Negative Ion Beam Emittance Calculations

Computer simulations are commonly used to support design and optimisation of powerful negative ion sources for the needs of future thermonuclear reactors like e. g. ITER. The aim of the paper was to study changes of produced beam quality (described by its emittance and brightness) with the geometry...

Full description

Saved in:
Bibliographic Details
Main Authors: M. Turek, P. Węgierek
Format: Article
Language:English
Published: Belarusian National Technical University 2020-03-01
Series:Приборы и методы измерений
Online Access:https://pimi.bntu.by/jour/article/view/638
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832543819088789504
author M. Turek
P. Węgierek
author_facet M. Turek
P. Węgierek
author_sort M. Turek
collection DOAJ
description Computer simulations are commonly used to support design and optimisation of powerful negative ion sources for the needs of future thermonuclear reactors like e. g. ITER. The aim of the paper was to study changes of produced beam quality (described by its emittance and brightness) with the geometry of the extraction system as well as extraction voltage.A two-dimensional Particle-in-Cell (PIC) method based code was applied to model Hions and electrons extraction from the ion source plasma chamber through the opening with bevelled surface. The root-meansquare emittance of the extracted beam was calculated according to Chasman and Lapostolle approach. Ion beam phase space portraits were also presented to enrich the discussion.Growth of ion (electron) beam emittance was observed both with the increasing radius of the extraction opening and the inclination of its bevelled surfaces. This degradation of beam quality is partially balanced by increasing extracted Hion current. On the other hand, increasing length of the extraction channel improves the beam quality.It was demonstrated that for wider extraction opening the Hion beam consist of two parts coming form the two different regions of the chamber. According to calculated beam brightness the optimal wall inclination was found to be near 26o in the studied case. The decrease of the beam emittance saturates for larger channel length values. In the considered case the optimal channel length was h = 1.7 mm. The evolution of ion beam emittance and brightness shows that the best beam quality is achieved for extraction voltages between 0.5 kV and 2 kV.
format Article
id doaj-art-f53e43dbdd914e11b665b40a67aae4a0
institution Kabale University
issn 2220-9506
2414-0473
language English
publishDate 2020-03-01
publisher Belarusian National Technical University
record_format Article
series Приборы и методы измерений
spelling doaj-art-f53e43dbdd914e11b665b40a67aae4a02025-02-03T11:28:28ZengBelarusian National Technical UniversityПриборы и методы измерений2220-95062414-04732020-03-01111425210.21122/2220-9506-2020-11-1-42-52503Negative Ion Beam Emittance CalculationsM. Turek0P. Węgierek1Maria Curie-Sklodowska University in LublinLublin University of TechnologyComputer simulations are commonly used to support design and optimisation of powerful negative ion sources for the needs of future thermonuclear reactors like e. g. ITER. The aim of the paper was to study changes of produced beam quality (described by its emittance and brightness) with the geometry of the extraction system as well as extraction voltage.A two-dimensional Particle-in-Cell (PIC) method based code was applied to model Hions and electrons extraction from the ion source plasma chamber through the opening with bevelled surface. The root-meansquare emittance of the extracted beam was calculated according to Chasman and Lapostolle approach. Ion beam phase space portraits were also presented to enrich the discussion.Growth of ion (electron) beam emittance was observed both with the increasing radius of the extraction opening and the inclination of its bevelled surfaces. This degradation of beam quality is partially balanced by increasing extracted Hion current. On the other hand, increasing length of the extraction channel improves the beam quality.It was demonstrated that for wider extraction opening the Hion beam consist of two parts coming form the two different regions of the chamber. According to calculated beam brightness the optimal wall inclination was found to be near 26o in the studied case. The decrease of the beam emittance saturates for larger channel length values. In the considered case the optimal channel length was h = 1.7 mm. The evolution of ion beam emittance and brightness shows that the best beam quality is achieved for extraction voltages between 0.5 kV and 2 kV.https://pimi.bntu.by/jour/article/view/638
spellingShingle M. Turek
P. Węgierek
Negative Ion Beam Emittance Calculations
Приборы и методы измерений
title Negative Ion Beam Emittance Calculations
title_full Negative Ion Beam Emittance Calculations
title_fullStr Negative Ion Beam Emittance Calculations
title_full_unstemmed Negative Ion Beam Emittance Calculations
title_short Negative Ion Beam Emittance Calculations
title_sort negative ion beam emittance calculations
url https://pimi.bntu.by/jour/article/view/638
work_keys_str_mv AT mturek negativeionbeamemittancecalculations
AT pwegierek negativeionbeamemittancecalculations