Improvement of Transformer Relay Protection Sensitivity with Wide Range of Voltage Control
The paper shows that it is possible to increase a design sensitivity coefficient of the transformer relay protection with voltage switch ∆UРПН= ±16% due to application of more precise method for calculation of minimum and maximum short circuit currents beyond a transformer with intermediate branc...
Saved in:
Main Author: | |
---|---|
Format: | Article |
Language: | Russian |
Published: |
Belarusian National Technical University
2009-10-01
|
Series: | Известия высших учебных заведений и энергетических объединенний СНГ: Энергетика |
Online Access: | https://energy.bntu.by/jour/article/view/470 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1832543743536791552 |
---|---|
author | V. V. Kourganov |
author_facet | V. V. Kourganov |
author_sort | V. V. Kourganov |
collection | DOAJ |
description | The paper shows that it is possible to increase a design sensitivity coefficient of the transformer relay protection with voltage switch ∆UРПН= ±16% due to application of more precise method for calculation of minimum and maximum short circuit currents beyond a transformer with intermediate branches of a load control switch that correspond to an actual voltage variation range in 110 kV networks. |
format | Article |
id | doaj-art-e3504b6a84db461dafec38eb227ea123 |
institution | Kabale University |
issn | 1029-7448 2414-0341 |
language | Russian |
publishDate | 2009-10-01 |
publisher | Belarusian National Technical University |
record_format | Article |
series | Известия высших учебных заведений и энергетических объединенний СНГ: Энергетика |
spelling | doaj-art-e3504b6a84db461dafec38eb227ea1232025-02-03T11:34:24ZrusBelarusian National Technical UniversityИзвестия высших учебных заведений и энергетических объединенний СНГ: Энергетика1029-74482414-03412009-10-0105364210.21122/1029-7448-2009-0-5-28-34463Improvement of Transformer Relay Protection Sensitivity with Wide Range of Voltage ControlV. V. KourganovThe paper shows that it is possible to increase a design sensitivity coefficient of the transformer relay protection with voltage switch ∆UРПН= ±16% due to application of more precise method for calculation of minimum and maximum short circuit currents beyond a transformer with intermediate branches of a load control switch that correspond to an actual voltage variation range in 110 kV networks.https://energy.bntu.by/jour/article/view/470 |
spellingShingle | V. V. Kourganov Improvement of Transformer Relay Protection Sensitivity with Wide Range of Voltage Control Известия высших учебных заведений и энергетических объединенний СНГ: Энергетика |
title | Improvement of Transformer Relay Protection Sensitivity with Wide Range of Voltage Control |
title_full | Improvement of Transformer Relay Protection Sensitivity with Wide Range of Voltage Control |
title_fullStr | Improvement of Transformer Relay Protection Sensitivity with Wide Range of Voltage Control |
title_full_unstemmed | Improvement of Transformer Relay Protection Sensitivity with Wide Range of Voltage Control |
title_short | Improvement of Transformer Relay Protection Sensitivity with Wide Range of Voltage Control |
title_sort | improvement of transformer relay protection sensitivity with wide range of voltage control |
url | https://energy.bntu.by/jour/article/view/470 |
work_keys_str_mv | AT vvkourganov improvementoftransformerrelayprotectionsensitivitywithwiderangeofvoltagecontrol |