Stability of small incision lenticule extraction over laser in situ keratomileusis at an altitude of 3874 m

Abstract The purpose of this study was to evaluate the stability of small-incision lenticule extraction (SMILE) and laser in situ keratomileusis (LASIK) when ascending from near sea level to an altitude of 3874 m. The visual acuity (VA), intraocular pressure (IOP), spherical equivalent refraction (S...

Full description

Saved in:
Bibliographic Details
Main Authors: Yanming Huang, Yuancheng Zhao, Xiaofan Chen, Huan zou, Rongdi Yuan
Format: Article
Language:English
Published: Nature Portfolio 2025-01-01
Series:Scientific Reports
Subjects:
Online Access:https://doi.org/10.1038/s41598-025-85740-6
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832594725672058880
author Yanming Huang
Yuancheng Zhao
Xiaofan Chen
Huan zou
Rongdi Yuan
author_facet Yanming Huang
Yuancheng Zhao
Xiaofan Chen
Huan zou
Rongdi Yuan
author_sort Yanming Huang
collection DOAJ
description Abstract The purpose of this study was to evaluate the stability of small-incision lenticule extraction (SMILE) and laser in situ keratomileusis (LASIK) when ascending from near sea level to an altitude of 3874 m. The visual acuity (VA), intraocular pressure (IOP), spherical equivalent refraction (SER) and biometric parameters of 20 normal subjects (40 eyes, controls) and 36 subjects who underwent corneal refractive surgery (35 eyes with SMILE and 36 eyes with LASIK) were examined in Chongqing (C, 500 m above sea level) and 7–10 days after a collective travel to Shigatse (S, 3874 m above sea level). SER and corneal thickness (CT) were choosed as main indicators of the stability of corneal refractive surgery at high altitude. The IOP decreased and CT increased from C to S, while VA and SER did not significantly change in the control subjects. The VA and IOP of both the SMILE and LASIK subjects did not significantly change at an altitude of 3874 m. At high altitudes, no significant difference in the SER was found among the SMILE subjects, while a significant myopic shift was found among the LASIK subjects. With an increase in the altitude of 3874 m in S, an obvious increase in CT was observed in subjects who underwent corneal refraction surgery. The increase in CT in the SMILE group was significantly less than the increase in CT in the LASIK group. In addition, the biometric parameters of the SMILE and LASIK subjects showed the same minor changes as those of the control subjects when exposed to high altitude. The VA, IOP and biometric parameters of the subjects who underwent SMILE and LASIK remained stable at an altitude of 3874 m. SMILE shows better stability than LASIK in the refractive state and CT when exposed to high altitude. Trial registration: This study was approved by the Ethics Committee of The Second Affiliated Hospital of Army Medical University (ID: 2022-No.084-1) and adhered to the principles of the Declaration of Helsinki. The study was registered at http://www.chictr.org.cn (Study NO. ChiCTR2200059833) on 12/5/2022.
format Article
id doaj-art-dfb7394657024bfca2a0cdc53a58abc5
institution Kabale University
issn 2045-2322
language English
publishDate 2025-01-01
publisher Nature Portfolio
record_format Article
series Scientific Reports
spelling doaj-art-dfb7394657024bfca2a0cdc53a58abc52025-01-19T12:24:17ZengNature PortfolioScientific Reports2045-23222025-01-011511810.1038/s41598-025-85740-6Stability of small incision lenticule extraction over laser in situ keratomileusis at an altitude of 3874 mYanming Huang0Yuancheng Zhao1Xiaofan Chen2Huan zou3Rongdi Yuan4Xinqiao Hospital, Army Medical UniversityGeneral Hospital of Western Theater CommandXinqiao Hospital, Army Medical UniversityXinqiao Hospital, Army Medical UniversityXinqiao Hospital, Army Medical UniversityAbstract The purpose of this study was to evaluate the stability of small-incision lenticule extraction (SMILE) and laser in situ keratomileusis (LASIK) when ascending from near sea level to an altitude of 3874 m. The visual acuity (VA), intraocular pressure (IOP), spherical equivalent refraction (SER) and biometric parameters of 20 normal subjects (40 eyes, controls) and 36 subjects who underwent corneal refractive surgery (35 eyes with SMILE and 36 eyes with LASIK) were examined in Chongqing (C, 500 m above sea level) and 7–10 days after a collective travel to Shigatse (S, 3874 m above sea level). SER and corneal thickness (CT) were choosed as main indicators of the stability of corneal refractive surgery at high altitude. The IOP decreased and CT increased from C to S, while VA and SER did not significantly change in the control subjects. The VA and IOP of both the SMILE and LASIK subjects did not significantly change at an altitude of 3874 m. At high altitudes, no significant difference in the SER was found among the SMILE subjects, while a significant myopic shift was found among the LASIK subjects. With an increase in the altitude of 3874 m in S, an obvious increase in CT was observed in subjects who underwent corneal refraction surgery. The increase in CT in the SMILE group was significantly less than the increase in CT in the LASIK group. In addition, the biometric parameters of the SMILE and LASIK subjects showed the same minor changes as those of the control subjects when exposed to high altitude. The VA, IOP and biometric parameters of the subjects who underwent SMILE and LASIK remained stable at an altitude of 3874 m. SMILE shows better stability than LASIK in the refractive state and CT when exposed to high altitude. Trial registration: This study was approved by the Ethics Committee of The Second Affiliated Hospital of Army Medical University (ID: 2022-No.084-1) and adhered to the principles of the Declaration of Helsinki. The study was registered at http://www.chictr.org.cn (Study NO. ChiCTR2200059833) on 12/5/2022.https://doi.org/10.1038/s41598-025-85740-6Refractive surgeryCorneal thicknessRefractive statusHigh altitude
spellingShingle Yanming Huang
Yuancheng Zhao
Xiaofan Chen
Huan zou
Rongdi Yuan
Stability of small incision lenticule extraction over laser in situ keratomileusis at an altitude of 3874 m
Scientific Reports
Refractive surgery
Corneal thickness
Refractive status
High altitude
title Stability of small incision lenticule extraction over laser in situ keratomileusis at an altitude of 3874 m
title_full Stability of small incision lenticule extraction over laser in situ keratomileusis at an altitude of 3874 m
title_fullStr Stability of small incision lenticule extraction over laser in situ keratomileusis at an altitude of 3874 m
title_full_unstemmed Stability of small incision lenticule extraction over laser in situ keratomileusis at an altitude of 3874 m
title_short Stability of small incision lenticule extraction over laser in situ keratomileusis at an altitude of 3874 m
title_sort stability of small incision lenticule extraction over laser in situ keratomileusis at an altitude of 3874 m
topic Refractive surgery
Corneal thickness
Refractive status
High altitude
url https://doi.org/10.1038/s41598-025-85740-6
work_keys_str_mv AT yanminghuang stabilityofsmallincisionlenticuleextractionoverlaserinsitukeratomileusisatanaltitudeof3874m
AT yuanchengzhao stabilityofsmallincisionlenticuleextractionoverlaserinsitukeratomileusisatanaltitudeof3874m
AT xiaofanchen stabilityofsmallincisionlenticuleextractionoverlaserinsitukeratomileusisatanaltitudeof3874m
AT huanzou stabilityofsmallincisionlenticuleextractionoverlaserinsitukeratomileusisatanaltitudeof3874m
AT rongdiyuan stabilityofsmallincisionlenticuleextractionoverlaserinsitukeratomileusisatanaltitudeof3874m