The method of line protection construction with application of IEC 61850 standard on the example of Sepam 1000+ series microprocessor terminal

The paper raises a variant of architecture of realization of logical line protection on the basis of implementation of modern technologies. The idea of development and implementation of digital substations, the core of which is the application of IEC 61850 standard, has been developing at a great...

Full description

Saved in:
Bibliographic Details
Main Authors: D. A. Davydov, M. A. Kholmov, K. I. Nikitin, M. Ya. Kletsel
Format: Article
Language:English
Published: Omsk State Technical University, Federal State Autonoumos Educational Institution of Higher Education 2024-06-01
Series:Омский научный вестник
Subjects:
Online Access:https://www.omgtu.ru/general_information/media_omgtu/journal_of_omsk_research_journal/files/arhiv/2024/%E2%84%962%20(190)%20%D0%9E%D0%9D%D0%92/87-98%20%D0%94%D0%B0%D0%B2%D1%8B%D0%B4%D0%BE%D0%B2%20%D0%94.%20%D0%90.,%20%D0%A5%D0%BE%D0%BB%D0%BC%D0%BE%D0%B2%20%D0%9C.%20%D0%90.,%20%D0%9D%D0%B8%D0%BA%D0%B8%D1%82%D0%B8%D0%BD%20%D0%9A.%20%D0%98.,%20%D0%9A%D0%BB%D0%B5%D1%86%D0%B5%D0%BB%D1%8C%20%D0%9C.%20%D0%AF..pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832544861396402176
author D. A. Davydov
M. A. Kholmov
K. I. Nikitin
M. Ya. Kletsel
author_facet D. A. Davydov
M. A. Kholmov
K. I. Nikitin
M. Ya. Kletsel
author_sort D. A. Davydov
collection DOAJ
description The paper raises a variant of architecture of realization of logical line protection on the basis of implementation of modern technologies. The idea of development and implementation of digital substations, the core of which is the application of IEC 61850 standard, has been developing at a great pace in the world. The appearance of this standard in substations opens new ways of realization of protection of electrical installations. In this article we consider the method of construction of line protection using the method of logical selectivity, and as the main terminals are considered Sepam devices series 1000+, as one of the most widely distributed devices in the electric power industry of the Russian Federation, the basic support for the standard IEC 61850.
format Article
id doaj-art-f4ce501c0ac74cb19a0e34198e4aebdc
institution Kabale University
issn 1813-8225
2541-7541
language English
publishDate 2024-06-01
publisher Omsk State Technical University, Federal State Autonoumos Educational Institution of Higher Education
record_format Article
series Омский научный вестник
spelling doaj-art-f4ce501c0ac74cb19a0e34198e4aebdc2025-02-03T09:30:41ZengOmsk State Technical University, Federal State Autonoumos Educational Institution of Higher EducationОмский научный вестник1813-82252541-75412024-06-012 (190)879810.25206/1813-8225-2024-190-87-98The method of line protection construction with application of IEC 61850 standard on the example of Sepam 1000+ series microprocessor terminalD. A. Davydov0https://orcid.org/0009-0004-2042-481XM. A. Kholmov1https://orcid.org/0000-0003-4803-7729K. I. Nikitin2M. Ya. Kletsel3Omsk State Technical UniversityOmsk State Technical UniversityOmsk State Technical UniversityToraighyrov UniversityThe paper raises a variant of architecture of realization of logical line protection on the basis of implementation of modern technologies. The idea of development and implementation of digital substations, the core of which is the application of IEC 61850 standard, has been developing at a great pace in the world. The appearance of this standard in substations opens new ways of realization of protection of electrical installations. In this article we consider the method of construction of line protection using the method of logical selectivity, and as the main terminals are considered Sepam devices series 1000+, as one of the most widely distributed devices in the electric power industry of the Russian Federation, the basic support for the standard IEC 61850.https://www.omgtu.ru/general_information/media_omgtu/journal_of_omsk_research_journal/files/arhiv/2024/%E2%84%962%20(190)%20%D0%9E%D0%9D%D0%92/87-98%20%D0%94%D0%B0%D0%B2%D1%8B%D0%B4%D0%BE%D0%B2%20%D0%94.