State of intracardiac and central hemodynamics in patients with mitral valve insufficiency during surgery with cardioprotection by electrical fibrillation and intermittent aortic clamping

The aim – to evaluate the state of intracardiac and central hemodynamics in patients with mitral valve insufficiency during surgery with cardioprotection by electrical fibrillation and intermittent aortic clamping. Materials and methods. We examined 45 patients with mitral valve insufficiency admit...

Full description

Saved in:
Bibliographic Details
Main Authors: B.M. Todurov, Yu.A. Kharenko, M.V. Khartanovich, V.B. Demyanchuk, I.Yu. Mokryk
Format: Article
Language:English
Published: TOV Chetverta Khvylia 2019-12-01
Series:Кардіохірургія та інтервенційна кардіологія
Subjects:
Online Access:http://csic.com.ua/images/pdf/2019/4-2019/state-of-intracardiac-and-central-hemodynamics-in-patients-with-mitral-valve-insufficiency.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832568742656081920
author B.M. Todurov
Yu.A. Kharenko
M.V. Khartanovich
V.B. Demyanchuk
I.Yu. Mokryk
author_facet B.M. Todurov
Yu.A. Kharenko
M.V. Khartanovich
V.B. Demyanchuk
I.Yu. Mokryk
author_sort B.M. Todurov
collection DOAJ
description The aim – to evaluate the state of intracardiac and central hemodynamics in patients with mitral valve insufficiency during surgery with cardioprotection by electrical fibrillation and intermittent aortic clamping. Materials and methods. We examined 45 patients with mitral valve insufficiency admitted for surgery of the defect. All patients underwent mitral valve replacement, and the local protocol оf the protection of myocardium was performed by applying electrical cardiac fibrillation and intermittent clamping of the aorta. Left ventricular end systolic, end diastolic and stroke index, ejection fraction, as well as cardiac index, pulmonary artery systolic pressure and global longitudinal myocardial strain were determined at the end of the сardiopulmonary bypass, before being transferred to intensive care unit (ICU) and after leaving ICU. Results. The end systolic index was not significantly altered during the study stages. At the same time, end systolic index gradually decreased and, before being transferred from ICU, became significantly lower than the baseline (p < 0.03), although such dynamics did not affect the stroke index. The ejection fraction at the end of сardiopulmonary bypass insignificantly increased to 53.6 ± 4.1 % and then remained almost at the same level: 53.2 ± 5.4 % before being transferred to the ICU and 54.2 ± 6.2 % before transfer from ICU. The global longitudinal myocardial strain module at the end of the сardiopulmonary bypass significantly (p < 0.003) decreased to –11.9 ± 0.8 %, then gradually returned to the previous level. PPAs after correction of the defect and at the end of сardiopulmonary bypass significantly decreased to 36.8 ± 2.6 mm Hg (p < 0.0001), further, before transferring to the ICU, it became still significantly (p < 0.004) lower. All cardiac index changes during the study were insignificant. Conclusions. These results indicate that the cardioprotection method used did not have a negative impact on myocardial contractility, central and intracardiac hemodynamic parameters.
format Article
id doaj-art-e34d8478b7b94668bd3e9e0b329b07ba
institution Kabale University
issn 2305-3127
language English
publishDate 2019-12-01
publisher TOV Chetverta Khvylia
record_format Article
series Кардіохірургія та інтервенційна кардіологія
spelling doaj-art-e34d8478b7b94668bd3e9e0b329b07ba2025-02-03T00:38:13ZengTOV Chetverta KhvyliaКардіохірургія та інтервенційна кардіологія2305-31272019-12-014152010.31928/2305-3127-2019.4.1520State of intracardiac and central hemodynamics in patients with mitral valve insufficiency during surgery with cardioprotection by electrical fibrillation and intermittent aortic clampingB.M. Todurov0Yu.A. Kharenko1M.V. Khartanovich2V.B. Demyanchuk3 I.Yu. Mokryk4Heart Institute, Ministry of Health of Ukraine, Kyiv, Ukraine; Shupyk National Medical Academy of Postgraduate Education, Kyiv, UkraineHeart Institute, Ministry of Health of Ukraine, Kyiv, Ukraine; Shupyk National Medical Academy of Postgraduate Education, Kyiv, UkraineHeart Institute, Ministry of Health of Ukraine, Kyiv, UkraineHeart Institute, Ministry of Health of Ukraine, Kyiv, Ukraine; Shupyk National Medical Academy of Postgraduate Education, Kyiv, UkraineHeart Institute, Ministry of Health of Ukraine, Kyiv, UkraineThe aim – to evaluate the state of intracardiac and central hemodynamics in patients with mitral valve insufficiency during surgery with cardioprotection by electrical fibrillation and intermittent aortic clamping. Materials and methods. We examined 45 patients with mitral valve insufficiency admitted for surgery of the defect. All patients underwent