Automated Patient-specific Quality Assurance for Automated Segmentation of Organs at Risk in Nasopharyngeal Carcinoma Radiotherapy

Introduction Precision radiotherapy relies on accurate segmentation of tumor targets and organs at risk (OARs). Clinicians manually review automatically delineated structures on a case-by-case basis, a time-consuming process dependent on reviewer experience and alertness. This study proposes a gener...

Full description

Saved in:
Bibliographic Details
Main Authors: Yixuan Wang MD, Jiang Hu MD, Lixin Chen PhD, Dandan Zhang PhD, Jinhan Zhu PhD
Format: Article
Language:English
Published: SAGE Publishing 2025-01-01
Series:Cancer Control
Online Access:https://doi.org/10.1177/10732748251318387
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832542688587546624
author Yixuan Wang MD
Jiang Hu MD
Lixin Chen PhD
Dandan Zhang PhD
Jinhan Zhu PhD
author_facet Yixuan Wang MD
Jiang Hu MD
Lixin Chen PhD
Dandan Zhang PhD
Jinhan Zhu PhD
author_sort Yixuan Wang MD
collection DOAJ
description Introduction Precision radiotherapy relies on accurate segmentation of tumor targets and organs at risk (OARs). Clinicians manually review automatically delineated structures on a case-by-case basis, a time-consuming process dependent on reviewer experience and alertness. This study proposes a general process for automated threshold generation for structural evaluation indicators and patient-specific quality assurance (QA) for automated segmentation of nasopharyngeal carcinoma (NPC). Methods The patient-specific QA process for automated segmentation involves determining the confidence limit and error structure highlight stage. Three expert physicians segmented 17 OARs using computed tomography images of NPC and compared them using the Dice similarity coefficient, the maximum Hausdorff distance, and the mean distance to agreement. For each OAR, the 95% confidence interval was calculated as the confidence limit for each indicator. If two or more evaluation indicators (N2) or one or more evaluation indicators (N1) exceeded the confidence limits, the structure segmentation result was considered abnormal. The quantitative performances of these two methods were compared with those obtained by artificially introducing small/medium and serious errors. Results The sensitivity, specificity, balanced accuracy, and F-score values for N2 were 0.944 ± 0.052, 0.827 ± 0.149, 0.886 ± 0.076, and 0.936 ± 0.045, respectively, whereas those for N1 were 0.955 ± 0.045, 0.788 ± 0.189, 0.878 ± 0.096, and 0.948 ± 0.035, respectively. N2 and N1 had small/medium error detection rates of 97.67 ± 0.04% and 98.67 ± 0.04%, respectively, with a serious error detection rate of 100%. Conclusion The proposed automated patient-specific QA process effectively detected segmentation abnormalities, particularly serious errors. These are crucial for enhancing review efficiency and automated segmentation, and for improving physician confidence in automated segmentation.
format Article
id doaj-art-ea8454f08bf54189af52942fa1acc2a7
institution Kabale University
issn 1526-2359
language English
publishDate 2025-01-01
publisher SAGE Publishing
record_format Article
series Cancer Control
spelling doaj-art-ea8454f08bf54189af52942fa1acc2a72025-02-03T19:03:30ZengSAGE PublishingCancer Control1526-23592025-01-013210.1177/10732748251318387Automated Patient-specific Quality Assurance for Automated Segmentation of Organs at Risk in Nasopharyngeal Carcinoma RadiotherapyYixuan Wang MDJiang Hu MDLixin Chen PhDDandan Zhang PhDJinhan Zhu PhDIntroduction Precision radiotherapy relies on accurate segmentation of tumor targets and organs at risk (OARs). Clinicians manually review automatically delineated structures on a case-by-case basis, a time-consuming process dependent on reviewer experience and alertness. This study proposes a general process for automated threshold generation for structural evaluation indicators and patient-specific quality assurance (QA) for automated segmentation of nasopharyngeal carcinoma (NPC). Methods The patient-specific QA process for automated segmentation involves determining the confidence limit and error structure highlight stage. Three expert physicians segmented 17 OARs using computed tomography images of NPC and compared them using the Dice similarity coefficient, the maximum Hausdorff distance, and the mean distance to agreement. For each OAR, the 95% confidence interval was calculated as the confidence limit for each indicator. If two or more evaluation indicators (N2) or one or more evaluation indicators (N1) exceeded the confidence limits, the structure segmentation result was considered abnormal. The quantitative performances of these two methods were compared with those obtained by artificially introducing small/medium and serious errors. Results The sensitivity, specificity, balanced accuracy, and F-score values for N2 were 0.944 ± 0.052, 0.827 ± 0.149, 0.886 ± 0.076, and 0.936 ± 0.045, respectively, whereas those for N1 were 0.955 ± 0.045, 0.788 ± 0.189, 0.878 ± 0.096, and 0.948 ± 0.035, respectively. N2 and N1 had small/medium error detection rates of 97.67 ± 0.04% and 98.67 ± 0.04%, respectively, with a serious error detection rate of 100%. Conclusion The proposed automated patient-specific QA process effectively detected segmentation abnormalities, particularly serious errors. These are crucial for enhancing review efficiency and automated segmentation, and for improving physician confidence in automated segmentation.https://doi.org/10.1177/10732748251318387
spellingShingle Yixuan Wang MD
Jiang Hu MD
Lixin Chen PhD
Dandan Zhang PhD
Jinhan Zhu PhD
Automated Patient-specific Quality Assurance for Automated Segmentation of Organs at Risk in Nasopharyngeal Carcinoma Radiotherapy
Cancer Control
title Automated Patient-specific Quality Assurance for Automated Segmentation of Organs at Risk in Nasopharyngeal Carcinoma Radiotherapy
title_full Automated Patient-specific Quality Assurance for Automated Segmentation of Organs at Risk in Nasopharyngeal Carcinoma Radiotherapy
title_fullStr Automated Patient-specific Quality Assurance for Automated Segmentation of Organs at Risk in Nasopharyngeal Carcinoma Radiotherapy
title_full_unstemmed Automated Patient-specific Quality Assurance for Automated Segmentation of Organs at Risk in Nasopharyngeal Carcinoma Radiotherapy
title_short Automated Patient-specific Quality Assurance for Automated Segmentation of Organs at Risk in Nasopharyngeal Carcinoma Radiotherapy
title_sort automated patient specific quality assurance for automated segmentation of organs at risk in nasopharyngeal carcinoma radiotherapy
url https://doi.org/10.1177/10732748251318387
work_keys_str_mv AT yixuanwangmd automatedpatientspecificqualityassuranceforautomatedsegmentationoforgansatriskinnasopharyngealcarcinomaradiotherapy
AT jianghumd automatedpatientspecificqualityassuranceforautomatedsegmentationoforgansatriskinnasopharyngealcarcinomaradiotherapy
AT lixinchenphd automatedpatientspecificqualityassuranceforautomatedsegmentationoforgansatriskinnasopharyngealcarcinomaradiotherapy
AT dandanzhangphd automatedpatientspecificqualityassuranceforautomatedsegmentationoforgansatriskinnasopharyngealcarcinomaradiotherapy
AT jinhanzhuphd automatedpatientspecificqualityassuranceforautomatedsegmentationoforgansatriskinnasopharyngealcarcinomaradiotherapy