Heat Transfer Dynamic Analyses for Recycled-Concrete Wall Combined with Expanded Polystyrene Template
Due to the benefits of pollution reduction, energy saving, and recycling of resources associated with the recycled concrete, together with the apparent thermal storage thermal insulation yield of expandable polystyrene (EPS) template, the heat transfer dynamics of their combination has become a cont...
Saved in:
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
Wiley
2018-01-01
|
Series: | Advances in Materials Science and Engineering |
Online Access: | http://dx.doi.org/10.1155/2018/9692806 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1832564092505686016 |
---|---|
author | Jianhua Li Wenjing Chen |
author_facet | Jianhua Li Wenjing Chen |
author_sort | Jianhua Li |
collection | DOAJ |
description | Due to the benefits of pollution reduction, energy saving, and recycling of resources associated with the recycled concrete, together with the apparent thermal storage thermal insulation yield of expandable polystyrene (EPS) template, the heat transfer dynamics of their combination has become a contemporary study topic. In this research work, an investigation of the heat transfer coefficient (U) of EPS template recycled-concrete shear wall has been carried out. Four different concrete mixtures shear wall samples having different insulation types were developed for the purpose of quantifying their thermal outputs. Both temperature (T) and humidity (H) affection to thermal conductivity coefficient (λ) of reinforced concrete and the EPS template were investigated, correspondingly. The λ0°C (relative variation for a 0°C of temperature variation in T) of cement mortar, recycled-concrete shear wall, and ordinary concrete shear wall were measured being 0.7526, 1.2463, and 1.3750 W·m−1·K−1, respectively. And the λ calculation of EPS was carried out being 0.0396 W·m−1·K−1. A corrected calculation method was put forward to application in practical work that could reflect the real U value in a more precise manner. These results brought to light the fact that the heat preservation output of recycled-concrete shear wall posed to be comparatively more improved than that of ordinary concrete shear wall. We put forth the suggestion for the use of corrected calculation method in the calculation and analysis of U of EPS template recycled-concrete composite shear wall in the climatic conditions of Beijing. The results revealed the fact that the U of EPS template recycled-concrete shear wall was dominantly controlled by the change of thermal conductivity changes of EPS template. The monthly mean U increased with increasing Tout and decreased with decreasing Tout. The smaller the U of the enclosure wall was, the better the thermal stability of the wall was experienced. |
format | Article |
id | doaj-art-e0fb7f14c32e45bfbecc0f1355406247 |
institution | Kabale University |
issn | 1687-8434 1687-8442 |
language | English |
publishDate | 2018-01-01 |
publisher | Wiley |
record_format | Article |
series | Advances in Materials Science and Engineering |
spelling | doaj-art-e0fb7f14c32e45bfbecc0f13554062472025-02-03T01:11:54ZengWileyAdvances in Materials Science and Engineering1687-84341687-84422018-01-01201810.1155/2018/96928069692806Heat Transfer Dynamic Analyses for Recycled-Concrete Wall Combined with Expanded Polystyrene TemplateJianhua Li0Wenjing Chen1Jiyang College, Zhejiang Agriculture and Forestry University, Shaoxing 311800, ChinaJiyang College, Zhejiang Agriculture and Forestry University, Shaoxing 311800, ChinaDue to the benefits of pollution reduction, energy saving, and recycling of resources associated with the recycled concrete, together with the apparent thermal storage thermal insulation yield of expandable polystyrene (EPS) template, the heat transfer dynamics of their combination has become a contemporary study topic. In this research work, an investigation of the heat transfer coefficient (U) of EPS template recycled-concrete shear wall has been carried out. Four different concrete mixtures shear wall samples having different insulation types were developed for the purpose of quantifying their thermal outputs. Both temperature (T) and humidity (H) affection to thermal conductivity coefficient (λ) of reinforced concrete and the EPS template were investigated, correspondingly. The λ0°C (relative variation for a 0°C of temperature variation in T) of cement mortar, recycled-concrete shear wall, and ordinary concrete shear wall were measured being 0.7526, 1.2463, and 1.3750 W·m−1·K−1, respectively. And the λ calculation of EPS was carried out being 0.0396 W·m−1·K−1. A corrected calculation method was put forward to application in practical work that could reflect the real U value in a more precise manner. These results brought to light the fact that the heat preservation output of recycled-concrete shear wall posed to be comparatively more improved than that of ordinary concrete shear wall. We put forth the suggestion for the use of corrected calculation method in the calculation and analysis of U of EPS template recycled-concrete composite shear wall in the climatic conditions of Beijing. The results revealed the fact that the U of EPS template recycled-concrete shear wall was dominantly controlled by the change of thermal conductivity changes of EPS template. The monthly mean U increased with increasing Tout and decreased with decreasing Tout. The smaller the U of the enclosure wall was, the better the thermal stability of the wall was experienced.http://dx.doi.org/10.1155/2018/9692806 |
spellingShingle | Jianhua Li Wenjing Chen Heat Transfer Dynamic Analyses for Recycled-Concrete Wall Combined with Expanded Polystyrene Template Advances in Materials Science and Engineering |
title | Heat Transfer Dynamic Analyses for Recycled-Concrete Wall Combined with Expanded Polystyrene Template |
title_full | Heat Transfer Dynamic Analyses for Recycled-Concrete Wall Combined with Expanded Polystyrene Template |
title_fullStr | Heat Transfer Dynamic Analyses for Recycled-Concrete Wall Combined with Expanded Polystyrene Template |
title_full_unstemmed | Heat Transfer Dynamic Analyses for Recycled-Concrete Wall Combined with Expanded Polystyrene Template |
title_short | Heat Transfer Dynamic Analyses for Recycled-Concrete Wall Combined with Expanded Polystyrene Template |
title_sort | heat transfer dynamic analyses for recycled concrete wall combined with expanded polystyrene template |
url | http://dx.doi.org/10.1155/2018/9692806 |
work_keys_str_mv | AT jianhuali heattransferdynamicanalysesforrecycledconcretewallcombinedwithexpandedpolystyrenetemplate AT wenjingchen heattransferdynamicanalysesforrecycledconcretewallcombinedwithexpandedpolystyrenetemplate |