A Novel Tool for High-Throughput Screening of Granulocyte-Specific Antibodies Using the Automated Flow Cytometric Granulocyte Immunofluorescence Test (Flow-GIFT)
Transfusion-related acute lung injury (TRALI) is a severe complication related with blood transfusion. TRALI has usually been associated with antibodies against leukocytes. The flow cytometric granulocyte immunofluorescence test (Flow-GIFT) has been introduced for routine use when investigating pati...
Saved in:
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Wiley
2011-01-01
|
Series: | The Scientific World Journal |
Online Access: | http://dx.doi.org/10.1100/tsw.2011.20 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1832563883087233024 |
---|---|
author | Xuan Duc Nguyen Thomas Dengler Monika Schulz-Linkholt Harald Klüter |
author_facet | Xuan Duc Nguyen Thomas Dengler Monika Schulz-Linkholt Harald Klüter |
author_sort | Xuan Duc Nguyen |
collection | DOAJ |
description | Transfusion-related acute lung injury (TRALI) is a severe complication related with blood transfusion. TRALI has usually been associated with antibodies against leukocytes. The flow cytometric granulocyte immunofluorescence test (Flow-GIFT) has been introduced for routine use when investigating patients and healthy blood donors. Here we describe a novel tool in the automation of the Flow-GIFT that enables a rapid screening of blood donations. We analyzed 440 sera from healthy female blood donors for the presence of granulocyte antibodies. As positive controls, 12 sera with known antibodies against anti-HNA-1a, -b, -2a; and -3a were additionally investigated. Whole-blood samples from HNA-typed donors were collected and the test cells isolated using cell sedimentation in a Ficoll density gradient. Subsequently, leukocytes were incubated with the respective serum and binding of antibodies was detected using FITC-conjugated antihuman antibody. 7-AAD was used to exclude dead cells. Pipetting steps were automated using the Biomek NXp Multichannel Automation Workstation. All samples were prepared in the 96-deep well plates and analyzed by flow cytometry. The standard granulocyte immunofluorescence test (GIFT) and granulocyte agglutination test (GAT) were also performed as reference methods. Sixteen sera were positive in the automated Flow-GIFT, while five of these sera were negative in the standard GIFT (anti—HNA 3a, n = 3; anti—HNA-1b, n = 1) and GAT (anti—HNA-2a, n = 1). The automated Flow-GIFT was able to detect all granulocyte antibodies, which could be only detected in GIFT in combination with GAT. In serial dilution tests, the automated Flow-GIFT detected the antibodies at higher dilutions than the reference methods GIFT and GAT. The Flow-GIFT proved to be feasible for automation. This novel high-throughput system allows an effective antigranulocyte antibody detection in a large donor population in order to prevent TRALI due to transfusion of blood products. |
format | Article |
id | doaj-art-f234e8eecd864ba8ad8737da479eb070 |
institution | Kabale University |
issn | 1537-744X |
language | English |
publishDate | 2011-01-01 |
publisher | Wiley |
record_format | Article |
series | The Scientific World Journal |
spelling | doaj-art-f234e8eecd864ba8ad8737da479eb0702025-02-03T01:12:23ZengWileyThe Scientific World Journal1537-744X2011-01-011130230910.1100/tsw.2011.20A Novel Tool for High-Throughput Screening of Granulocyte-Specific Antibodies Using the Automated Flow Cytometric Granulocyte Immunofluorescence Test (Flow-GIFT)Xuan Duc Nguyen0Thomas Dengler1Monika Schulz-Linkholt2Harald Klüter3Institute of Transfusion Medicine and Immunology, Medical Faculty Mannheim, University Heidelberg, German Red-Cross Blood Service of Baden-Württemberg - Hessen, GermanyInstitute for Transfusion Medicine Baden-Baden, German Red-Cross Blood Service of Baden-Württemberg - Hessen, GermanyInstitute of Transfusion Medicine and Immunology, Medical Faculty Mannheim, University Heidelberg, German Red-Cross Blood Service of Baden-Württemberg - Hessen, GermanyInstitute of Transfusion Medicine and Immunology, Medical Faculty Mannheim, University Heidelberg, German Red-Cross Blood Service of Baden-Württemberg - Hessen, GermanyTransfusion-related acute lung injury (TRALI) is a severe complication related with blood transfusion. TRALI has usually been associated with antibodies against leukocytes. The flow cytometric granulocyte immunofluorescence test (Flow-GIFT) has been