Assessment of energy efficiency in use of downhole reactive power compensators

The article provides an assessment of the energy efficiency of the use of downhole compensators in the reactors as part of the installation of electric centrifugal pumps. A scheme for replacing the electrotechnical complex of an oil production facility has been developed. The energy efficiency c...

Full description

Saved in:
Bibliographic Details
Main Authors: V. A. Kopyrin, O. V. Smirnov, A. L. Portnyagin
Format: Article
Language:English
Published: Omsk State Technical University, Federal State Autonoumos Educational Institution of Higher Education 2018-04-01
Series:Омский научный вестник
Subjects:
Online Access:https://www.omgtu.ru/general_information/media_omgtu/journal_of_omsk_research_journal/files/arhiv/2018/2%20(158)/78-83%20%D0%9A%D0%BE%D0%BF%D1%8B%D1%80%D0%B8%D0%BD%20%D0%92.%20%D0%90.,%20%D0%A1%D0%BC%D0%B8%D1%80%D0%BD%D0%BE%D0%B2%20%D0%9E.%20%D0%92.,%20%D0%9F%D0%BE%D1%80%D1%82%D0%BD%D1%8F%D0%B3%D0%B8%D0%BD%20%D0%90.%20%D0%9B..pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832572976751443968
author V. A. Kopyrin
O. V. Smirnov
A. L. Portnyagin
author_facet V. A. Kopyrin
O. V. Smirnov
A. L. Portnyagin
author_sort V. A. Kopyrin
collection DOAJ
description The article provides an assessment of the energy efficiency of the use of downhole compensators in the reactors as part of the installation of electric centrifugal pumps. A scheme for replacing the electrotechnical complex of an oil production facility has been developed. The energy efficiency curves have been constructed characterizing the positive effect of the introduction of downhole compensators for different cross sections and lengths of supply cables.
format Article
id doaj-art-e598f3d8a7d24b6dabf293aaad7b6f5f
institution Kabale University
issn 1813-8225
2541-7541
language English
publishDate 2018-04-01
publisher Omsk State Technical University, Federal State Autonoumos Educational Institution of Higher Education
record_format Article
series Омский научный вестник
spelling doaj-art-e598f3d8a7d24b6dabf293aaad7b6f5f2025-02-02T05:58:20ZengOmsk State Technical University, Federal State Autonoumos Educational Institution of Higher EducationОмский научный вестник1813-82252541-75412018-04-012 (158)788310.25206/1813-8225-2018-158-78-83Assessment of energy efficiency in use of downhole reactive power compensatorsV. A. Kopyrin0O. V. Smirnov1A. L. Portnyagin2Industrial University of TyumenIndustrial University of TyumenIndustrial University of TyumenThe article provides an assessment of the energy efficiency of the use of downhole compensators in the reactors as part of the installation of electric centrifugal pumps. A scheme for replacing the electrotechnical complex of an oil production facility has been developed. The energy efficiency curves have been constructed characterizing the positive effect of the introduction of downhole compensators for different cross sections and lengths of supply cables.https://www.omgtu.ru/general_information/media_omgtu/journal_of_omsk_research_journal/files/arhiv/2018/2%20(158)/78-83%20%D0%9A%D0%BE%D0%BF%D1%8B%D1%80%D0%B8%D0%BD%20%D0%92.%20%D0%90.,%20%D0%A1%D0%BC%D0%B8%D1%80%D0%BD%D0%BE%D0%B2%20%D0%9E.%20%D0%92.,%20%D0%9F%D0%BE%D1%80%D1%82%D0%BD%D1%8F%D0%B3%D0%B8%D0%BD%20%D0%90.%20%D0%9B..pdfdownhole compensatorcable linesubmersible asynchronous motortransformerelectric centrifugal pump
spellingShingle V. A. Kopyrin
O. V. Smirnov
A. L. Portnyagin
Assessment of energy efficiency in use of downhole reactive power compensators
Омский научный вестник
downhole compensator
cable line
submersible asynchronous motor
transformer
electric centrifugal pump
title Assessment of energy efficiency in use of downhole reactive power compensators
title_full Assessment of energy efficiency in use of downhole reactive power compensators
title_fullStr Assessment of energy efficiency in use of downhole reactive power compensators
title_full_unstemmed Assessment of energy efficiency in use of downhole reactive power compensators
title_short Assessment of energy efficiency in use of downhole reactive power compensators
title_sort assessment of energy efficiency in use of downhole reactive power compensators
topic downhole compensator
cable line
submersible asynchronous motor
transformer
electric centrifugal pump
url https://www.omgtu.ru/general_information/media_omgtu/journal_of_omsk_research_journal/files/arhiv/2018/2%20(158)/78-83%20%D0%9A%D0%BE%D0%BF%D1%8B%D1%80%D0%B8%D0%BD%20%D0%92.%20%D0%90.,%20%D0%A1%D0%BC%D0%B8%D1%80%D0%BD%D0%BE%D0%B2%20%D0%9E.%20%D0%92.,%20%D0%9F%D0%BE%D1%80%D1%82%D0%BD%D1%8F%D0%B3%D0%B8%D0%BD%20%D0%90.%20%D0%9B..pdf
work_keys_str_mv AT vakopyrin assessmentofenergyefficiencyinuseofdownholereactivepowercompensators
AT ovsmirnov assessmentofenergyefficiencyinuseofdownholereactivepowercompensators
AT alportnyagin assessmentofenergyefficiencyinuseofdownholereactivepowercompensators