FEATURES OF CALIBRATION OF INFRARED RADIOMETERS WORKING IN WINDOW OF TRANSPARENCY OF THE ATMOSPHERE 8-14 MICRONS

This article considers the possibility of using additional infrared radiometry compensators "transparent" in the operating spectral range of 8-14 μm and having radiating parameters controlled with high accuracy. This will allow a simpler way to register the radiation fluxes of the atmosphe...

Full description

Saved in:
Bibliographic Details
Main Author: A. P. Velichko
Format: Article
Language:Russian
Published: MIREA - Russian Technological University 2018-12-01
Series:Российский технологический журнал
Subjects:
Online Access:https://www.rtj-mirea.ru/jour/article/view/133
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832543395653877760
author A. P. Velichko
author_facet A. P. Velichko
author_sort A. P. Velichko
collection DOAJ
description This article considers the possibility of using additional infrared radiometry compensators "transparent" in the operating spectral range of 8-14 μm and having radiating parameters controlled with high accuracy. This will allow a simpler way to register the radiation fluxes of the atmosphere at different zenithal angles without taking into account the hardware function of the radiometer. The constant monitoring of this function is quite a difficult technical task. It is proposed to use a polyethylene film with a thickness of 10 μm as a compensator. Depending on the value of the radiation flow, a certain number of layers of such a film with constantly controlled parameters, which will be a kind of a "reference radiator", are introduced into the measuring channel in front of the radiometer. The article presents theoretical calculations based on the laws of infrared radiation propagation in the Earth's atmosphere, as well as experimental data confirming the expediency of this technique in remote sensing of the atmosphere in the "transparency window". This technique extends the dynamic range of the radiometer in the low temperature range (below 223 K), which is the sensitivity threshold of most radiometers.The temperature of the "clean" atmosphere at the zenith is much lower.
format Article
id doaj-art-edfe748dcc0141ef841fe3c6718f9042
institution Kabale University
issn 2500-316X
language Russian
publishDate 2018-12-01
publisher MIREA - Russian Technological University
record_format Article
series Российский технологический журнал
spelling doaj-art-edfe748dcc0141ef841fe3c6718f90422025-02-03T11:45:52ZrusMIREA - Russian Technological UniversityРоссийский технологический журнал2500-316X2018-12-0166556510.32362/2500-316X-2018-6-6-55-65133FEATURES OF CALIBRATION OF INFRARED RADIOMETERS WORKING IN WINDOW OF TRANSPARENCY OF THE ATMOSPHERE 8-14 MICRONSA. P. Velichko0MIREA - Russian Technological UniversityThis article considers the possibility of using additional infrared radiometry compensators "transparent" in the operating spectral range of 8-14 μm and having radiating parameters controlled with high accuracy. This will allow a simpler way to register the radiation fluxes of the atmosphere at different zenithal angles without taking into account the hardware function of the radiometer. The constant monitoring of this function is quite a difficult technical task. It is proposed to use a polyethylene film with a thickness of 10 μm as a compensator. Depending on the value of the radiation flow, a certain number of layers of such a film with constantly controlled parameters, which will be a kind of a "reference radiator", are introduced into the measuring channel in front of the radiometer. The article presents theoretical calculations based on the laws of infrared radiation propagation in the Earth's atmosphere, as well as experimental data confirming the expediency of this technique in remote sensing of the atmosphere in the "transparency window". This technique extends the dynamic range of the radiometer in the low temperature range (below 223 K), which is the sensitivity threshold of most radiometers.The temperature of the "clean" atmosphere at the zenith is much lower.https://www.rtj-mirea.ru/jour/article/view/133atmospheretransparency windowir radiometeraerosolwater vaporwavelength
spellingShingle A. P. Velichko
FEATURES OF CALIBRATION OF INFRARED RADIOMETERS WORKING IN WINDOW OF TRANSPARENCY OF THE ATMOSPHERE 8-14 MICRONS
Российский технологический журнал
atmosphere
transparency window
ir radiometer
aerosol
water vapor
wavelength
title FEATURES OF CALIBRATION OF INFRARED RADIOMETERS WORKING IN WINDOW OF TRANSPARENCY OF THE ATMOSPHERE 8-14 MICRONS
title_full FEATURES OF CALIBRATION OF INFRARED RADIOMETERS WORKING IN WINDOW OF TRANSPARENCY OF THE ATMOSPHERE 8-14 MICRONS
title_fullStr FEATURES OF CALIBRATION OF INFRARED RADIOMETERS WORKING IN WINDOW OF TRANSPARENCY OF THE ATMOSPHERE 8-14 MICRONS
title_full_unstemmed FEATURES OF CALIBRATION OF INFRARED RADIOMETERS WORKING IN WINDOW OF TRANSPARENCY OF THE ATMOSPHERE 8-14 MICRONS
title_short FEATURES OF CALIBRATION OF INFRARED RADIOMETERS WORKING IN WINDOW OF TRANSPARENCY OF THE ATMOSPHERE 8-14 MICRONS
title_sort features of calibration of infrared radiometers working in window of transparency of the atmosphere 8 14 microns
topic atmosphere
transparency window
ir radiometer
aerosol
water vapor
wavelength
url https://www.rtj-mirea.ru/jour/article/view/133
work_keys_str_mv AT apvelichko featuresofcalibrationofinfraredradiometersworkinginwindowoftransparencyoftheatmosphere814microns