Application of Geo-thermal Response Test in the Design of Ground-source Heat Pump System

Combining with a ground source heat pump project in Nanjing, the key issues of Geo-thermal response test are analyzed and the normative test methods and steps are summarized. Vertical double U-tube test wells are taken as testing apparatus, and local soil thermal parameters are collected through fie...

Full description

Saved in:
Bibliographic Details
Main Authors: Hao Xiaochong, Yu Yuejin, Mao Bingwen, Hu Chunliang, Zhang Hailin
Format: Article
Language:zho
Published: Journal of Refrigeration Magazines Agency Co., Ltd. 2011-01-01
Series:Zhileng xuebao
Subjects:
Online Access:http://www.zhilengxuebao.com/thesisDetails#10.3969/j.issn.0253-4339.2011.06.044
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1850027365145509888
author Hao Xiaochong
Yu Yuejin
Mao Bingwen
Hu Chunliang
Zhang Hailin
author_facet Hao Xiaochong
Yu Yuejin
Mao Bingwen
Hu Chunliang
Zhang Hailin
author_sort Hao Xiaochong
collection DOAJ
description Combining with a ground source heat pump project in Nanjing, the key issues of Geo-thermal response test are analyzed and the normative test methods and steps are summarized. Vertical double U-tube test wells are taken as testing apparatus, and local soil thermal parameters are collected through field test of two test wells with depth of 100m. Furthermore, the original ground temperature and the inlet and outlet water temperature response curve of the underground heat exchanger are also obtained, which are used to determine the heat exchange quantity of per well depth and other parameters. It is concluded from data analysis: the original ground temperature is 17.95℃; the heat exchange quantity of per well depth is 69.6W/m under summer conditions (35℃) and 51.2W/m under winter conditions (5℃). All of those conclusions prove that comprehensive geological conditions of the project area are suitable for the use of ground source heat pump air conditioning system.
format Article
id doaj-art-d98e4b8fc1a64bb6ac2c8b26bc7e4872
institution DOAJ
issn 0253-4339
language zho
publishDate 2011-01-01
publisher Journal of Refrigeration Magazines Agency Co., Ltd.
record_format Article
series Zhileng xuebao
spelling doaj-art-d98e4b8fc1a64bb6ac2c8b26bc7e48722025-08-20T03:00:13ZzhoJournal of Refrigeration Magazines Agency Co., Ltd.Zhileng xuebao0253-43392011-01-013266519526Application of Geo-thermal Response Test in the Design of Ground-source Heat Pump SystemHao XiaochongYu YuejinMao BingwenHu ChunliangZhang HailinCombining with a ground source heat pump project in Nanjing, the key issues of Geo-thermal response test are analyzed and the normative test methods and steps are summarized. Vertical double U-tube test wells are taken as testing apparatus, and local soil thermal parameters are collected through field test of two test wells with depth of 100m. Furthermore, the original ground temperature and the inlet and outlet water temperature response curve of the underground heat exchanger are also obtained, which are used to determine the heat exchange quantity of per well depth and other parameters. It is concluded from data analysis: the original ground temperature is 17.95℃; the heat exchange quantity of per well depth is 69.6W/m under summer conditions (35℃) and 51.2W/m under winter conditions (5℃). All of those conclusions prove that comprehensive geological conditions of the project area are suitable for the use of ground source heat pump air conditioning system.http://www.zhilengxuebao.com/thesisDetails#10.3969/j.issn.0253-4339.2011.06.044engineering thermophysicsUnderground heat exchange systemGeo-thermal response testEngineering design
spellingShingle Hao Xiaochong
Yu Yuejin
Mao Bingwen
Hu Chunliang
Zhang Hailin
Application of Geo-thermal Response Test in the Design of Ground-source Heat Pump System
Zhileng xuebao
engineering thermophysics
Underground heat exchange system
Geo-thermal response test
Engineering design
title Application of Geo-thermal Response Test in the Design of Ground-source Heat Pump System
title_full Application of Geo-thermal Response Test in the Design of Ground-source Heat Pump System
title_fullStr Application of Geo-thermal Response Test in the Design of Ground-source Heat Pump System
title_full_unstemmed Application of Geo-thermal Response Test in the Design of Ground-source Heat Pump System
title_short Application of Geo-thermal Response Test in the Design of Ground-source Heat Pump System
title_sort application of geo thermal response test in the design of ground source heat pump system
topic engineering thermophysics
Underground heat exchange system
Geo-thermal response test
Engineering design
url http://www.zhilengxuebao.com/thesisDetails#10.3969/j.issn.0253-4339.2011.06.044
work_keys_str_mv AT haoxiaochong applicationofgeothermalresponsetestinthedesignofgroundsourceheatpumpsystem
AT yuyuejin applicationofgeothermalresponsetestinthedesignofgroundsourceheatpumpsystem
AT maobingwen applicationofgeothermalresponsetestinthedesignofgroundsourceheatpumpsystem
AT huchunliang applicationofgeothermalresponsetestinthedesignofgroundsourceheatpumpsystem
AT zhanghailin applicationofgeothermalresponsetestinthedesignofgroundsourceheatpumpsystem