Published: (2018-01-01) -
Coupling and Shielding Properties of the Baffle in ICP System
by: Jozef Brcka, et al.
Published: (2011-01-01)