USE OF ISOTOPE DILUTION METHOD FOR DETERMINATION OF Ce, Sm, AND Yb ABUNDANCES IN GEOLOGICAL SAMPLES BY ICP-MS
In this study, we used the ID-ICP-MS technique to determine the concentration of Ce (LREE), Sm (MREE), and Yb (HREE) in three geological, certified reference materials: BHVO-2, BCR-2, and NIST 2711a. Calibration experiments using the ID technique, such as concentration calibration and relative isoto...
Saved in:
Main Authors: | , , , , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Dalat University
2019-08-01
|
Series: | Tạp chí Khoa học Đại học Đà Lạt |
Subjects: | |
Online Access: | http://tckh.dlu.edu.vn/index.php/tckhdhdl/article/view/517 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1832569901568491520 |
---|---|
author | Cao Đông Vũ Trương Đức Toàn Nguyễn Đăng Khánh Đỗ Tâm Nhân Võ Trần Quang Thái Nguyễn Lê Anh Nguyễn Việt Đức Nguyễn Giằng Nguyễn Trọng Ngọ |
author_facet | Cao Đông Vũ Trương Đức Toàn Nguyễn Đăng Khánh Đỗ Tâm Nhân Võ Trần Quang Thái Nguyễn Lê Anh Nguyễn Việt Đức Nguyễn Giằng Nguyễn Trọng Ngọ |
author_sort | Cao Đông Vũ |
collection | DOAJ |
description | In this study, we used the ID-ICP-MS technique to determine the concentration of Ce (LREE), Sm (MREE), and Yb (HREE) in three geological, certified reference materials: BHVO-2, BCR-2, and NIST 2711a. Calibration experiments using the ID technique, such as concentration calibration and relative isotopic abundance calibration for spike solutions, were conducted experimentally. In addition, mass spectral interferences and mass fractionation in ICP-MS were also investigated, corrected and discussed. For the first time in Vietnam, ID-ICP-MS has been successfully applied to determine three rare earth elements Ce, Sm, and Yb in basaltic geological samples (BHVO-2 and BCR-2) with high accuracy and reproducibility (<5%). For NIST SRM 2711a with soil matrix, the results of the accuracy and reproducibility were approximately 10%, except for the result obtained for Ce, with a dilution factor of 3000, which was 15.4% lower than the published value. |
format | Article |
id | doaj-art-e46e327f0e664206a51f15518a64b67f |
institution | Kabale University |
issn | 0866-787X 0866-787X |
language | English |
publishDate | 2019-08-01 |
publisher | Dalat University |
record_format | Article |
series | Tạp chí Khoa học Đại học Đà Lạt |
spelling | doaj-art-e46e327f0e664206a51f15518a64b67f2025-02-02T19:05:21ZengDalat UniversityTạp chí Khoa học Đại học Đà Lạt0866-787X0866-787X2019-08-0192496910.37569/DalatUniversity.9.2.517(2019)283USE OF ISOTOPE DILUTION METHOD FOR DETERMINATION OF Ce, Sm, AND Yb ABUNDANCES IN GEOLOGICAL SAMPLES BY ICP-MSCao Đông Vũ0Trương Đức Toàn1Nguyễn Đăng Khánh2Đỗ Tâm Nhân3Võ Trần Quang Thái4Nguyễn Lê Anh5Nguyễn Việt Đức6Nguyễn Giằng7Nguyễn Trọng Ngọ8Viện Nghiên cứu Hạt nhân, Viện Năng lượng Nguyên tử Việt NamViện Nghiên cứu Hạt nhân, Viện Năng lượng Nguyên tử Việt NamPhòng Đào tạo Sau đại học, Trường Đại học Đà LạtViện Nghiên cứu Hạt nhân, Viện Năng lượng Nguyên tử Việt NamViện Nghiên cứu Hạt nhân, Viện Năng lượng Nguyên tử Việt NamViện Nghiên cứu Hạt nhân, Viện Năng lượng Nguyên tử Việt NamViện Nghiên cứu Hạt nhân, Viện Năng lượng Nguyên tử Việt NamViện Nghiên cứu Hạt nhân, Viện Năng lượng Nguyên tử Việt NamViện Nghiên cứu Hạt nhân, Viện Năng lượng Nguyên tử