Measuring circuits of two double electro-induction spherical sensors of electric field strength of closed type constructively united into a single whole
To control the levels of electric fields, electric field strength sensors are required. Currently, for these purposes, the most promising are dual electric induction sensors, which are a constructive combination of two double sensors into one whole. There are two types of dual sensors with overh...
Saved in:
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Omsk State Technical University, Federal State Autonoumos Educational Institution of Higher Education
2022-04-01
|
Series: | Омский научный вестник |
Subjects: | |
Online Access: | https://www.omgtu.ru/general_information/media_omgtu/journal_of_omsk_research_journal/files/arhiv/2022/%E2%84%96%202%20(182)%20(%D0%9E%D0%9D%D0%92)/93-101%20%D0%91%D0%B8%D1%80%D1%8E%D0%BA%D0%BE%D0%B2%20%D0%A1.%20%D0%92.,%20%D0%A2%D1%8E%D0%BA%D0%B8%D0%BD%D0%B0%20%D0%9B.%20%D0%92.,%20%D0%A2%D1%8E%D0%BA%D0%B8%D0%BD%20%D0%90.%20%D0%92..pdf |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1832570264163975168 |
---|---|
author | S. V. Biryukov L. V. Tyukina A. V. Tyukin |
author_facet | S. V. Biryukov L. V. Tyukina A. V. Tyukin |
author_sort | S. V. Biryukov |
collection | DOAJ |
description | To control the levels of electric fields, electric field
strength sensors are required. Currently, for these purposes, the most promising are dual electric induction
sensors, which are a constructive combination of two
double sensors into one whole. There are two types of
dual sensors with overhead, composite and separate
sensing elements. The output signals of such sensors
are electrical parameters such as charge, current and
voltage. Studies have shown that electrical charge has
the greatest advantage. To remove the charge from the
sensor, it is recommended to use a current integrator
(charge amplifier) as the primary measuring circuit.
Secondary measuring circuits of the dual sensors
considered in this work are used for averaging the
signals of double sensors in order to reduce the error
from the inhomogeneity of the electric field and form
an output signal proportional to the field strength. It
has been established in the work that sensors with
overhead and composite sensitive elements allow to
perceive the intensity of an inhomogeneous electric
field with an error not exceeding +4,6 % in the spatial
measurement range 0a1. The work also determined
the sensitivities of two types of dual sensors of the
electric field strength. |
format | Article |
id | doaj-art-df5bcb245f42447aa27e8035a6fc99cc |
institution | Kabale University |
issn | 1813-8225 2541-7541 |
language | English |
publishDate | 2022-04-01 |
publisher | Omsk State Technical University, Federal State Autonoumos Educational Institution of Higher Education |
record_format | Article |
series | Омский научный вестник |
spelling | doaj-art-df5bcb245f42447aa27e8035a6fc99cc2025-02-02T15:57:40ZengOmsk State Technical University, Federal State Autonoumos Educational Institution of Higher EducationОмский научный вестник1813-82252541-75412022-04-012 (182)9310110.25206/1813-8225-2022-182-93-101Measuring circuits of two double electro-induction spherical sensors of electric field strength of closed type constructively united into a single wholeS. V. Biryukov0https://orcid.org/0000-0002-1362-9911 L. V. Tyukina1A. V. Tyukin2https://orcid.org/0000-0002-7316-3797Omsk State Technical UniversityOmsk State Technical UniversitySiberian State Automobile and Highway UniversityTo control the levels of electric fields, electric field strength sensors are required. Currently, for these purposes, the most promising are dual electric induction sensors, which are a constructive combination of two double sensors into one whole. There are two types of dual sensors with overhead, composite and separate sensing elements. The output signals of such sensors are electrical parameters such as charge, current and voltage. Studies have shown that electrical charge has the greatest advantage. To remove the charge from the sensor, it is recommended to use a current integrator (charge amplifier) as the primary measuring circuit. Secondary measuring circuits of the dual sensors considered in this work are used for averaging the signals of double sensors in order to reduce the error from the inhomogeneity of the electric field and form an output signal proportional to the field strength. It has been established in the work that sensors with overhead and composite sensitive elements allow to perceive the intensity of an inhomogeneous electric field with an error not exceeding +4,6 % in the spatial measurement range 0a1. The work also determined the sensitivities of two types of dual sensors of the electric field strength. https://www.omgtu.ru/general_information/media_omgtu/journal_of_omsk_research_journal/files/arhiv/2022/%E2%84%96%202%20(182)%20(%D0%9E%D0%9D%D0%92)/93-101%20%D0%91%D0%B8%D1%80%D1%8E%D0%BA%D0%BE%D0%B2%20%D0%A1.%20%D0%92.,%20%D0%A2%D1%8E%D0%BA%D0%B8%D0%BD%D0%B0%20%D0%9B.%20%D0%92.,%20%D0%A2%D1%8E%D0%BA%D0%B8%D0%BD%20%D0%90.%20%D0%92..pdfelectric field strengthelectric field strength sensorsingle sensordouble sensortwo double in oneprimary measuring circuits of sensorserror from field inhomogeneitysensor sensitivity |
spellingShingle | S. V. Biryukov L. V. Tyukina A. V. Tyukin Measuring circuits of two double electro-induction spherical sensors of electric field strength of closed type constructively united into a single whole Омский научный вестник electric field strength electric field strength sensor single sensor double sensor two double in one primary measuring circuits of sensors error from field inhomogeneity sensor sensitivity |
title | Measuring circuits of two double electro-induction spherical sensors of electric field strength of closed type constructively united into a single whole |
title_full | Measuring circuits of two double electro-induction spherical sensors of electric field strength of closed type constructively united into a single whole |
title_fullStr | Measuring circuits of two double electro-induction spherical sensors of electric field strength of closed type constructively united into a single whole |
title_full_unstemmed | Measuring circuits of two double electro-induction spherical sensors of electric field strength of closed type constructively united into a single whole |
title_short | Measuring circuits of two double electro-induction spherical sensors of electric field strength of closed type constructively united into a single whole |
title_sort | measuring circuits of two double electro induction spherical sensors of electric field strength of closed type constructively united into a single whole |
topic | electric field strength electric field strength sensor single sensor double sensor two double in one primary measuring circuits of sensors error from field inhomogeneity sensor sensitivity |
url | https://www.omgtu.ru/general_information/media_omgtu/journal_of_omsk_research_journal/files/arhiv/2022/%E2%84%96%202%20(182)%20(%D0%9E%D0%9D%D0%92)/93-101%20%D0%91%D0%B8%D1%80%D1%8E%D0%BA%D0%BE%D0%B2%20%D0%A1.%20%D0%92.,%20%D0%A2%D1%8E%D0%BA%D0%B8%D0%BD%D0%B0%20%D0%9B.%20%D0%92.,%20%D0%A2%D1%8E%D0%BA%D0%B8%D0%BD%20%D0%90.%20%D0%92..pdf |
work_keys_str_mv | AT svbiryukov measuringcircuitsoftwodoubleelectroinductionsphericalsensorsofelectricfieldstrengthofclosedtypeconstructivelyunitedintoasinglewhole AT lvtyukina measuringcircuitsoftwodoubleelectroinductionsphericalsensorsofelectricfieldstrengthofclosedtypeconstructivelyunitedintoasinglewhole AT avtyukin measuringcircuitsoftwodoubleelectroinductionsphericalsensorsofelectricfieldstrengthofclosedtypeconstructivelyunitedintoasinglewhole |