Influence and optimization of building opening configurations on the performance of enhanced roof ventilation units (ERU): a numerical and orthogonal study

Enhanced roof ventilation units (ERU) can significantly enhance indoor airflow and thermal comfort, but their effectiveness is influenced by building opening configurations. Therefore, the performance of ERU under different building opening factors (window height (A), window size (B), door size (C),...

Full description

Saved in:
Bibliographic Details
Main Authors: Lei Tian, Zu-An Liu, You Li, Jiawen Hou, Yuling Xiao, Fan Fei, Yueqiu Xia, Wanxiang Yao, Hiroatsu Fukuda
Format: Article
Language:English
Published: Elsevier 2025-02-01
Series:Case Studies in Thermal Engineering
Subjects:
Online Access:http://www.sciencedirect.com/science/article/pii/S2214157X25000139
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832573253551390720
author Lei Tian
Zu-An Liu
You Li
Jiawen Hou
Yuling Xiao
Fan Fei
Yueqiu Xia
Wanxiang Yao
Hiroatsu Fukuda
author_facet Lei Tian
Zu-An Liu
You Li
Jiawen Hou
Yuling Xiao
Fan Fei
Yueqiu Xia
Wanxiang Yao
Hiroatsu Fukuda
author_sort Lei Tian
collection DOAJ
description Enhanced roof ventilation units (ERU) can significantly enhance indoor airflow and thermal comfort, but their effectiveness is influenced by building opening configurations. Therefore, the performance of ERU under different building opening factors (window height (A), window size (B), door size (C), window orientation (D), door orientation (G), and building orientation (O)) was explored through numerical simulations and orthogonal design. Meanwhile, these factors influence laws, degrees, significance levels, and optimal schemes were identified. The findings reveal that: (1) For volume flow rate, the influence ranking is O > C > B > D > G > A, while for outlet average air age and volume air age, the rankings are O > G > A > D > C > B and O > A > G > C > D > B; (2) The indoor combinatorial ventilation efficiency under optimal configuration is 9.75 %, the flow purification rate and air exchange efficiency are 20.21 % and 48.27 %; (3) The percentage dissatisfied (PDT and PDD) under optimal configuration are 0.31 %; (4) Local vortices can lead to poor ventilation performance, but indoor circulation can bring the air exchange efficiency approaching the ideal 50 %. (5) The opening configurations focus on building orientation and dominant wind direction. (6) Appropriate opening configurations are more conducive to ventilation than increasing the area openings. This research provides valuable insights for optimizing roof ventilation units and improving indoor thermal comfort.
format Article
id doaj-art-e0d5dc51c43a44b09853f53c857b3a95
institution Kabale University
issn 2214-157X
language English
publishDate 2025-02-01
publisher Elsevier
record_format Article
series Case Studies in Thermal Engineering
spelling doaj-art-e0d5dc51c43a44b09853f53c857b3a952025-02-02T05:27:21ZengElsevierCase Studies in Thermal Engineering2214-157X2025-02-0166105753Influence and optimization of building opening configurations on the performance of enhanced roof ventilation units (ERU): a numerical and orthogonal studyLei Tian0Zu-An Liu1You Li2Jiawen Hou3Yuling Xiao4Fan Fei5Yueqiu Xia6Wanxiang Yao7Hiroatsu Fukuda8School of Civil Engineering, Xuzhou University of Technology, Xuzhou, 221018, China; Faculty of Environmental Engineering, The University of Kitakyushu, Kitakyushu, 808-0135, JapanSchool of Civil Engineering, Xuzhou University of Technology, Xuzhou, 221018, China; Corresponding author.Asia-Japan Research Institute, Ritsumeikan University, Ibaraki, 567-8570, JapanSchool of Civil Engineering, Xuzhou University of Technology, Xuzhou, 221018, China; Corresponding author.Faculty of Environmental Engineering, The University of Kitakyushu, Kitakyushu, 808-0135, JapanFaculty of Environmental Engineering, The University of Kitakyushu, Kitakyushu, 808-0135, JapanFaculty of Environmental Engineering, The University of Kitakyushu, Kitakyushu, 808-0135, JapanFaculty of Environmental Engineering, The University of Kitakyushu, Kitakyushu, 808-0135, Japan; iSMART, Qingdao University of Technology, Qingdao, 266033, ChinaFaculty of Environmental Engineering, The University of Kitakyushu, Kitakyushu, 808-0135, JapanEnhanced roof ventilation units (ERU) can significantly enhance indoor airflow and thermal comfort, but their effectiveness is influenced by building opening configurations. Therefore, the