About Influence of Corridor Tube Bank Geometry on Its Heat Transfer in Cross Flow

A correction factor that denotes an increase of heat transfer coefficient of a corridor tube bank at longitudinal pitch decrease is widely used in educational literature. The paper shows that such inverse relationship is not confirmed by the majority of scientific investigations. Additional experime...

Full description

Saved in:
Bibliographic Details
Main Author: A. A. Smаliak
Format: Article
Language:Russian
Published: Belarusian National Technical University 2009-06-01
Series:Известия высших учебных заведений и энергетических объединенний СНГ: Энергетика
Online Access:https://energy.bntu.by/jour/article/view/498
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832557271985422336
author A. A. Smаliak
author_facet A. A. Smаliak
author_sort A. A. Smаliak
collection DOAJ
description A correction factor that denotes an increase of heat transfer coefficient of a corridor tube bank at longitudinal pitch decrease is widely used in educational literature. The paper shows that such inverse relationship is not confirmed by the majority of scientific investigations. Additional experimental data are given in the paper. The correction factor for consideration of the influence of corridor tube bank geometrical characteristics on heat transfer is offered to be used in engineering calculations.
format Article
id doaj-art-ebe15ab076284373a2452be84ba232bd
institution Kabale University
issn 1029-7448
2414-0341
language Russian
publishDate 2009-06-01
publisher Belarusian National Technical University
record_format Article
series Известия высших учебных заведений и энергетических объединенний СНГ: Энергетика
spelling doaj-art-ebe15ab076284373a2452be84ba232bd2025-02-03T05:35:47ZrusBelarusian National Technical UniversityИзвестия высших учебных заведений и энергетических объединенний СНГ: Энергетика1029-74482414-03412009-06-01037277491About Influence of Corridor Tube Bank Geometry on Its Heat Transfer in Cross FlowA. A. SmаliakA correction factor that denotes an increase of heat transfer coefficient of a corridor tube bank at longitudinal pitch decrease is widely used in educational literature. The paper shows that such inverse relationship is not confirmed by the majority of scientific investigations. Additional experimental data are given in the paper. The correction factor for consideration of the influence of corridor tube bank geometrical characteristics on heat transfer is offered to be used in engineering calculations.https://energy.bntu.by/jour/article/view/498
spellingShingle A. A. Smаliak
About Influence of Corridor Tube Bank Geometry on Its Heat Transfer in Cross Flow
Известия высших учебных заведений и энергетических объединенний СНГ: Энергетика
title About Influence of Corridor Tube Bank Geometry on Its Heat Transfer in Cross Flow
title_full About Influence of Corridor Tube Bank Geometry on Its Heat Transfer in Cross Flow
title_fullStr About Influence of Corridor Tube Bank Geometry on Its Heat Transfer in Cross Flow
title_full_unstemmed About Influence of Corridor Tube Bank Geometry on Its Heat Transfer in Cross Flow
title_short About Influence of Corridor Tube Bank Geometry on Its Heat Transfer in Cross Flow
title_sort about influence of corridor tube bank geometry on its heat transfer in cross flow
url https://energy.bntu.by/jour/article/view/498
work_keys_str_mv AT aasmaliak aboutinfluenceofcorridortubebankgeometryonitsheattransferincrossflow