Characterization of Soft Contact Lens Fitting Using Ultra-Long Scan Depth Optical Coherence Tomography

Objectives. To evaluate the centration and movement of soft contact lenses and to verify the repeatability of two repeated measurements of the lens centration and movement using ultra-long scan depth optical coherence tomography (UL-OCT). Methods. A 1-day Acuvue® Define™ lens was tested on both eyes...

Full description

Saved in:
Bibliographic Details
Main Authors: Lele Cui, Ming Li, Meixiao Shen, Fan Lu, Jianhua Wang
Format: Article
Language:English
Published: Wiley 2017-01-01
Series:Journal of Ophthalmology
Online Access:http://dx.doi.org/10.1155/2017/5763172
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832562299370471424
author Lele Cui
Ming Li
Meixiao Shen
Fan Lu
Jianhua Wang
author_facet Lele Cui
Ming Li
Meixiao Shen
Fan Lu
Jianhua Wang
author_sort Lele Cui
collection DOAJ
description Objectives. To evaluate the centration and movement of soft contact lenses and to verify the repeatability of two repeated measurements of the lens centration and movement using ultra-long scan depth optical coherence tomography (UL-OCT). Methods. A 1-day Acuvue® Define™ lens was tested on both eyes of 10 subjects (5 males and 5 females; mean age, 31.6 years). The centration and blink-induced movement of the contact lens were measured using UL-OCT at 5 min and 30 min after insertion. The measurements were repeated once at each checkpoint. Results. Good repeatability was found in the lens centration and movement between the two repeated measurements at either checkpoint. The values of the lens movement were 0.457 ± 0.248 mm and 0.402 ± 0.229 mm at 5 min and decreased to 0.197 ± 0.065 mm and 0.211 ± 0.110 mm at 30 min after insertion for the right and left eyes, respectively (P<0.05). Conclusions. The custom-built UL-OCT presented good repeatability of centration and movement in Define lenses at 5 min and 30 min after insertion. Most of the lenses were centered temporal and inferior to the cornea during the first 30 min wearing period. Compared with 5 min after insertion, the lens was centered better and exhibited less movement at 30 min.
format Article
id doaj-art-f70e04eeee03475e9fa8216772691e02
institution Kabale University
issn 2090-004X
2090-0058
language English
publishDate 2017-01-01
publisher Wiley
record_format Article
series Journal of Ophthalmology
spelling doaj-art-f70e04eeee03475e9fa8216772691e022025-02-03T01:23:01ZengWileyJournal of Ophthalmology2090-004X2090-00582017-01-01201710.1155/2017/57631725763172Characterization of Soft Contact Lens Fitting Using Ultra-Long Scan Depth Optical Coherence TomographyLele Cui0Ming Li1Meixiao Shen2Fan Lu3Jianhua Wang4School of Ophthalmology and Optometry, Wenzhou Medical University, Wenzhou, Zhejiang, ChinaSchool of Ophthalmology and Optometry, Wenzhou Medical University, Wenzhou, Zhejiang, ChinaSchool of Ophthalmology and Optometry, Wenzhou Medical University, Wenzhou, Zhejiang, ChinaSchool of Ophthalmology and Optometry, Wenzhou Medical University, Wenzhou, Zhejiang, ChinaDepartment of Ophthalmology, Bascom Palmer Eye Institute, University of Miami, Miami, FL, USAObjectives. To evaluate the centration and movement of soft contact lenses and to verify the repeatability of two repeated measurements of the lens centration and movement using ultra-long scan depth optical coherence tomography (UL-OCT). Methods. A 1-day Acuvue® Define™ lens was tested on both eyes of 10 subjects (5 males and 5 females; mean age, 31.6 years). The centration and blink-induced movement of the contact lens were measured using UL-OCT at 5 min and 30 min after insertion. The measurements were repeated once at each checkpoint. Results. Good repeatability was found in the lens centration and movement between the two repeated measurements at either checkpoint. The values of the lens movement were 0.457 ± 0.248 mm and 0.402 ± 0.229 mm at 5 min and decreased to 0.197 ± 0.065 mm and 0.211 ± 0.110 mm at 30 min after insertion for the right and left eyes, respectively (P<0.05). Conclusions. The custom-built UL-OCT presented good repeatability of centration and movement in Define lenses at 5 min and 30 min after insertion. Most of the lenses were centered temporal and inferior to the cornea during the first 30 min wearing period. Compared with 5 min after insertion, the lens was centered better and exhibited less movement at 30 min.http://dx.doi.org/10.1155/2017/5763172
spellingShingle Lele Cui
Ming Li
Meixiao Shen
Fan Lu
Jianhua Wang
Characterization of Soft Contact Lens Fitting Using Ultra-Long Scan Depth Optical Coherence Tomography
Journal of Ophthalmology
title Characterization of Soft Contact Lens Fitting Using Ultra-Long Scan Depth Optical Coherence Tomography
title_full Characterization of Soft Contact Lens Fitting Using Ultra-Long Scan Depth Optical Coherence Tomography
title_fullStr Characterization of Soft Contact Lens Fitting Using Ultra-Long Scan Depth Optical Coherence Tomography
title_full_unstemmed Characterization of Soft Contact Lens Fitting Using Ultra-Long Scan Depth Optical Coherence Tomography
title_short Characterization of Soft Contact Lens Fitting Using Ultra-Long Scan Depth Optical Coherence Tomography
title_sort characterization of soft contact lens fitting using ultra long scan depth optical coherence tomography
url http://dx.doi.org/10.1155/2017/5763172
work_keys_str_mv AT lelecui characterizationofsoftcontactlensfittingusingultralongscandepthopticalcoherencetomography
AT mingli characterizationofsoftcontactlensfittingusingultralongscandepthopticalcoherencetomography
AT meixiaoshen characterizationofsoftcontactlensfittingusingultralongscandepthopticalcoherencetomography
AT fanlu characterizationofsoftcontactlensfittingusingultralongscandepthopticalcoherencetomography
AT jianhuawang characterizationofsoftcontactlensfittingusingultralongscandepthopticalcoherencetomography