USE OF ISOTOPE DILUTION METHOD FOR DETERMINATION OF Ce, Sm, AND Yb ABUNDANCES IN GEOLOGICAL SAMPLES BY ICP-MS

In this study, we used the ID-ICP-MS technique to determine the concentration of Ce (LREE), Sm (MREE), and Yb (HREE) in three geological, certified reference materials: BHVO-2, BCR-2, and NIST 2711a. Calibration experiments using the ID technique, such as concentration calibration and relative isoto...

Full description

Saved in:
Bibliographic Details
Main Authors: Cao Đông Vũ, Trương Đức Toàn, Nguyễn Đăng Khánh, Đỗ Tâm Nhân, Võ Trần Quang Thái, Nguyễn Lê Anh, Nguyễn Việt Đức, Nguyễn Giằng, Nguyễn Trọng Ngọ
Format: Article
Language:English
Published: Dalat University 2019-08-01
Series:Tạp chí Khoa học Đại học Đà Lạt
Subjects:
Online Access:http://tckh.dlu.edu.vn/index.php/tckhdhdl/article/view/517
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832569901568491520
author Cao Đông Vũ
Trương Đức Toàn
Nguyễn Đăng Khánh
Đỗ Tâm Nhân
Võ Trần Quang Thái
Nguyễn Lê Anh
Nguyễn Việt Đức
Nguyễn Giằng
Nguyễn Trọng Ngọ
author_facet Cao Đông Vũ
Trương Đức Toàn
Nguyễn Đăng Khánh
Đỗ Tâm Nhân
Võ Trần Quang Thái
Nguyễn Lê Anh
Nguyễn Việt Đức
Nguyễn Giằng
Nguyễn Trọng Ngọ
author_sort Cao Đông Vũ
collection DOAJ
description In this study, we used the ID-ICP-MS technique to determine the concentration of Ce (LREE), Sm (MREE), and Yb (HREE) in three geological, certified reference materials: BHVO-2, BCR-2, and NIST 2711a. Calibration experiments using the ID technique, such as concentration calibration and relative isotopic abundance calibration for spike solutions, were conducted experimentally. In addition, mass spectral interferences and mass fractionation in ICP-MS were also investigated, corrected and discussed. For the first time in Vietnam, ID-ICP-MS has been successfully applied to determine three rare earth elements Ce, Sm, and Yb in basaltic geological samples (BHVO-2 and BCR-2) with high accuracy and reproducibility (<5%). For NIST SRM 2711a with soil matrix, the results of the accuracy and reproducibility were approximately 10%, except for the result obtained for Ce, with a dilution factor of 3000, which was 15.4% lower than the published value.
format Article
id doaj-art-e46e327f0e664206a51f15518a64b67f
institution Kabale University
issn 0866-787X
0866-787X
language English
publishDate 2019-08-01
publisher Dalat University
record_format Article
series Tạp chí Khoa học Đại học Đà Lạt
spelling doaj-art-e46e327f0e664206a51f15518a64b67f2025-02-02T19:05:21ZengDalat UniversityTạp chí Khoa học Đại học Đà Lạt0866-787X0866-787X2019-08-0192496910.37569/DalatUniversity.9.2.517(2019)283USE OF ISOTOPE DILUTION METHOD FOR DETERMINATION OF Ce, Sm, AND Yb ABUNDANCES IN GEOLOGICAL SAMPLES BY ICP-MSCao Đông Vũ0Trương Đức Toàn1Nguyễn Đăng Khánh2Đỗ Tâm Nhân3Võ Trần Quang Thái4Nguyễn Lê Anh5Nguyễn Việt Đức6Nguyễn Giằng7Nguyễn Trọng Ngọ8Viện Nghiên cứu Hạt nhân, Viện Năng lượng Nguyên tử Việt NamViện Nghiên cứu Hạt nhân, Viện Năng lượng Nguyên tử Việt NamPhòng Đào tạo Sau đại học, Trường Đại học Đà LạtViện Nghiên cứu Hạt nhân, Viện Năng lượng Nguyên tử Việt NamViện Nghiên cứu Hạt nhân, Viện Năng lượng Nguyên tử Việt NamViện Nghiên cứu Hạt nhân, Viện Năng lượng Nguyên tử Việt NamViện Nghiên cứu Hạt nhân, Viện Năng lượng Nguyên tử Việt NamViện Nghiên cứu Hạt nhân, Viện Năng lượng Nguyên