Deformation of Early Freezing Concrete in the Assessment Stress-Strain State of Reinforced Concrete Structures
When performing concreting works for structures in sub-zero temperatures, a situation often arises in which the technology of heating the concrete mix during its setting and hardening is violated. It is customary to specify in the project the minimum (critical) strength of concrete before its freezi...