mitral valve replacement, and the local protocol оf the protection of myocardium was performed by applying electrical cardiac fibrillation and intermittent clamping of the aorta. Left ventricular end systolic, end diastolic and stroke index, ejection fraction, as well as cardiac index, pulmonary artery systolic pressure and global longitudinal myocardial strain were determined at the end of the сardiopulmonary bypass, before being transferred to intensive care unit (ICU) and after leaving ICU. Results. The end systolic index was not significantly altered during the study stages. At the same time, end systolic index gradually decreased and, before being transferred from ICU, became significantly lower than the baseline (p < 0.03), although such dynamics did not affect the stroke index. The ejection fraction at the end of сardiopulmonary bypass insignificantly increased to 53.6 ± 4.1 % and then remained almost at the same level: 53.2 ± 5.4 % before being transferred to the ICU and 54.2 ± 6.2 % before transfer from ICU. The global longitudinal myocardial strain module at the end of the сardiopulmonary bypass significantly (p < 0.003) decreased to –11.9 ± 0.8 %, then gradually returned to the previous level. PPAs after correction of the defect and at the end of сardiopulmonary bypass significantly decreased to 36.8 ± 2.6 mm Hg (p < 0.0001), further, before transferring to the ICU, it became still significantly (p < 0.004) lower. All cardiac index changes during the study were insignificant. Conclusions. These results indicate that the cardioprotection method used did not have a negative impact on myocardial contractility, central and intracardiac hemodynamic parameters.http://csic.com.ua/images/pdf/2019/4-2019/state-of-intracardiac-and-central-hemodynamics-in-patients-with-mitral-valve-insufficiency.pdfintracardiac hemodynamicscentral hemodynamicsmitral valve insufficiencycardioprotectionelectrical fibrillationintermittent aortic clamping
spellingShingle B.M. Todurov
Yu.A. Kharenko
M.V. Khartanovich
V.B. Demyanchuk
I.Yu. Mokryk
State of intracardiac and central hemodynamics in patients with mitral valve insufficiency during surgery with cardioprotection by electrical fibrillation and intermittent aortic clamping
Кардіохірургія та інтервенційна кардіологія
intracardiac hemodynamics
central hemodynamics
mitral valve insufficiency
cardioprotection
electrical fibrillation
intermittent aortic clamping
title State of intracardiac and central hemodynamics in patients with mitral valve insufficiency during surgery with cardioprotection by electrical fibrillation and intermittent aortic clamping
title_full State of intracardiac and central hemodynamics in patients with mitral valve insufficiency during surgery with cardioprotection by electrical fibrillation and intermittent aortic clamping
title_fullStr State of intracardiac and central hemodynamics in patients with mitral valve insufficiency during surgery with cardioprotection by electrical fibrillation and intermittent aortic clamping
title_full_unstemmed State of intracardiac and central hemodynamics in patients with mitral valve insufficiency during surgery with cardioprotection by electrical fibrillation and intermittent aortic clamping
title_short State of intracardiac and central hemodynamics in patients with mitral valve insufficiency during surgery with cardioprotection by electrical fibrillation and intermittent aortic clamping
title_sort state of intracardiac and central hemodynamics in patients with mitral valve insufficiency during surgery with cardioprotection by electrical fibrillation and intermittent aortic clamping
topic intracardiac hemodynamics
central hemodynamics
mitral valve insufficiency
cardioprotection
electrical fibrillation
intermittent aortic clamping
url http://csic.com.ua/images/pdf/2019/4-2019/state-of-intracardiac-and-central-hemodynamics-in-patients-with-mitral-valve-insufficiency.pdf
work_keys_str_mv AT bmtodurov stateofintracardiacandcentralhemodynamicsinpatientswithmitralvalveinsufficiencyduringsurgerywithcardioprotectionbyelectricalfibrillationandintermittentaorticclamping
AT yuakharenko stateofintracardiacandcentralhemodynamicsinpatientswithmitralvalveinsufficiencyduringsurgerywithcardioprotectionbyelectricalfibrillationandintermittentaorticclamping
AT mvkhartanovich stateofintracardiacandcentralhemodynamicsinpatientswithmitralvalveinsufficiencyduringsurgerywithcardioprotectionbyelectricalfibrillationandintermittentaorticclamping
AT vbdemyanchuk stateofintracardiacandcentralhemodynamicsinpatientswithmitralvalveinsufficiencyduringsurgerywithcardioprotectionbyelectricalfibrillationandintermittentaorticclamping
AT iyumokryk stateofintracardiacandcentralhemodynamicsinpatientswithmitralvalveinsufficiencyduringsurgerywithcardioprotectionbyelectricalfibrillationandintermittentaorticclamping