According to the EN 1993-1-8 Standard, the moment resistance of end-plated connections can be calculated with the use of the component method. In this, a pair-of-force defines the moment resistance. The magnitude and the location of the compression force can be accurately identified. The tension for...

Full description

Saved in:
Bibliographic Details
Main Authors: László Radnay, Imre Kovács
Format: Article
Language:English
Published: MDPI AG 2024-11-01
Series:Buildings
Subjects:
Online Access:https://www.mdpi.com/2075-5309/14/11/3553
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:According to the EN 1993-1-8 Standard, the moment resistance of end-plated connections can be calculated with the use of the component method. In this, a pair-of-force defines the moment resistance. The magnitude and the location of the compression force can be accurately identified. The tension force part is usually the resultant of parallel forces appearing in line with the bolt rows. Following the rules of manual calculation and using a mechanical finite element model, where each component is modelled with spring elements, in some—easily identifiable—cases, leads to different force distribution. The simplifications defined in the Standard provide a longer arm for the same force, and because of this, larger moment resistance at the expense of safety. In this work, an alternative calculation method will be presented that provides the same force values in each bolt row, as the mechanical model of the connection, without constructing the finite element model.
ISSN:2075-5309