Assessment of energy efficiency in use of downhole reactive power compensators
The article provides an assessment of the energy efficiency of the use of downhole compensators in the reactors as part of the installation of electric centrifugal pumps. A scheme for replacing the electrotechnical complex of an oil production facility has been developed. The energy efficiency c...
Saved in:
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Omsk State Technical University, Federal State Autonoumos Educational Institution of Higher Education
2018-04-01
|
Series: | Омский научный вестник |
Subjects: | |
Online Access: | https://www.omgtu.ru/general_information/media_omgtu/journal_of_omsk_research_journal/files/arhiv/2018/2%20(158)/78-83%20%D0%9A%D0%BE%D0%BF%D1%8B%D1%80%D0%B8%D0%BD%20%D0%92.%20%D0%90.,%20%D0%A1%D0%BC%D0%B8%D1%80%D0%BD%D0%BE%D0%B2%20%D0%9E.%20%D0%92.,%20%D0%9F%D0%BE%D1%80%D1%82%D0%BD%D1%8F%D0%B3%D0%B8%D0%BD%20%D0%90.%20%D0%9B..pdf |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1832572976751443968 |
---|---|
author | V. A. Kopyrin O. V. Smirnov A. L. Portnyagin |
author_facet | V. A. Kopyrin O. V. Smirnov A. L. Portnyagin |
author_sort | V. A. Kopyrin |
collection | DOAJ |
description | The article provides an assessment of the energy efficiency of
the use of downhole compensators in the reactors as part of the
installation of electric centrifugal pumps. A scheme for replacing
the electrotechnical complex of an oil production facility has been
developed. The energy efficiency curves have been constructed
characterizing the positive effect of the introduction of downhole
compensators for different cross sections and lengths of supply
cables. |
format | Article |
id | doaj-art-e598f3d8a7d24b6dabf293aaad7b6f5f |
institution | Kabale University |
issn | 1813-8225 2541-7541 |
language | English |
publishDate | 2018-04-01 |
publisher | Omsk State Technical University, Federal State Autonoumos Educational Institution of Higher Education |
record_format | Article |
series | Омский научный вестник |
spelling | doaj-art-e598f3d8a7d24b6dabf293aaad7b6f5f2025-02-02T05:58:20ZengOmsk State Technical University, Federal State Autonoumos Educational Institution of Higher EducationОмский научный вестник1813-82252541-75412018-04-012 (158)788310.25206/1813-8225-2018-158-78-83Assessment of energy efficiency in use of downhole reactive power compensatorsV. A. Kopyrin0O. V. Smirnov1A. L. Portnyagin2Industrial University of TyumenIndustrial University of TyumenIndustrial University of TyumenThe article provides an assessment of the energy efficiency of the use of downhole compensators in the reactors as part of the installation of electric centrifugal pumps. A scheme for replacing the electrotechnical complex of an oil production facility has been developed. The energy efficiency curves have been constructed characterizing the positive effect of the introduction of downhole compensators for different cross sections and lengths of supply cables.https://www.omgtu.ru/general_information/media_omgtu/journal_of_omsk_research_journal/files/arhiv/2018/2%20(158)/78-83%20%D0%9A%D0%BE%D0%BF%D1%8B%D1%80%D0%B8%D0%BD%20%D0%92.%20%D0%90.,%20%D0%A1%D0%BC%D0%B8%D1%80%D0%BD%D0%BE%D0%B2%20%D0%9E.%20%D0%92.,%20%D0%9F%D0%BE%D1%80%D1%82%D0%BD%D1%8F%D0%B3%D0%B8%D0%BD%20%D0%90.%20%D0%9B..pdfdownhole compensatorcable linesubmersible asynchronous motortransformerelectric centrifugal pump |
spellingShingle | V. A. Kopyrin O. V. Smirnov A. L. Portnyagin Assessment of energy efficiency in use of downhole reactive power compensators Омский научный вестник downhole compensator cable line submersible asynchronous motor transformer electric centrifugal pump |
title | Assessment of energy efficiency in use of downhole reactive power compensators |
title_full | Assessment of energy efficiency in use of downhole reactive power compensators |
title_fullStr | Assessment of energy efficiency in use of downhole reactive power compensators |
title_full_unstemmed | Assessment of energy efficiency in use of downhole reactive power compensators |
title_short | Assessment of energy efficiency in use of downhole reactive power compensators |
title_sort | assessment of energy efficiency in use of downhole reactive power compensators |
topic | downhole compensator cable line submersible asynchronous motor transformer electric centrifugal pump |
url | https://www.omgtu.ru/general_information/media_omgtu/journal_of_omsk_research_journal/files/arhiv/2018/2%20(158)/78-83%20%D0%9A%D0%BE%D0%BF%D1%8B%D1%80%D0%B8%D0%BD%20%D0%92.%20%D0%90.,%20%D0%A1%D0%BC%D0%B8%D1%80%D0%BD%D0%BE%D0%B2%20%D0%9E.%20%D0%92.,%20%D0%9F%D0%BE%D1%80%D1%82%D0%BD%D1%8F%D0%B3%D0%B8%D0%BD%20%D0%90.%20%D0%9B..pdf |
work_keys_str_mv | AT vakopyrin assessmentofenergyefficiencyinuseofdownholereactivepowercompensators AT ovsmirnov assessmentofenergyefficiencyinuseofdownholereactivepowercompensators AT alportnyagin assessmentofenergyefficiencyinuseofdownholereactivepowercompensators |