THE ANALYSIS OF STRUCTURAL RELIABILITY OF THE MAIN ELECTRIC CONNECTION CIRCUITS OF NUCLEAR POWER PLANTS

The reliability of the main circuit of electrical connections at a nuclear electric power plant that has two units with a capacity of 1,200 MW each has been determined. Reliability, economical, maneuverable properties of the atomic power plant under study are largely determined by its main circuit,...

Full description

Saved in:
Bibliographic Details
Main Authors: M. A. Korotkevich, A. L. Starzhinskij
Format: Article
Language:Russian
Published: Belarusian National Technical University 2017-05-01
Series:Известия высших учебных заведений и энергетических объединенний СНГ: Энергетика
Subjects:
Online Access:https://energy.bntu.by/jour/article/view/1065
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849398680060166144
author M. A. Korotkevich
A. L. Starzhinskij
author_facet M. A. Korotkevich
A. L. Starzhinskij
author_sort M. A. Korotkevich
collection DOAJ
description The reliability of the main circuit of electrical connections at a nuclear electric power plant that has two units with a capacity of 1,200 MW each has been determined. Reliability, economical, maneuverable properties of the atomic power plant under study are largely determined by its main circuit, so the choice of the circuit for the design and its status in the process of operation occur to be critical objectives. Main electrical connection circuits in nuclear electric power plants are selected on the basis of the schematic networks of the energy system and the land attached to the plant. The circuit of the connection of a nuclear power plant to the grid in the original normal operating modes at all stages of the construction of such a plant should provide the outcome of the full added capacity of a nuclear power plant and the preservation of its stability in the power system without the influence of the emergency system automatics when any outgoing transmission line is disabled. When selecting the main circuit the individual capacity of the installed units and their number are taken into account as well as the order of development of the plant and power supply system; the voltage on which the power of a plant is delivered; a shortcircuit current for switchgear high voltage and the need for their limitation by circuit means; the most power that can be lost when damage to any switch. A model of reliability of the main circuit of electrical connections is designed to detect all types of accidents that are possible at the coincidence of failures of elements with the repair and operational modes that differs in composition and damageability of the equipment, as well as under conditions of the development of accidents due to failure of operation of devices of relay protection and automation.
format Article
id doaj-art-e2d1f2d6a46844a6b3a3c70833ccfb5d
institution Kabale University
issn 1029-7448
2414-0341
language Russian
publishDate 2017-05-01
publisher Belarusian National Technical University
record_format Article
series Известия высших учебных заведений и энергетических объединенний СНГ: Энергетика
spelling doaj-art-e2d1f2d6a46844a6b3a3c70833ccfb5d2025-08-20T03:38:31ZrusBelarusian National Technical UniversityИзвестия высших учебных заведений и энергетических объединенний СНГ: Энергетика1029-74482414-03412017-05-0160319119710.21122/1029-7448-2017-60-3-191-1971029THE ANALYSIS OF STRUCTURAL RELIABILITY OF THE MAIN ELECTRIC CONNECTION CIRCUITS OF NUCLEAR POWER PLANTSM. A. Korotkevich0A. L. Starzhinskij1Belarusian National Technical UniversityBelarusian National Technical UniversityThe reliability of the main circuit of electrical connections at a nuclear electric power plant that has two units with a capacity of 1,200 MW each has been determined. Reliability, economical, maneuverable properties of the atomic power plant under study are largely determined by its main circuit, so the choice of the circuit for the design and its status in the process of operation occur to be critical objectives. Main electrical connection circuits in nuclear electric power plants are selected on the basis of the schematic networks of the energy system and the land attached to the plant. The circuit of the connection of a nuclear power plant to the grid in the original normal operating modes at all stages of the construction of such a plant should provide the outcome of the full added capacity of a nuclear power plant and the preservation of its stability in the power system without the influence of the emergency system automatics when any outgoing transmission line is disabled. When selecting the main circuit the individual capacity of the installed units and their number are taken into account as well as the order of development of the plant and power supply system; the voltage on which the power of a plant is delivered; a shortcircuit current for switchgear high voltage and the need for their limitation by circuit means; the most power that can be lost when damage to any switch. A model of reliability of the main circuit of electrical connections is designed to detect all types of accidents that are possible at the coincidence of failures of elements with the repair and operational modes that differs in composition and damageability of the equipment, as well as under conditions of the development of accidents due to failure of operation of devices of relay protection and automation.https://energy.bntu.by/jour/article/view/1065main circuitelectrical connectionsreliabilitynuclear power plant
spellingShingle M. A. Korotkevich
A. L. Starzhinskij
THE ANALYSIS OF STRUCTURAL RELIABILITY OF THE MAIN ELECTRIC CONNECTION CIRCUITS OF NUCLEAR POWER PLANTS
Известия высших учебных заведений и энергетических объединенний СНГ: Энергетика
main circuit
electrical connections
reliability
nuclear power plant
title THE ANALYSIS OF STRUCTURAL RELIABILITY OF THE MAIN ELECTRIC CONNECTION CIRCUITS OF NUCLEAR POWER PLANTS
title_full THE ANALYSIS OF STRUCTURAL RELIABILITY OF THE MAIN ELECTRIC CONNECTION CIRCUITS OF NUCLEAR POWER PLANTS
title_fullStr THE ANALYSIS OF STRUCTURAL RELIABILITY OF THE MAIN ELECTRIC CONNECTION CIRCUITS OF NUCLEAR POWER PLANTS
title_full_unstemmed THE ANALYSIS OF STRUCTURAL RELIABILITY OF THE MAIN ELECTRIC CONNECTION CIRCUITS OF NUCLEAR POWER PLANTS
title_short THE ANALYSIS OF STRUCTURAL RELIABILITY OF THE MAIN ELECTRIC CONNECTION CIRCUITS OF NUCLEAR POWER PLANTS
title_sort analysis of structural reliability of the main electric connection circuits of nuclear power plants
topic main circuit
electrical connections
reliability
nuclear power plant
url https://energy.bntu.by/jour/article/view/1065
work_keys_str_mv AT makorotkevich theanalysisofstructuralreliabilityofthemainelectricconnectioncircuitsofnuclearpowerplants
AT alstarzhinskij theanalysisofstructuralreliabilityofthemainelectricconnectioncircuitsofnuclearpowerplants
AT makorotkevich analysisofstructuralreliabilityofthemainelectricconnectioncircuitsofnuclearpowerplants
AT alstarzhinskij analysisofstructuralreliabilityofthemainelectricconnectioncircuitsofnuclearpowerplants