performance of ERU under different building opening factors (window height (A), window size (B), door size (C), window orientation (D), door orientation (G), and building orientation (O)) was explored through numerical simulations and orthogonal design. Meanwhile, these factors influence laws, degrees, significance levels, and optimal schemes were identified. The findings reveal that: (1) For volume flow rate, the influence ranking is O > C > B > D > G > A, while for outlet average air age and volume air age, the rankings are O > G > A > D > C > B and O > A > G > C > D > B; (2) The indoor combinatorial ventilation efficiency under optimal configuration is 9.75 %, the flow purification rate and air exchange efficiency are 20.21 % and 48.27 %; (3) The percentage dissatisfied (PDT and PDD) under optimal configuration are 0.31 %; (4) Local vortices can lead to poor ventilation performance, but indoor circulation can bring the air exchange efficiency approaching the ideal 50 %. (5) The opening configurations focus on building orientation and dominant wind direction. (6) Appropriate opening configurations are more conducive to ventilation than increasing the area openings. This research provides valuable insights for optimizing roof ventilation units and improving indoor thermal comfort.http://www.sciencedirect.com/science/article/pii/S2214157X25000139Enhanced roof ventilation unit (ERU)Building opening configurationOrthogonal designNumerical simulationVentilation effect
spellingShingle Lei Tian
Zu-An Liu
You Li
Jiawen Hou
Yuling Xiao
Fan Fei
Yueqiu Xia
Wanxiang Yao
Hiroatsu Fukuda
Influence and optimization of building opening configurations on the performance of enhanced roof ventilation units (ERU): a numerical and orthogonal study
Case Studies in Thermal Engineering
Enhanced roof ventilation unit (ERU)
Building opening configuration
Orthogonal design
Numerical simulation
Ventilation effect
title Influence and optimization of building opening configurations on the performance of enhanced roof ventilation units (ERU): a numerical and orthogonal study
title_full Influence and optimization of building opening configurations on the performance of enhanced roof ventilation units (ERU): a numerical and orthogonal study
title_fullStr Influence and optimization of building opening configurations on the performance of enhanced roof ventilation units (ERU): a numerical and orthogonal study
title_full_unstemmed Influence and optimization of building opening configurations on the performance of enhanced roof ventilation units (ERU): a numerical and orthogonal study
title_short Influence and optimization of building opening configurations on the performance of enhanced roof ventilation units (ERU): a numerical and orthogonal study
title_sort influence and optimization of building opening configurations on the performance of enhanced roof ventilation units eru a numerical and orthogonal study
topic Enhanced roof ventilation unit (ERU)
Building opening configuration
Orthogonal design
Numerical simulation
Ventilation effect
url http://www.sciencedirect.com/science/article/pii/S2214157X25000139
work_keys_str_mv AT leitian influenceandoptimizationofbuildingopeningconfigurationsontheperformanceofenhancedroofventilationunitseruanumericalandorthogonalstudy
AT zuanliu influenceandoptimizationofbuildingopeningconfigurationsontheperformanceofenhancedroofventilationunitseruanumericalandorthogonalstudy
AT youli influenceandoptimizationofbuildingopeningconfigurationsontheperformanceofenhancedroofventilationunitseruanumericalandorthogonalstudy
AT jiawenhou influenceandoptimizationofbuildingopeningconfigurationsontheperformanceofenhancedroofventilationunitseruanumericalandorthogonalstudy
AT yulingxiao influenceandoptimizationofbuildingopeningconfigurationsontheperformanceofenhancedroofventilationunitseruanumericalandorthogonalstudy
AT fanfei influenceandoptimizationofbuildingopeningconfigurationsontheperformanceofenhancedroofventilationunitseruanumericalandorthogonalstudy
AT yueqiuxia influenceandoptimizationofbuildingopeningconfigurationsontheperformanceofenhancedroofventilationunitseruanumericalandorthogonalstudy
AT wanxiangyao influenceandoptimizationofbuildingopeningconfigurationsontheperformanceofenhancedroofventilationunitseruanumericalandorthogonalstudy
AT hiroatsufukuda influenceandoptimizationofbuildingopeningconfigurationsontheperformanceofenhancedroofventilationunitseruanumericalandorthogonalstudy