Combined Effect of a Locking Plate and Teriparatide for Incomplete Atypical Femoral Fracture: Two Case Reports of Curved Femurs
In surgical treatment for atypical femoral fractures (AFFs), reconstruction nail fixation is recommended for both complete and incomplete fractures. Although it has been reported that AFF is affected by many factors, The ASBMR Task Force 2013 Revised Case Definition of AFFs states that a curved femu...
Saved in:
Main Authors: | , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Wiley
2015-01-01
|
Series: | Case Reports in Orthopedics |
Online Access: | http://dx.doi.org/10.1155/2015/213614 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1832548989467099136 |
---|---|
author | Hiroyuki Tsuchie Naohisa Miyakoshi Tomio Nishi Hidekazu Abe Toyohito Segawa Yoichi Shimada |
author_facet | Hiroyuki Tsuchie Naohisa Miyakoshi Tomio Nishi Hidekazu Abe Toyohito Segawa Yoichi Shimada |
author_sort | Hiroyuki Tsuchie |
collection | DOAJ |
description | In surgical treatment for atypical femoral fractures (AFFs), reconstruction nail fixation is recommended for both complete and incomplete fractures. Although it has been reported that AFF is affected by many factors, The ASBMR Task Force 2013 Revised Case Definition of AFFs states that a curved femur is often seen in Asian patients. It is sometimes difficult to insert a nail into a femur in incomplete AFF patients with severely curved femurs. We report two incomplete bisphosphonate-related AFF patients with marked femoral curvatures treated by locking plates and teriparatide, showing early bone unions and favorable long-term outcomes. |
format | Article |
id | doaj-art-f6d9f228464146739d3bc1a527e6d322 |
institution | Kabale University |
issn | 2090-6749 2090-6757 |
language | English |
publishDate | 2015-01-01 |
publisher | Wiley |
record_format | Article |
series | Case Reports in Orthopedics |
spelling | doaj-art-f6d9f228464146739d3bc1a527e6d3222025-02-03T06:12:36ZengWileyCase Reports in Orthopedics2090-67492090-67572015-01-01201510.1155/2015/213614213614Combined Effect of a Locking Plate and Teriparatide for Incomplete Atypical Femoral Fracture: Two Case Reports of Curved FemursHiroyuki Tsuchie0Naohisa Miyakoshi1Tomio Nishi2Hidekazu Abe3Toyohito Segawa4Yoichi Shimada5Ugo Municipal Hospital, 44-5 Otomichi, Nishomonai, Ugo 012-1131, JapanDepartment of Orthopedic Surgery, Akita University Graduate School of Medicine, 1-1-1 Hondo, Akita 010-8543, JapanUgo Municipal Hospital, 44-5 Otomichi, Nishomonai, Ugo 012-1131, JapanUgo Municipal Hospital, 44-5 Otomichi, Nishomonai, Ugo 012-1131, JapanUgo Municipal Hospital, 44-5 Otomichi, Nishomonai, Ugo 012-1131, JapanDepartment of Orthopedic Surgery, Akita University Graduate School of Medicine, 1-1-1 Hondo, Akita 010-8543, JapanIn surgical treatment for atypical femoral fractures (AFFs), reconstruction nail fixation is recommended for both complete and incomplete fractures. Although it has been reported that AFF is affected by many factors, The ASBMR Task Force 2013 Revised Case Definition of AFFs states that a curved femur is often seen in Asian patients. It is sometimes difficult to insert a nail into a femur in incomplete AFF patients with severely curved femurs. We report two incomplete bisphosphonate-related AFF patients with marked femoral curvatures treated by locking plates and teriparatide, showing early bone unions and favorable long-term outcomes.http://dx.doi.org/10.1155/2015/213614 |
spellingShingle | Hiroyuki Tsuchie Naohisa Miyakoshi Tomio Nishi Hidekazu Abe Toyohito Segawa Yoichi Shimada Combined Effect of a Locking Plate and Teriparatide for Incomplete Atypical Femoral Fracture: Two Case Reports of Curved Femurs Case Reports in Orthopedics |
title | Combined Effect of a Locking Plate and Teriparatide for Incomplete Atypical Femoral Fracture: Two Case Reports of Curved Femurs |
title_full | Combined Effect of a Locking Plate and Teriparatide for Incomplete Atypical Femoral Fracture: Two Case Reports of Curved Femurs |
title_fullStr | Combined Effect of a Locking Plate and Teriparatide for Incomplete Atypical Femoral Fracture: Two Case Reports of Curved Femurs |
title_full_unstemmed | Combined Effect of a Locking Plate and Teriparatide for Incomplete Atypical Femoral Fracture: Two Case Reports of Curved Femurs |
title_short | Combined Effect of a Locking Plate and Teriparatide for Incomplete Atypical Femoral Fracture: Two Case Reports of Curved Femurs |
title_sort | combined effect of a locking plate and teriparatide for incomplete atypical femoral fracture two case reports of curved femurs |
url | http://dx.doi.org/10.1155/2015/213614 |
work_keys_str_mv | AT hiroyukitsuchie combinedeffectofalockingplateandteriparatideforincompleteatypicalfemoralfracturetwocasereportsofcurvedfemurs AT naohisamiyakoshi combinedeffectofalockingplateandteriparatideforincompleteatypicalfemoralfracturetwocasereportsofcurvedfemurs AT tomionishi combinedeffectofalockingplateandteriparatideforincompleteatypicalfemoralfracturetwocasereportsofcurvedfemurs AT hidekazuabe combinedeffectofalockingplateandteriparatideforincompleteatypicalfemoralfracturetwocasereportsofcurvedfemurs AT toyohitosegawa combinedeffectofalockingplateandteriparatideforincompleteatypicalfemoralfracturetwocasereportsofcurvedfemurs AT yoichishimada combinedeffectofalockingplateandteriparatideforincompleteatypicalfemoralfracturetwocasereportsofcurvedfemurs |