Case Studies on Enhanced Heat Transfer in a Square Duct with Modified V-Shaped Ribs (MVR): A CFD Analysis

This research presents structural improvement of V-shaped ribs for a tested square duct (TSD). The V-shaped ribs, which are inserted at the middle of the TSD (called type A), and the V-shaped ribs, which are placed on the opposite TSD walls (called type B), are modified to increase the structural st...

Full description

Saved in:
Bibliographic Details
Main Authors: Amnart Boonloi, Withada Jedsadaratanachai
Format: Article
Language:English
Published: Wiley 2022-01-01
Series:Modelling and Simulation in Engineering
Online Access:http://dx.doi.org/10.1155/2022/5376486
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832560908645171200
author Amnart Boonloi
Withada Jedsadaratanachai
author_facet Amnart Boonloi
Withada Jedsadaratanachai
author_sort Amnart Boonloi
collection DOAJ
description This research presents structural improvement of V-shaped ribs for a tested square duct (TSD). The V-shaped ribs, which are inserted at the middle of the TSD (called type A), and the V-shaped ribs, which are placed on the opposite TSD walls (called type B), are modified to increase the structural stabilization. The effects of rib height to duct height, b/H=0.05–0.30; V-shaped bar thickness to duct height, a/H=0.025 and 0.050; and flow directions (V-Upstream and V-Downstream) are considered. The new design of the V-shaped ribs is called “modified V-shaped ribs or MVR.” The present problem is solved by the numerical method (commercial code). The flow and heat transfer features of the TSD are illustrated. The numerical result reveals that the MVR give both flow and heat transfer patterns similarly as the general V-shaped rib. The impinging flows, swirling flows, and disturbing thermal boundary layer, which lead to enhanced heat transfer, are observed. Over the investigated range, the enhanced heat transfer about 18.12 times above the smooth duct with the optimal thermal enhancement factor about 4.16 is detected.
format Article
id doaj-art-e3c2f37381e94daebb21c9ea803c6b48
institution Kabale University
issn 1687-5605
language English
publishDate 2022-01-01
publisher Wiley
record_format Article
series Modelling and Simulation in Engineering
spelling doaj-art-e3c2f37381e94daebb21c9ea803c6b482025-02-03T01:26:34ZengWileyModelling and Simulation in Engineering1687-56052022-01-01202210.1155/2022/5376486Case Studies on Enhanced Heat Transfer in a Square Duct with Modified V-Shaped Ribs (MVR): A CFD AnalysisAmnart Boonloi0Withada Jedsadaratanachai1Department of Mechanical Engineering TechnologyDepartment of Mechanical EngineeringThis research presents structural improvement of V-shaped ribs for a tested square duct (TSD). The V-shaped ribs, which are inserted at the middle of the TSD (called type A), and the V-shaped ribs, which are placed on the opposite TSD walls (called type B), are modified to increase the structural stabilization. The effects of rib height to duct height, b/H=0.05–0.30; V-shaped bar thickness to duct height, a/H=0.025 and 0.050; and flow directions (V-Upstream and V-Downstream) are considered. The new design of the V-shaped ribs is called “modified V-shaped ribs or MVR.” The present problem is solved by the numerical method (commercial code). The flow and heat transfer features of the TSD are illustrated. The numerical result reveals that the MVR give both flow and heat transfer patterns similarly as the general V-shaped rib. The impinging flows, swirling flows, and disturbing thermal boundary layer, which lead to enhanced heat transfer, are observed. Over the investigated range, the enhanced heat transfer about 18.12 times above the smooth duct with the optimal thermal enhancement factor about 4.16 is detected.http://dx.doi.org/10.1155/2022/5376486
spellingShingle Amnart Boonloi
Withada Jedsadaratanachai
Case Studies on Enhanced Heat Transfer in a Square Duct with Modified V-Shaped Ribs (MVR): A CFD Analysis
Modelling and Simulation in Engineering
title Case Studies on Enhanced Heat Transfer in a Square Duct with Modified V-Shaped Ribs (MVR): A CFD Analysis
title_full Case Studies on Enhanced Heat Transfer in a Square Duct with Modified V-Shaped Ribs (MVR): A CFD Analysis
title_fullStr Case Studies on Enhanced Heat Transfer in a Square Duct with Modified V-Shaped Ribs (MVR): A CFD Analysis
title_full_unstemmed Case Studies on Enhanced Heat Transfer in a Square Duct with Modified V-Shaped Ribs (MVR): A CFD Analysis
title_short Case Studies on Enhanced Heat Transfer in a Square Duct with Modified V-Shaped Ribs (MVR): A CFD Analysis
title_sort case studies on enhanced heat transfer in a square duct with modified v shaped ribs mvr a cfd analysis
url http://dx.doi.org/10.1155/2022/5376486
work_keys_str_mv AT amnartboonloi casestudiesonenhancedheattransferinasquareductwithmodifiedvshapedribsmvracfdanalysis
AT withadajedsadaratanachai casestudiesonenhancedheattransferinasquareductwithmodifiedvshapedribsmvracfdanalysis