Ion-Selective Electrode for Anionic Surfactants Using Hexadecyl Trimethyl Ammonium Bromide-Sodium Dodecylsulfate as an Active Ionophore
The construction and characteristic performance of PVC membrane electrode responsive to sodium dodecylsulfate (SDS) are described in this paper. The electrode is based on hexadecyl trimethyl ammonium bromi...
Saved in:
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Wiley
2011-01-01
|
Series: | International Journal of Electrochemistry |
Online Access: | http://dx.doi.org/10.4061/2011/958647 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1832554046889656320 |
---|---|
author | Junwei Wang Zhiping Du Wanxu Wang Wei Xue |
author_facet | Junwei Wang Zhiping Du Wanxu Wang Wei Xue |
author_sort | Junwei Wang |
collection | DOAJ |
description | The construction and
characteristic performance of PVC membrane
electrode responsive to sodium dodecylsulfate
(SDS) are described in this paper. The electrode
is based on hexadecyl trimethyl ammonium
bromide-Sodium dodecylsulfate (CTA+DS−) ion pair as ionophore in PVC membrane, which displays a Nernstian slope of −58 ± 0.9 mV/decade in a 5.0 × 10−6 to 2.5 × 10−3 mol L−1 concentration range and a limit of detection of 2.9 × 10−6 mol L−1. The electrode can be used for 3 months without showing significant changes in the value of slope or working range. Also the electrode has wide pH range of application and short response time. The electrode shows a selective response to SDS and a poor response to common inorganic anions. The selective sequence found was SDS > HCO3 − > CH3COO− > Cl− > I− > NO3 −≈ Br− > F− > CO3 2− > C6H5O7 3− > C2O4 2− > SO4 2− > C4H4O6 2− > SO3 2− > PO4 3−. The potentiometric selectivity coefficients
determined are indicating that common anions would not interfere
in the SDS determination. The electrode has been utilized as an
end point indicator electrode for potentiometric titration
involving hyamine as titrant. |
format | Article |
id | doaj-art-df0240d079be48ada7e175ab535969f2 |
institution | Kabale University |
issn | 2090-3537 |
language | English |
publishDate | 2011-01-01 |
publisher | Wiley |
record_format | Article |
series | International Journal of Electrochemistry |
spelling | doaj-art-df0240d079be48ada7e175ab535969f22025-02-03T05:52:33ZengWileyInternational Journal of Electrochemistry2090-35372011-01-01201110.4061/2011/958647958647Ion-Selective Electrode for Anionic Surfactants Using Hexadecyl Trimethyl Ammonium Bromide-Sodium Dodecylsulfate as an Active IonophoreJunwei Wang0Zhiping Du1Wanxu Wang2Wei Xue3Key Laboratory of Surfactant and Interfaces, China Research Institute of Daily Chemical Industry, Shanxi Province, Taiyuan 030001, ChinaKey Laboratory of Surfactant and Interfaces, China Research Institute of Daily Chemical Industry, Shanxi Province, Taiyuan 030001, ChinaKey Laboratory of Surfactant and Interfaces, China Research Institute of Daily Chemical Industry, Shanxi Province, Taiyuan 030001, ChinaKey Laboratory of Surfactant and Interfaces, China Research Institute of Daily Chemical Industry, Shanxi Province, Taiyuan 030001, ChinaThe construction and characteristic performance of PVC membrane electrode responsive to sodium dodecylsulfate (SDS) are described in this paper. The electrode is based on hexadecyl trimethyl ammonium bromide-Sodium dodecylsulfate (CTA+DS−) ion pair as ionophore in PVC membrane, which displays a Nernstian slope of −58 ± 0.9 mV/decade in a 5.0 × 10−6 to 2.5 × 10−3 mol L−1 concentration range and a limit of detection of 2.9 × 10−6 mol L−1. The electrode can be used for 3 months without showing significant changes in the value of slope or working range. Also the electrode has wide pH range of application and short response time. The electrode shows a selective response to SDS and a poor response to common inorganic anions. The selective sequence found was SDS > HCO3 − > CH3COO− > Cl− > I− > NO3 −≈ Br− > F− > CO3 2− > C6H5O7 3− > C2O4 2− > SO4 2− > C4H4O6 2− > SO3 2− > PO4 3−. The potentiometric selectivity coefficients determined are indicating that common anions would not interfere in the SDS determination. The electrode has been utilized as an end point indicator electrode for potentiometric titration involving hyamine as titrant.http://dx.doi.org/10.4061/2011/958647 |
spellingShingle | Junwei Wang Zhiping Du Wanxu Wang Wei Xue Ion-Selective Electrode for Anionic Surfactants Using Hexadecyl Trimethyl Ammonium Bromide-Sodium Dodecylsulfate as an Active Ionophore International Journal of Electrochemistry |
title | Ion-Selective Electrode for Anionic Surfactants Using Hexadecyl Trimethyl Ammonium Bromide-Sodium Dodecylsulfate as an Active Ionophore |
title_full | Ion-Selective Electrode for Anionic Surfactants Using Hexadecyl Trimethyl Ammonium Bromide-Sodium Dodecylsulfate as an Active Ionophore |
title_fullStr | Ion-Selective Electrode for Anionic Surfactants Using Hexadecyl Trimethyl Ammonium Bromide-Sodium Dodecylsulfate as an Active Ionophore |
title_full_unstemmed | Ion-Selective Electrode for Anionic Surfactants Using Hexadecyl Trimethyl Ammonium Bromide-Sodium Dodecylsulfate as an Active Ionophore |
title_short | Ion-Selective Electrode for Anionic Surfactants Using Hexadecyl Trimethyl Ammonium Bromide-Sodium Dodecylsulfate as an Active Ionophore |
title_sort | ion selective electrode for anionic surfactants using hexadecyl trimethyl ammonium bromide sodium dodecylsulfate as an active ionophore |
url | http://dx.doi.org/10.4061/2011/958647 |
work_keys_str_mv | AT junweiwang ionselectiveelectrodeforanionicsurfactantsusinghexadecyltrimethylammoniumbromidesodiumdodecylsulfateasanactiveionophore AT zhipingdu ionselectiveelectrodeforanionicsurfactantsusinghexadecyltrimethylammoniumbromidesodiumdodecylsulfateasanactiveionophore AT wanxuwang ionselectiveelectrodeforanionicsurfactantsusinghexadecyltrimethylammoniumbromidesodiumdodecylsulfateasanactiveionophore AT weixue ionselectiveelectrodeforanionicsurfactantsusinghexadecyltrimethylammoniumbromidesodiumdodecylsulfateasanactiveionophore |