Research and Evaluation for Passive Safety System in Low Pressure Reactor
Low pressure reactor is a small size advanced reactor with power of 180 MWt, which is under development at Nuclear Power Institute of China. In order to assess the ability and feasibility of passive safety system, several tests have been implemented on the passive safety system (PSS) test facility....
Saved in:
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Wiley
2015-01-01
|
Series: | Science and Technology of Nuclear Installations |
Online Access: | http://dx.doi.org/10.1155/2015/179235 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1832567973418631168 |
---|---|
author | Peng Chuanxin Zhuo Wenbin Chen Bingde Nie Changhua Huang Yanping |
author_facet | Peng Chuanxin Zhuo Wenbin Chen Bingde Nie Changhua Huang Yanping |
author_sort | Peng Chuanxin |
collection | DOAJ |
description | Low pressure reactor is a small size advanced reactor with power of 180 MWt, which is under development at Nuclear Power Institute of China. In order to assess the ability and feasibility of passive safety system, several tests have been implemented on the passive safety system (PSS) test facility. During the LOCA and SBO accident, the adequate core cooling is provided by the performance of passive safety system. In addition the best-estimate thermal hydraulic code, CATHARE V2.1, has been assessed against cold leg LOCA test. The calculation results show that CATHARE is in a satisfactory agreement with the test for the steady state and transient test. |
format | Article |
id | doaj-art-e66e998d57f449e7a53c5c1d7eca3286 |
institution | Kabale University |
issn | 1687-6075 1687-6083 |
language | English |
publishDate | 2015-01-01 |
publisher | Wiley |
record_format | Article |
series | Science and Technology of Nuclear Installations |
spelling | doaj-art-e66e998d57f449e7a53c5c1d7eca32862025-02-03T01:00:02ZengWileyScience and Technology of Nuclear Installations1687-60751687-60832015-01-01201510.1155/2015/179235179235Research and Evaluation for Passive Safety System in Low Pressure ReactorPeng Chuanxin0Zhuo Wenbin1Chen Bingde2Nie Changhua3Huang Yanping4Nuclear Power Institute of China, Chengdu 60041, ChinaNuclear Power Institute of China, Chengdu 60041, ChinaNuclear Power Institute of China, Chengdu 60041, ChinaNuclear Power Institute of China, Chengdu 60041, ChinaNuclear Power Institute of China, Chengdu 60041, ChinaLow pressure reactor is a small size advanced reactor with power of 180 MWt, which is under development at Nuclear Power Institute of China. In order to assess the ability and feasibility of passive safety system, several tests have been implemented on the passive safety system (PSS) test facility. During the LOCA and SBO accident, the adequate core cooling is provided by the performance of passive safety system. In addition the best-estimate thermal hydraulic code, CATHARE V2.1, has been assessed against cold leg LOCA test. The calculation results show that CATHARE is in a satisfactory agreement with the test for the steady state and transient test.http://dx.doi.org/10.1155/2015/179235 |
spellingShingle | Peng Chuanxin Zhuo Wenbin Chen Bingde Nie Changhua Huang Yanping Research and Evaluation for Passive Safety System in Low Pressure Reactor Science and Technology of Nuclear Installations |
title | Research and Evaluation for Passive Safety System in Low Pressure Reactor |
title_full | Research and Evaluation for Passive Safety System in Low Pressure Reactor |
title_fullStr | Research and Evaluation for Passive Safety System in Low Pressure Reactor |
title_full_unstemmed | Research and Evaluation for Passive Safety System in Low Pressure Reactor |
title_short | Research and Evaluation for Passive Safety System in Low Pressure Reactor |
title_sort | research and evaluation for passive safety system in low pressure reactor |
url | http://dx.doi.org/10.1155/2015/179235 |
work_keys_str_mv | AT pengchuanxin researchandevaluationforpassivesafetysysteminlowpressurereactor AT zhuowenbin researchandevaluationforpassivesafetysysteminlowpressurereactor AT chenbingde researchandevaluationforpassivesafetysysteminlowpressurereactor AT niechanghua researchandevaluationforpassivesafetysysteminlowpressurereactor AT huangyanping researchandevaluationforpassivesafetysysteminlowpressurereactor |