Effect of Implant Positions and Angulations on Retentive Strength of 2-Implant Mandibular Overdentures: An In Vitro Study with the New 3D-Printed Simulation Method
Objectives. To evaluate the retentive strength of overdenture attachments in 2-implant mandibular overdenture (2IMO) with implants placed at different positions and angulations. Materials and Methods. Edentulous mandibular models were 3D-printed using CBCT images and Materialise Mimics software and...
Saved in:
Main Authors: | Pravinkumar G. Patil, Liang Lin Seow, Rashmi Uddanwadikar, Allan Pau, Piyush D. Ukey |
---|---|
Format: | Article |
Language: | English |
Published: |
Wiley
2022-01-01
|
Series: | International Journal of Dentistry |
Online Access: | http://dx.doi.org/10.1155/2022/7052955 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Similar Items
-
Retention of CAD-CAM locator retentive attachment insert in mandibular implant overdenture
by: Mai Hassan Diab, et al.
Published: (2025-01-01) -
Implant Stability Changes for Nonsubmerged and Submerged Protocols for a Single Implant Mandibular Overdenture Using Ball Attachment
by: Ahmed Salah, et al.
Published: (2021-01-01) -
A Prospective Study of Early Loaded Single Implant-Retained Mandibular Overdentures: Preliminary One-Year Results
by: Ali M. El-Sheikh, et al.
Published: (2012-01-01) -
Masticatory Ability for a Single Implant Mandibular Overdenture Retained by Two Different Attachments: A Randomized Controlled Trial
by: Marwa Abdel AaL, et al.
Published: (2021-01-01) -
Incorporating Stud Attachments in the Bar Design for an Implant-Supported Overdenture
by: Dimokritos Papalexopoulos, et al.
Published: (2024-01-01)