Việt NamIn this study, we used the ID-ICP-MS technique to determine the concentration of Ce (LREE), Sm (MREE), and Yb (HREE) in three geological, certified reference materials: BHVO-2, BCR-2, and NIST 2711a. Calibration experiments using the ID technique, such as concentration calibration and relative isotopic abundance calibration for spike solutions, were conducted experimentally. In addition, mass spectral interferences and mass fractionation in ICP-MS were also investigated, corrected and discussed. For the first time in Vietnam, ID-ICP-MS has been successfully applied to determine three rare earth elements Ce, Sm, and Yb in basaltic geological samples (BHVO-2 and BCR-2) with high accuracy and reproducibility (<5%). For NIST SRM 2711a with soil matrix, the results of the accuracy and reproducibility were approximately 10%, except for the result obtained for Ce, with a dilution factor of 3000, which was 15.4% lower than the published value.http://tckh.dlu.edu.vn/index.php/tckhdhdl/article/view/517các nguyên tố đất hiếm (rees)icp-mspha loãng đồng vị (id). |
spellingShingle | Cao Đông Vũ Trương Đức Toàn Nguyễn Đăng Khánh Đỗ Tâm Nhân Võ Trần Quang Thái Nguyễn Lê Anh Nguyễn Việt Đức Nguyễn Giằng Nguyễn Trọng Ngọ USE OF ISOTOPE DILUTION METHOD FOR DETERMINATION OF Ce, Sm, AND Yb ABUNDANCES IN GEOLOGICAL SAMPLES BY ICP-MS Tạp chí Khoa học Đại học Đà Lạt các nguyên tố đất hiếm (rees) icp-ms pha loãng đồng vị (id). |
title | USE OF ISOTOPE DILUTION METHOD FOR DETERMINATION OF Ce, Sm, AND Yb ABUNDANCES IN GEOLOGICAL SAMPLES BY ICP-MS |
title_full | USE OF ISOTOPE DILUTION METHOD FOR DETERMINATION OF Ce, Sm, AND Yb ABUNDANCES IN GEOLOGICAL SAMPLES BY ICP-MS |
title_fullStr | USE OF ISOTOPE DILUTION METHOD FOR DETERMINATION OF Ce, Sm, AND Yb ABUNDANCES IN GEOLOGICAL SAMPLES BY ICP-MS |
title_full_unstemmed | USE OF ISOTOPE DILUTION METHOD FOR DETERMINATION OF Ce, Sm, AND Yb ABUNDANCES IN GEOLOGICAL SAMPLES BY ICP-MS |
title_short | USE OF ISOTOPE DILUTION METHOD FOR DETERMINATION OF Ce, Sm, AND Yb ABUNDANCES IN GEOLOGICAL SAMPLES BY ICP-MS |
title_sort | use of isotope dilution method for determination of ce sm and yb abundances in geological samples by icp ms |
topic | các nguyên tố đất hiếm (rees) icp-ms pha loãng đồng vị (id). |
url | http://tckh.dlu.edu.vn/index.php/tckhdhdl/article/view/517 |
work_keys_str_mv | AT caođongvu useofisotopedilutionmethodfordeterminationofcesmandybabundancesingeologicalsamplesbyicpms AT truongđuctoan useofisotopedilutionmethodfordeterminationofcesmandybabundancesingeologicalsamplesbyicpms AT nguyenđangkhanh useofisotopedilutionmethodfordeterminationofcesmandybabundancesingeologicalsamplesbyicpms AT đotamnhan useofisotopedilutionmethodfordeterminationofcesmandybabundancesingeologicalsamplesbyicpms AT votranquangthai useofisotopedilutionmethodfordeterminationofcesmandybabundancesingeologicalsamplesbyicpms AT nguyenleanh useofisotopedilutionmethodfordeterminationofcesmandybabundancesingeologicalsamplesbyicpms AT nguyenvietđuc useofisotopedilutionmethodfordeterminationofcesmandybabundancesingeologicalsamplesbyicpms AT nguyengiang useofisotopedilutionmethodfordeterminationofcesmandybabundancesingeologicalsamplesbyicpms AT nguyentrongngo useofisotopedilutionmethodfordeterminationofcesmandybabundancesingeologicalsamplesbyicpms |