Assessment of Traffic-Related Ambient Air Particulate Matter (PM) Levels in Douala, Cameroon

A challenge in many Sub-Saharan African (SSA) cities is the absence of air quality monitoring due to the high expense and technical expertise needed. Air pollution around the world is becoming a societal problem, and developed countries have all the necessary information about the levels of most air...

Full description

Saved in:
Bibliographic Details
Main Authors: Yannick Cédric Ngangmo, Cyrille Adiang Mezoue, Cyrille Meukaleuni, Brice B. S. Wandjie, David Monkam
Format: Article
Language:English
Published: Wiley 2024-01-01
Series:Advances in Meteorology
Online Access:http://dx.doi.org/10.1155/2024/1787640
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832546167664148480
author Yannick Cédric Ngangmo
Cyrille Adiang Mezoue
Cyrille Meukaleuni
Brice B. S. Wandjie
David Monkam
author_facet Yannick Cédric Ngangmo
Cyrille Adiang Mezoue
Cyrille Meukaleuni
Brice B. S. Wandjie
David Monkam
author_sort Yannick Cédric Ngangmo
collection DOAJ
description A challenge in many Sub-Saharan African (SSA) cities is the absence of air quality monitoring due to the high expense and technical expertise needed. Air pollution around the world is becoming a societal problem, and developed countries have all the necessary information about the levels of most air pollutants; however, underdeveloped countries have inadequate information on air quality. The problem of poor air quality in many SSA countries is due to lack of information about the hazards of poor air quality, lack of monitoring equipment, and lack of measuring stations: this is the case in Cameroon. We are avoiding these problems by using portable, low-cost, low-maintenance air quality monitoring equipment, including the OC 300 dust particle laser, to observe pollution levels of particle matter levels in the PK17 Douala-Cameroon, a locality in the Central African region where no air quality data previously existed. The air quality index is very poor on the measurement days, and the color code is red. It has maximum values of about 199 for PM10 and 192 for PM2.5. The average concentration values obtained were of the order of 200.54 µg·m−3, 155.54 µg·m−3, 194.90 µg·m−3, and 194.03 µg·m−3 for PM10, respectively, on Tuesday, Thursday, Saturday, and Sunday. Regarding PM2.5, the average concentrations are 99.84 µg·m−3, 82.30 µg·m−3, 108.23 µg·m−3, and 112.97 µg·m−3, respectively, on Tuesday, Thursday, Saturday, and Sunday. A two-dimensional Gaussian model was used to estimate the particle matter concentration along each road. The nRMSE was 9% for PM10 and 12 for PM2.5, and the index-d for both particle sizes was close to 1 (0.74 for PM10 and 0.98 for PM2.5), which allows us to conclude that the calculated concentrations are the closest to the measured concentrations. The assessment reveals that most of the particulate matter during the measurement period was generated by road traffic. The concentration measured values of the pollutants are three times for PM2.5 and four times for PM10 above the recent WHO limits for daily exposure. In addition, it provides essential information on the pollution in Douala, which can be a major source of illness in the city and must be addressed.
format Article
id doaj-art-e8e7a2fe99fb4e55a5450438d82b2007
institution Kabale University
issn 1687-9317
language English
publishDate 2024-01-01
publisher Wiley
record_format Article
series Advances in Meteorology
spelling doaj-art-e8e7a2fe99fb4e55a5450438d82b20072025-02-03T07:23:45ZengWileyAdvances in Meteorology1687-93172024-01-01202410.1155/2024/1787640Assessment of Traffic-Related Ambient Air Particulate Matter (PM) Levels in Douala, CameroonYannick Cédric Ngangmo0Cyrille Adiang Mezoue1Cyrille Meukaleuni2Brice B. S. Wandjie3David Monkam4Laboratory of Fundamental PhysicsLaboratory of Fundamental PhysicsInstitut Universitaire de la CôteLaboratory of Fundamental PhysicsLaboratory of Fundamental PhysicsA challenge in many Sub-Saharan African (SSA) cities is the absence of air quality monitoring due to the high expense and technical expertise needed. Air pollution around the world is becoming a societal problem, and developed countries have all the necessary information about the levels of most air pollutants; however, underdeveloped countries have inadequate information on air quality. The problem of poor air quality in many SSA countries is due to lack of information about the hazards of poor air quality, lack of monitoring equipment, and lack of measuring stations: this is the case in Cameroon. We are avoiding these problems by using portable, low-cost, low-maintenance air quality monitoring equipment, including the OC 300 dust particle laser, to observe pollution levels of particle matter levels in the PK17 Douala-Cameroon, a locality in the Central African region where no air quality data previously existed. The air quality index is very poor on the measurement days, and the color code is red. It has maximum values of about 199 for PM10 and 192 for PM2.5. The average concentration values obtained were of the order of 200.54 µg·m−3, 155.54 µg·m−3, 194.90 µg·m−3, and 194.03 µg·m−3 for PM10, respectively, on Tuesday, Thursday, Saturday, and Sunday. Regarding PM2.5, the average concentrations are 99.84 µg·m−3, 82.30 µg·m−3, 108.23 µg·m−3, and 112.97 µg·m−3, respectively, on Tuesday, Thursday, Saturday, and Sunday. A two-dimensional Gaussian model was used to estimate the particle matter concentration along each road. The nRMSE was 9% for PM10 and 12 for PM2.5, and the index-d for both particle sizes was close to 1 (0.74 for PM10 and 0.98 for PM2.5), which allows us to conclude that the calculated concentrations are the closest to the measured concentrations. The assessment reveals that most of the particulate matter during the measurement period was generated by road traffic. The concentration measured values of the pollutants are three times for PM2.5 and four times for PM10 above the recent WHO limits for daily exposure. In addition, it provides essential information on the pollution in Douala, which can be a major source of illness in the city and must be addressed.http://dx.doi.org/10.1155/2024/1787640
spellingShingle Yannick Cédric Ngangmo
Cyrille Adiang Mezoue
Cyrille Meukaleuni
Brice B. S. Wandjie
David Monkam
Assessment of Traffic-Related Ambient Air Particulate Matter (PM) Levels in Douala, Cameroon
Advances in Meteorology
title Assessment of Traffic-Related Ambient Air Particulate Matter (PM) Levels in Douala, Cameroon
title_full Assessment of Traffic-Related Ambient Air Particulate Matter (PM) Levels in Douala, Cameroon
title_fullStr Assessment of Traffic-Related Ambient Air Particulate Matter (PM) Levels in Douala, Cameroon
title_full_unstemmed Assessment of Traffic-Related Ambient Air Particulate Matter (PM) Levels in Douala, Cameroon
title_short Assessment of Traffic-Related Ambient Air Particulate Matter (PM) Levels in Douala, Cameroon
title_sort assessment of traffic related ambient air particulate matter pm levels in douala cameroon
url http://dx.doi.org/10.1155/2024/1787640
work_keys_str_mv AT yannickcedricngangmo assessmentoftrafficrelatedambientairparticulatematterpmlevelsindoualacameroon
AT cyrilleadiangmezoue assessmentoftrafficrelatedambientairparticulatematterpmlevelsindoualacameroon
AT cyrillemeukaleuni assessmentoftrafficrelatedambientairparticulatematterpmlevelsindoualacameroon
AT bricebswandjie assessmentoftrafficrelatedambientairparticulatematterpmlevelsindoualacameroon
AT davidmonkam assessmentoftrafficrelatedambientairparticulatematterpmlevelsindoualacameroon