Ion-Selective Electrode for Anionic Surfactants Using Hexadecyl Trimethyl Ammonium Bromide-Sodium Dodecylsulfate as an Active Ionophore

The construction and characteristic performance of PVC membrane electrode responsive to sodium dodecylsulfate (SDS) are described in this paper. The electrode is based on hexadecyl trimethyl ammonium bromi...

Full description

Saved in:
Bibliographic Details
Main Authors: Junwei Wang, Zhiping Du, Wanxu Wang, Wei Xue
Format: Article
Language:English
Published: Wiley 2011-01-01
Series:International Journal of Electrochemistry
Online Access:http://dx.doi.org/10.4061/2011/958647
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832554046889656320
author Junwei Wang
Zhiping Du
Wanxu Wang
Wei Xue
author_facet Junwei Wang
Zhiping Du
Wanxu Wang
Wei Xue
author_sort Junwei Wang
collection DOAJ
description The construction and characteristic performance of PVC membrane electrode responsive to sodium dodecylsulfate (SDS) are described in this paper. The electrode is based on hexadecyl trimethyl ammonium bromide-Sodium dodecylsulfate (CTA+DS−) ion pair as ionophore in PVC membrane, which displays a Nernstian slope of −58 ± 0.9 mV/decade in a 5.0 × 10−6 to 2.5 × 10−3 mol L−1 concentration range and a limit of detection of 2.9 × 10−6 mol L−1. The electrode can be used for 3 months without showing significant changes in the value of slope or working range. Also the electrode has wide pH range of application and short response time. The electrode shows a selective response to SDS and a poor response to common inorganic anions. The selective sequence found was SDS > HCO3 − > CH3COO− > Cl− > I− > NO3 −≈ Br− > F− > CO3 2− > C6H5O7 3− > C2O4 2− > SO4 2− > C4H4O6 2− > SO3 2− > PO4 3−. The potentiometric selectivity coefficients determined are indicating that common anions would not interfere in the SDS determination. The electrode has been utilized as an end point indicator electrode for potentiometric titration involving hyamine as titrant.
format Article
id doaj-art-df0240d079be48ada7e175ab535969f2
institution Kabale University
issn 2090-3537
language English
publishDate 2011-01-01
publisher Wiley
record_format Article
series International Journal of Electrochemistry
spelling doaj-art-df0240d079be48ada7e175ab535969f22025-02-03T05:52:33ZengWileyInternational Journal of Electrochemistry2090-35372011-01-01201110.4061/2011/958647958647Ion-Selective Electrode for Anionic Surfactants Using Hexadecyl Trimethyl Ammonium Bromide-Sodium Dodecylsulfate as an Active IonophoreJunwei Wang0Zhiping Du1Wanxu Wang2Wei Xue3Key Laboratory of Surfactant and Interfaces, China Research Institute of Daily Chemical Industry, Shanxi Province, Taiyuan 030001, ChinaKey Laboratory of Surfactant and Interfaces, China Research Institute of Daily Chemical Industry, Shanxi Province, Taiyuan 030001, ChinaKey Laboratory of Surfactant and Interfaces, China Research Institute of Daily Chemical Industry, Shanxi Province, Taiyuan 030001, ChinaKey Laboratory of Surfactant and Interfaces, China Research Institute of Daily Chemical Industry, Shanxi Province, Taiyuan 030001, ChinaThe construction and characteristic performance of PVC membrane electrode responsive to sodium dodecylsulfate (SDS) are described in this paper. The electrode is based on hexadecyl trimethyl ammonium bromide-Sodium dodecylsulfate (CTA+DS−) ion pair as ionophore in PVC membrane, which displays a Nernstian slope of −58 ± 0.9 mV/decade in a 5.0 × 10−6 to 2.5 × 10−3 mol L−1 concentration range and a limit of detection of 2.9 × 10−6 mol L−1. The electrode can be used for 3 months without showing significant changes in the value of slope or working range. Also the electrode has wide pH range of application and short response time. The electrode shows a selective response to SDS and a poor response to common inorganic anions. The selective sequence found was SDS > HCO3 − > CH3COO− > Cl− > I− > NO3 −≈ Br− > F− > CO3 2− > C6H5O7 3− > C2O4 2− > SO4 2− > C4H4O6 2− > SO3 2− > PO4 3−. The potentiometric selectivity coefficients determined are indicating that common anions would not interfere in the SDS determination. The electrode has been utilized as an end point indicator electrode for potentiometric titration involving hyamine as titrant.http://dx.doi.org/10.4061/2011/958647
spellingShingle Junwei Wang
Zhiping Du
Wanxu Wang
Wei Xue
Ion-Selective Electrode for Anionic Surfactants Using Hexadecyl Trimethyl Ammonium Bromide-Sodium Dodecylsulfate as an Active Ionophore
International Journal of Electrochemistry
title Ion-Selective Electrode for Anionic Surfactants Using Hexadecyl Trimethyl Ammonium Bromide-Sodium Dodecylsulfate as an Active Ionophore
title_full Ion-Selective Electrode for Anionic Surfactants Using Hexadecyl Trimethyl Ammonium Bromide-Sodium Dodecylsulfate as an Active Ionophore
title_fullStr Ion-Selective Electrode for Anionic Surfactants Using Hexadecyl Trimethyl Ammonium Bromide-Sodium Dodecylsulfate as an Active Ionophore
title_full_unstemmed Ion-Selective Electrode for Anionic Surfactants Using Hexadecyl Trimethyl Ammonium Bromide-Sodium Dodecylsulfate as an Active Ionophore
title_short Ion-Selective Electrode for Anionic Surfactants Using Hexadecyl Trimethyl Ammonium Bromide-Sodium Dodecylsulfate as an Active Ionophore
title_sort ion selective electrode for anionic surfactants using hexadecyl trimethyl ammonium bromide sodium dodecylsulfate as an active ionophore
url http://dx.doi.org/10.4061/2011/958647
work_keys_str_mv AT junweiwang ionselectiveelectrodeforanionicsurfactantsusinghexadecyltrimethylammoniumbromidesodiumdodecylsulfateasanactiveionophore
AT zhipingdu ionselectiveelectrodeforanionicsurfactantsusinghexadecyltrimethylammoniumbromidesodiumdodecylsulfateasanactiveionophore
AT wanxuwang ionselectiveelectrodeforanionicsurfactantsusinghexadecyltrimethylammoniumbromidesodiumdodecylsulfateasanactiveionophore
AT weixue ionselectiveelectrodeforanionicsurfactantsusinghexadecyltrimethylammoniumbromidesodiumdodecylsulfateasanactiveionophore