Optimization and Damping Performance of a Coal-Fired Power Plant Building Equipped with Multiple Coal Bucket Dampers
A parameter optimization design method is proposed for multiple coal bucket dampers (CBDs) to reduce the seismic response of coal-fired power plants. To test the damping effect of the optimized CBDs, a 1 : 30 scale shaking table test model of a power plant structure was fabricated. A comparative tes...
Saved in:
Main Authors: | Ling-Yun Peng, Ying-Jie Kang, Zong-Rui Lai, Yu-Ke Deng |
---|---|
Format: | Article |
Language: | English |
Published: |
Wiley
2018-01-01
|
Series: | Advances in Civil Engineering |
Online Access: | http://dx.doi.org/10.1155/2018/7015019 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Similar Items
-
Optimisation Design and Damping Effect Analysis of Large Mass Ratio Tuned Mass Dampers
by: Ying-jie Kang, et al.
Published: (2019-01-01) -
Ash Evaluation of Indonesian Coal Blending for Pulverized Coal-Fired Boilers
by: null Hariana, et al.
Published: (2021-01-01) -
Analysis of natural radionuclides in coal, slag and ash in coal-fired power plants in Serbia
by: Janković M.M., et al.
Published: (2011-01-01) -
Preparation and Stability of Inorganic Solidified Foam for Preventing Coal Fires
by: Botao Qin, et al.
Published: (2014-01-01) -
Tuning of a Viscous Inerter Damper: How to Achieve Resonant Damping Without a Damper Resonance
by: Jan Høgsberg