Stenting as a Rescue Treatment of a Pulmonary Artery False Aneurysm Caused by Swan-Ganz Catheterization

Pulmonary vascular injury is a rare but life-threatening complication of Swan-Ganz catheterization. We report an 82-year old patient who underwent right heart catheterization by a balloon-tipped catheter because of suspected pulmonary hypertension. After deflation of the catheter in the wedge positi...

Full description

Saved in:
Bibliographic Details
Main Authors: Stefanie Keymel, Marc W. Merx, Tobias Zeus, Malte Kelm, Stephan Steiner
Format: Article
Language:English
Published: Wiley 2014-01-01
Series:Case Reports in Pulmonology
Online Access:http://dx.doi.org/10.1155/2014/893647
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832560357082660864
author Stefanie Keymel
Marc W. Merx
Tobias Zeus
Malte Kelm
Stephan Steiner
author_facet Stefanie Keymel
Marc W. Merx
Tobias Zeus
Malte Kelm
Stephan Steiner
author_sort Stefanie Keymel
collection DOAJ
description Pulmonary vascular injury is a rare but life-threatening complication of Swan-Ganz catheterization. We report an 82-year old patient who underwent right heart catheterization by a balloon-tipped catheter because of suspected pulmonary hypertension. After deflation of the catheter in the wedge position, hemoptoe appeared associated with acute respiratory insufficiency requiring respiratory support by intubation and mechanical ventilation. Pulmonary angiography showed the formation of a false aneurysm of a segment artery of the left lower lobe. Immediate interventional therapy was performed by the implantation of two coated coronary stent grafts into the injured pulmonary artery thereby excluding the false aneurysm. Bleeding was stopped by this interventional approach while antegrade blood flow was maintained. Long term follow-up after 3 months showed an effective treatment with a completely thrombotic false aneurysm. However, despite oral anticoagulation and dual antiplatelet therapy, graft patency could not be achieved after 3 months. In summary, implantation of coated stents is a feasible and safe approach for the acute and long term treatment of potentially life-threatening condition of a pulmonary artery false aneurysm while treatment to achieve long term patency of the affected vessel still remains an issue to be resolved.
format Article
id doaj-art-ee9147aad24444bea555dd93a0e41a68
institution Kabale University
issn 2090-6846
2090-6854
language English
publishDate 2014-01-01
publisher Wiley
record_format Article
series Case Reports in Pulmonology
spelling doaj-art-ee9147aad24444bea555dd93a0e41a682025-02-03T01:27:49ZengWileyCase Reports in Pulmonology2090-68462090-68542014-01-01201410.1155/2014/893647893647Stenting as a Rescue Treatment of a Pulmonary Artery False Aneurysm Caused by Swan-Ganz CatheterizationStefanie Keymel0Marc W. Merx1Tobias Zeus2Malte Kelm3Stephan Steiner4Division of Cardiology, Pneumology and Angiology, Department of Medicine, Medical Faculty, University Hospital Duesseldorf, 40225 Düsseldorf, GermanyDepartment of Cardiology, Angiology and Intensive Care Medicine, Robert Koch Hospital, 30989 Hannover, GermanyDivision of Cardiology, Pneumology and Angiology, Department of Medicine, Medical Faculty, University Hospital Duesseldorf, 40225 Düsseldorf, GermanyDivision of Cardiology, Pneumology and Angiology, Department of Medicine, Medical Faculty, University Hospital Duesseldorf, 40225 Düsseldorf, GermanyDivision of Cardiology, Pneumology and Intensive Care Medicine, Department of Medicine, St. Vincenz Hospital, Auf dem Schafsberg, 65549 Limburg an der Lahn, GermanyPulmonary vascular injury is a rare but life-threatening complication of Swan-Ganz catheterization. We report an 82-year old patient who underwent right heart catheterization by a balloon-tipped catheter because of suspected pulmonary hypertension. After deflation of the catheter in the wedge position, hemoptoe appeared associated with acute respiratory insufficiency requiring respiratory support by intubation and mechanical ventilation. Pulmonary angiography showed the formation of a false aneurysm of a segment artery of the left lower lobe. Immediate interventional therapy was performed by the implantation of two coated coronary stent grafts into the injured pulmonary artery thereby excluding the false aneurysm. Bleeding was stopped by this interventional approach while antegrade blood flow was maintained. Long term follow-up after 3 months showed an effective treatment with a completely thrombotic false aneurysm. However, despite oral anticoagulation and dual antiplatelet therapy, graft patency could not be achieved after 3 months. In summary, implantation of coated stents is a feasible and safe approach for the acute and long term treatment of potentially life-threatening condition of a pulmonary artery false aneurysm while treatment to achieve long term patency of the affected vessel still remains an issue to be resolved.http://dx.doi.org/10.1155/2014/893647
spellingShingle Stefanie Keymel
Marc W. Merx
Tobias Zeus
Malte Kelm
Stephan Steiner
Stenting as a Rescue Treatment of a Pulmonary Artery False Aneurysm Caused by Swan-Ganz Catheterization
Case Reports in Pulmonology
title Stenting as a Rescue Treatment of a Pulmonary Artery False Aneurysm Caused by Swan-Ganz Catheterization
title_full Stenting as a Rescue Treatment of a Pulmonary Artery False Aneurysm Caused by Swan-Ganz Catheterization
title_fullStr Stenting as a Rescue Treatment of a Pulmonary Artery False Aneurysm Caused by Swan-Ganz Catheterization
title_full_unstemmed Stenting as a Rescue Treatment of a Pulmonary Artery False Aneurysm Caused by Swan-Ganz Catheterization
title_short Stenting as a Rescue Treatment of a Pulmonary Artery False Aneurysm Caused by Swan-Ganz Catheterization
title_sort stenting as a rescue treatment of a pulmonary artery false aneurysm caused by swan ganz catheterization
url http://dx.doi.org/10.1155/2014/893647
work_keys_str_mv AT stefaniekeymel stentingasarescuetreatmentofapulmonaryarteryfalseaneurysmcausedbyswanganzcatheterization
AT marcwmerx stentingasarescuetreatmentofapulmonaryarteryfalseaneurysmcausedbyswanganzcatheterization
AT tobiaszeus stentingasarescuetreatmentofapulmonaryarteryfalseaneurysmcausedbyswanganzcatheterization
AT maltekelm stentingasarescuetreatmentofapulmonaryarteryfalseaneurysmcausedbyswanganzcatheterization
AT stephansteiner stentingasarescuetreatmentofapulmonaryarteryfalseaneurysmcausedbyswanganzcatheterization