Soft Tissue Dehiscence Associated with a Titanium Patient-Specific Implant: A Prosthetic Solution as an Alternative to Soft Tissue Grafting

Patients. This clinical report describes the detailed prosthodontic management of a 23-year-old male patient suffering from soft tissue complication following the placement of a 3d-printed titanium patient-specific implant. This implant was implemented simultaneously with the resection of a calcifyi...

Full description

Saved in:
Bibliographic Details
Main Authors: Sharaf Eldeen M. Abbas, Mohamed A. ELKhashab
Format: Article
Language:English
Published: Wiley 2021-01-01
Series:Case Reports in Dentistry
Online Access:http://dx.doi.org/10.1155/2021/5125375
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832551989564669952
author Sharaf Eldeen M. Abbas
Mohamed A. ELKhashab
author_facet Sharaf Eldeen M. Abbas
Mohamed A. ELKhashab
author_sort Sharaf Eldeen M. Abbas
collection DOAJ
description Patients. This clinical report describes the detailed prosthodontic management of a 23-year-old male patient suffering from soft tissue complication following the placement of a 3d-printed titanium patient-specific implant. This implant was implemented simultaneously with the resection of a calcifying cystic odontogenic tumor related to the maxillary arch. Later, soft tissue dehiscence and implant exposure were encountered with subsequent food impaction, infection, and pus discharge. The treatment plan was to fabricate removable partial denture. The prosthesis was planned to be retained by bar and clip attachment on the patient-specific implant side, while on the other side, the removable prosthesis was allowed to engage two abutments with an embrasure clasp assembly in addition to covering the palatal tissues to offer protection for the soft tissue dehiscence against food impaction. Discussion. Soft tissue dehiscence and implant exposure are among the frequently reported complications associated with the patient-specific implant. The resulting infection complicates the prognosis of the implemented implant and necessitates, in some occasions, its removal. The selection of the removable prosthesis to cover soft tissue dehiscence was a conservative alternative to the implant removal as it protects the exposed titanium surface from food impaction while maintaining the implant functionality. Conclusion. Three-year follow-up showed complete resolution of the patient’s complaints while fulfilling the patient’s aesthetic and functional demands and indicates that the use of detachable overlay prosthesis could be one of the proposed treatment options.
format Article
id doaj-art-f42672a2a46c4cc8818be7716c52ded2
institution Kabale University
issn 2090-6455
language English
publishDate 2021-01-01
publisher Wiley
record_format Article
series Case Reports in Dentistry
spelling doaj-art-f42672a2a46c4cc8818be7716c52ded22025-02-03T05:59:58ZengWileyCase Reports in Dentistry2090-64552021-01-01202110.1155/2021/5125375Soft Tissue Dehiscence Associated with a Titanium Patient-Specific Implant: A Prosthetic Solution as an Alternative to Soft Tissue GraftingSharaf Eldeen M. Abbas0Mohamed A. ELKhashab1Department of ProsthodonticsDepartment of ProsthodonticsPatients. This clinical report describes the detailed prosthodontic management of a 23-year-old male patient suffering from soft tissue complication following the placement of a 3d-printed titanium patient-specific implant. This implant was implemented simultaneously with the resection of a calcifying cystic odontogenic tumor related to the maxillary arch. Later, soft tissue dehiscence and implant exposure were encountered with subsequent food impaction, infection, and pus discharge. The treatment plan was to fabricate removable partial denture. The prosthesis was planned to be retained by bar and clip attachment on the patient-specific implant side, while on the other side, the removable prosthesis was allowed to engage two abutments with an embrasure clasp assembly in addition to covering the palatal tissues to offer protection for the soft tissue dehiscence against food impaction. Discussion. Soft tissue dehiscence and implant exposure are among the frequently reported complications associated with the patient-specific implant. The resulting infection complicates the prognosis of the implemented implant and necessitates, in some occasions, its removal. The selection of the removable prosthesis to cover soft tissue dehiscence was a conservative alternative to the implant removal as it protects the exposed titanium surface from food impaction while maintaining the implant functionality. Conclusion. Three-year follow-up showed complete resolution of the patient’s complaints while fulfilling the patient’s aesthetic and functional demands and indicates that the use of detachable overlay prosthesis could be one of the proposed treatment options.http://dx.doi.org/10.1155/2021/5125375
spellingShingle Sharaf Eldeen M. Abbas
Mohamed A. ELKhashab
Soft Tissue Dehiscence Associated with a Titanium Patient-Specific Implant: A Prosthetic Solution as an Alternative to Soft Tissue Grafting
Case Reports in Dentistry
title Soft Tissue Dehiscence Associated with a Titanium Patient-Specific Implant: A Prosthetic Solution as an Alternative to Soft Tissue Grafting
title_full Soft Tissue Dehiscence Associated with a Titanium Patient-Specific Implant: A Prosthetic Solution as an Alternative to Soft Tissue Grafting
title_fullStr Soft Tissue Dehiscence Associated with a Titanium Patient-Specific Implant: A Prosthetic Solution as an Alternative to Soft Tissue Grafting
title_full_unstemmed Soft Tissue Dehiscence Associated with a Titanium Patient-Specific Implant: A Prosthetic Solution as an Alternative to Soft Tissue Grafting
title_short Soft Tissue Dehiscence Associated with a Titanium Patient-Specific Implant: A Prosthetic Solution as an Alternative to Soft Tissue Grafting
title_sort soft tissue dehiscence associated with a titanium patient specific implant a prosthetic solution as an alternative to soft tissue grafting
url http://dx.doi.org/10.1155/2021/5125375
work_keys_str_mv AT sharafeldeenmabbas softtissuedehiscenceassociatedwithatitaniumpatientspecificimplantaprostheticsolutionasanalternativetosofttissuegrafting
AT mohamedaelkhashab softtissuedehiscenceassociatedwithatitaniumpatientspecificimplantaprostheticsolutionasanalternativetosofttissuegrafting