introduced for routine use when investigating patients and healthy blood donors. Here we describe a novel tool in the automation of the Flow-GIFT that enables a rapid screening of blood donations. We analyzed 440 sera from healthy female blood donors for the presence of granulocyte antibodies. As positive controls, 12 sera with known antibodies against anti-HNA-1a, -b, -2a; and -3a were additionally investigated. Whole-blood samples from HNA-typed donors were collected and the test cells isolated using cell sedimentation in a Ficoll density gradient. Subsequently, leukocytes were incubated with the respective serum and binding of antibodies was detected using FITC-conjugated antihuman antibody. 7-AAD was used to exclude dead cells. Pipetting steps were automated using the Biomek NXp Multichannel Automation Workstation. All samples were prepared in the 96-deep well plates and analyzed by flow cytometry. The standard granulocyte immunofluorescence test (GIFT) and granulocyte agglutination test (GAT) were also performed as reference methods. Sixteen sera were positive in the automated Flow-GIFT, while five of these sera were negative in the standard GIFT (anti—HNA 3a, n = 3; anti—HNA-1b, n = 1) and GAT (anti—HNA-2a, n = 1). The automated Flow-GIFT was able to detect all granulocyte antibodies, which could be only detected in GIFT in combination with GAT. In serial dilution tests, the automated Flow-GIFT detected the antibodies at higher dilutions than the reference methods GIFT and GAT. The Flow-GIFT proved to be feasible for automation. This novel high-throughput system allows an effective antigranulocyte antibody detection in a large donor population in order to prevent TRALI due to transfusion of blood products.http://dx.doi.org/10.1100/tsw.2011.20 |
spellingShingle | Xuan Duc Nguyen Thomas Dengler Monika Schulz-Linkholt Harald Klüter A Novel Tool for High-Throughput Screening of Granulocyte-Specific Antibodies Using the Automated Flow Cytometric Granulocyte Immunofluorescence Test (Flow-GIFT) The Scientific World Journal |
title | A Novel Tool for High-Throughput Screening of Granulocyte-Specific Antibodies Using the Automated Flow Cytometric Granulocyte Immunofluorescence Test (Flow-GIFT) |
title_full | A Novel Tool for High-Throughput Screening of Granulocyte-Specific Antibodies Using the Automated Flow Cytometric Granulocyte Immunofluorescence Test (Flow-GIFT) |
title_fullStr | A Novel Tool for High-Throughput Screening of Granulocyte-Specific Antibodies Using the Automated Flow Cytometric Granulocyte Immunofluorescence Test (Flow-GIFT) |
title_full_unstemmed | A Novel Tool for High-Throughput Screening of Granulocyte-Specific Antibodies Using the Automated Flow Cytometric Granulocyte Immunofluorescence Test (Flow-GIFT) |
title_short | A Novel Tool for High-Throughput Screening of Granulocyte-Specific Antibodies Using the Automated Flow Cytometric Granulocyte Immunofluorescence Test (Flow-GIFT) |
title_sort | novel tool for high throughput screening of granulocyte specific antibodies using the automated flow cytometric granulocyte immunofluorescence test flow gift |
url | http://dx.doi.org/10.1100/tsw.2011.20 |
work_keys_str_mv | AT xuanducnguyen anoveltoolforhighthroughputscreeningofgranulocytespecificantibodiesusingtheautomatedflowcytometricgranulocyteimmunofluorescencetestflowgift AT thomasdengler anoveltoolforhighthroughputscreeningofgranulocytespecificantibodiesusingtheautomatedflowcytometricgranulocyteimmunofluorescencetestflowgift AT monikaschulzlinkholt anoveltoolforhighthroughputscreeningofgranulocytespecificantibodiesusingtheautomatedflowcytometricgranulocyteimmunofluorescencetestflowgift AT haraldkluter anoveltoolforhighthroughputscreeningofgranulocytespecificantibodiesusingtheautomatedflowcytometricgranulocyteimmunofluorescencetestflowgift AT xuanducnguyen noveltoolforhighthroughputscreeningofgranulocytespecificantibodiesusingtheautomatedflowcytometricgranulocyteimmunofluorescencetestflowgift AT thomasdengler noveltoolforhighthroughputscreeningofgranulocytespecificantibodiesusingtheautomatedflowcytometricgranulocyteimmunofluorescencetestflowgift AT monikaschulzlinkholt noveltoolforhighthroughputscreeningofgranulocytespecificantibodiesusingtheautomatedflowcytometricgranulocyteimmunofluorescencetestflowgift AT haraldkluter noveltoolforhighthroughputscreeningofgranulocytespecificantibodiesusingtheautomatedflowcytometricgranulocyteimmunofluorescencetestflowgift |