tử Việt NamViện Nghiên cứu Hạt nhân, Viện Năng lượng Nguyên tử Việt NamIn this study, we used the ID-ICP-MS technique to determine the concentration of Ce (LREE), Sm (MREE), and Yb (HREE) in three geological, certified reference materials: BHVO-2, BCR-2, and NIST 2711a. Calibration experiments using the ID technique, such as concentration calibration and relative isotopic abundance calibration for spike solutions, were conducted experimentally. In addition, mass spectral interferences and mass fractionation in ICP-MS were also investigated, corrected and discussed. For the first time in Vietnam, ID-ICP-MS has been successfully applied to determine three rare earth elements Ce, Sm, and Yb in basaltic geological samples (BHVO-2 and BCR-2) with high accuracy and reproducibility (<5%). For NIST SRM 2711a with soil matrix, the results of the accuracy and reproducibility were approximately 10%, except for the result obtained for Ce, with a dilution factor of 3000, which was 15.4% lower than the published value.http://tckh.dlu.edu.vn/index.php/tckhdhdl/article/view/517các nguyên tố đất hiếm (rees)icp-mspha loãng đồng vị (id).
spellingShingle Cao Đông Vũ
Trương Đức Toàn
Nguyễn Đăng Khánh
Đỗ Tâm Nhân
Võ Trần Quang Thái
Nguyễn Lê Anh
Nguyễn Việt Đức
Nguyễn Giằng
Nguyễn Trọng Ngọ
USE OF ISOTOPE DILUTION METHOD FOR DETERMINATION OF Ce, Sm, AND Yb ABUNDANCES IN GEOLOGICAL SAMPLES BY ICP-MS
Tạp chí Khoa học Đại học Đà Lạt
các nguyên tố đất hiếm (rees)
icp-ms
pha loãng đồng vị (id).
title USE OF ISOTOPE DILUTION METHOD FOR DETERMINATION OF Ce, Sm, AND Yb ABUNDANCES IN GEOLOGICAL SAMPLES BY ICP-MS
title_full USE OF ISOTOPE DILUTION METHOD FOR DETERMINATION OF Ce, Sm, AND Yb ABUNDANCES IN GEOLOGICAL SAMPLES BY ICP-MS
title_fullStr USE OF ISOTOPE DILUTION METHOD FOR DETERMINATION OF Ce, Sm, AND Yb ABUNDANCES IN GEOLOGICAL SAMPLES BY ICP-MS
title_full_unstemmed USE OF ISOTOPE DILUTION METHOD FOR DETERMINATION OF Ce, Sm, AND Yb ABUNDANCES IN GEOLOGICAL SAMPLES BY ICP-MS
title_short USE OF ISOTOPE DILUTION METHOD FOR DETERMINATION OF Ce, Sm, AND Yb ABUNDANCES IN GEOLOGICAL SAMPLES BY ICP-MS
title_sort use of isotope dilution method for determination of ce sm and yb abundances in geological samples by icp ms
topic các nguyên tố đất hiếm (rees)
icp-ms
pha loãng đồng vị (id).
url http://tckh.dlu.edu.vn/index.php/tckhdhdl/article/view/517
work_keys_str_mv AT caođongvu useofisotopedilutionmethodfordeterminationofcesmandybabundancesingeologicalsamplesbyicpms
AT truongđuctoan useofisotopedilutionmethodfordeterminationofcesmandybabundancesingeologicalsamplesbyicpms
AT nguyenđangkhanh useofisotopedilutionmethodfordeterminationofcesmandybabundancesingeologicalsamplesbyicpms
AT đotamnhan useofisotopedilutionmethodfordeterminationofcesmandybabundancesingeologicalsamplesbyicpms
AT votranquangthai useofisotopedilutionmethodfordeterminationofcesmandybabundancesingeologicalsamplesbyicpms
AT nguyenleanh useofisotopedilutionmethodfordeterminationofcesmandybabundancesingeologicalsamplesbyicpms
AT nguyenvietđuc useofisotopedilutionmethodfordeterminationofcesmandybabundancesingeologicalsamplesbyicpms
AT nguyengiang useofisotopedilutionmethodfordeterminationofcesmandybabundancesingeologicalsamplesbyicpms
AT nguyentrongngo useofisotopedilutionmethodfordeterminationofcesmandybabundancesingeologicalsamplesbyicpms