%20%D0%90.,%20%D0%A5%D0%BE%D0%BB%D0%BC%D0%BE%D0%B2%20%D0%9C.%20%D0%90.,%20%D0%9D%D0%B8%D0%BA%D0%B8%D1%82%D0%B8%D0%BD%20%D0%9A.%20%D0%98.,%20%D0%9A%D0%BB%D0%B5%D1%86%D0%B5%D0%BB%D1%8C%20%D0%9C.%20%D0%AF..pdfdigital substationiec 61850line protectiondecentralized relay protectionlogic selectivitymicroprocessor relay protectionlocal substation networkcurrent protection
spellingShingle D. A. Davydov
M. A. Kholmov
K. I. Nikitin
M. Ya. Kletsel
The method of line protection construction with application of IEC 61850 standard on the example of Sepam 1000+ series microprocessor terminal
Омский научный вестник
digital substation
iec 61850
line protection
decentralized relay protection
logic selectivity
microprocessor relay protection
local substation network
current protection
title The method of line protection construction with application of IEC 61850 standard on the example of Sepam 1000+ series microprocessor terminal
title_full The method of line protection construction with application of IEC 61850 standard on the example of Sepam 1000+ series microprocessor terminal
title_fullStr The method of line protection construction with application of IEC 61850 standard on the example of Sepam 1000+ series microprocessor terminal
title_full_unstemmed The method of line protection construction with application of IEC 61850 standard on the example of Sepam 1000+ series microprocessor terminal
title_short The method of line protection construction with application of IEC 61850 standard on the example of Sepam 1000+ series microprocessor terminal
title_sort method of line protection construction with application of iec 61850 standard on the example of sepam 1000 series microprocessor terminal
topic digital substation
iec 61850
line protection
decentralized relay protection
logic selectivity
microprocessor relay protection
local substation network
current protection
url https://www.omgtu.ru/general_information/media_omgtu/journal_of_omsk_research_journal/files/arhiv/2024/%E2%84%962%20(190)%20%D0%9E%D0%9D%D0%92/87-98%20%D0%94%D0%B0%D0%B2%D1%8B%D0%B4%D0%BE%D0%B2%20%D0%94.%20%D0%90.,%20%D0%A5%D0%BE%D0%BB%D0%BC%D0%BE%D0%B2%20%D0%9C.%20%D0%90.,%20%D0%9D%D0%B8%D0%BA%D0%B8%D1%82%D0%B8%D0%BD%20%D0%9A.%20%D0%98.,%20%D0%9A%D0%BB%D0%B5%D1%86%D0%B5%D0%BB%D1%8C%20%D0%9C.%20%D0%AF..pdf
work_keys_str_mv AT dadavydov themethodoflineprotectionconstructionwithapplicationofiec61850standardontheexampleofsepam1000seriesmicroprocessorterminal
AT makholmov themethodoflineprotectionconstructionwithapplicationofiec61850standardontheexampleofsepam1000seriesmicroprocessorterminal
AT kinikitin themethodoflineprotectionconstructionwithapplicationofiec61850standardontheexampleofsepam1000seriesmicroprocessorterminal
AT myakletsel themethodoflineprotectionconstructionwithapplicationofiec61850standardontheexampleofsepam1000seriesmicroprocessorterminal
AT dadavydov methodoflineprotectionconstructionwithapplicationofiec61850standardontheexampleofsepam1000seriesmicroprocessorterminal
AT makholmov methodoflineprotectionconstructionwithapplicationofiec61850standardontheexampleofsepam1000seriesmicroprocessorterminal
AT kinikitin methodoflineprotectionconstructionwithapplicationofiec61850standardontheexampleofsepam1000seriesmicroprocessorterminal
AT myakletsel methodoflineprotectionconstructionwithapplicationofiec61850standardontheexampleofsepam1000seriesmicroprocessorterminal