A correction factor that denotes an increase of heat transfer coefficient of a corridor tube bank at longitudinal pitch decrease is widely used in educational literature. The paper shows that such inverse relationship is not confirmed by the majority of scientific investigations. Additional experime...
Saved in:
Main Author: | |
---|---|
Format: | Article |
Language: | Russian |
Published: |
Belarusian National Technical University
2009-06-01
|
Series: | Известия высших учебных заведений и энергетических объединенний СНГ: Энергетика |
Online Access: | https://energy.bntu.by/jour/article/view/498 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1832557271985422336 |
---|---|
author | A. A. Smаliak |
author_facet | A. A. Smаliak |
author_sort | A. A. Smаliak |
collection | DOAJ |
description | A correction factor that denotes an increase of heat transfer coefficient of a corridor tube bank at longitudinal pitch decrease is widely used in educational literature. The paper shows that such inverse relationship is not confirmed by the majority of scientific investigations. Additional experimental data are given in the paper. The correction factor for consideration of the influence of corridor tube bank geometrical characteristics on heat transfer is offered to be used in engineering calculations. |
format | Article |
id | doaj-art-ebe15ab076284373a2452be84ba232bd |
institution | Kabale University |
issn | 1029-7448 2414-0341 |
language | Russian |
publishDate | 2009-06-01 |
publisher | Belarusian National Technical University |
record_format | Article |
series | Известия высших учебных заведений и энергетических объединенний СНГ: Энергетика |
spelling | doaj-art-ebe15ab076284373a2452be84ba232bd2025-02-03T05:35:47ZrusBelarusian National Technical UniversityИзвестия высших учебных заведений и энергетических объединенний СНГ: Энергетика1029-74482414-03412009-06-01037277491About Influence of Corridor Tube Bank Geometry on Its Heat Transfer in Cross FlowA. A. SmаliakA correction factor that denotes an increase of heat transfer coefficient of a corridor tube bank at longitudinal pitch decrease is widely used in educational literature. The paper shows that such inverse relationship is not confirmed by the majority of scientific investigations. Additional experimental data are given in the paper. The correction factor for consideration of the influence of corridor tube bank geometrical characteristics on heat transfer is offered to be used in engineering calculations.https://energy.bntu.by/jour/article/view/498 |
spellingShingle | A. A. Smаliak About Influence of Corridor Tube Bank Geometry on Its Heat Transfer in Cross Flow Известия высших учебных заведений и энергетических объединенний СНГ: Энергетика |
title | About Influence of Corridor Tube Bank Geometry on Its Heat Transfer in Cross Flow |
title_full | About Influence of Corridor Tube Bank Geometry on Its Heat Transfer in Cross Flow |
title_fullStr | About Influence of Corridor Tube Bank Geometry on Its Heat Transfer in Cross Flow |
title_full_unstemmed | About Influence of Corridor Tube Bank Geometry on Its Heat Transfer in Cross Flow |
title_short | About Influence of Corridor Tube Bank Geometry on Its Heat Transfer in Cross Flow |
title_sort | about influence of corridor tube bank geometry on its heat transfer in cross flow |
url | https://energy.bntu.by/jour/article/view/498 |
work_keys_str_mv | AT aasmaliak aboutinfluenceofcorridortubebankgeometryonitsheattransferincrossflow |