Investigation of Passive Controlled Post-Tensioning System on the Structural Behaviour of Precast Reinforced Concrete Beam–Column Connections
Precast structures are widely used in many parts of the world. This construction technique is more commonly preferred for low-rise industrial buildings than multi-story structures. The most commonly used column–beam connection in precast buildings is the dowel connection (DC). Past earthquakes in va...
Saved in:
| Main Authors: | , |
|---|---|
| Format: | Article |
| Language: | English |
| Published: |
MDPI AG
2024-12-01
|
| Series: | Buildings |
| Subjects: | |
| Online Access: | https://www.mdpi.com/2075-5309/14/12/3910 |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| _version_ | 1850036336825729024 |
|---|---|
| author | Recep Kadir Pekgokgoz Ihsan Yakut |
| author_facet | Recep Kadir Pekgokgoz Ihsan Yakut |
| author_sort | Recep Kadir Pekgokgoz |
| collection | DOAJ |
| description | Precast structures are widely used in many parts of the world. This construction technique is more commonly preferred for low-rise industrial buildings than multi-story structures. The most commonly used column–beam connection in precast buildings is the dowel connection (DC). Past earthquakes in various parts of the world have shown that these connections do not provide sufficient resistance. The main deficiencies of such connections are that they are sheared or stripped due to the shear force demand from the in-plane effects of large earthquakes, and that they do not provide sufficient resistance to the overturning moments from the out-of-plane effects of the earthquakes. Correspondingly, many prefabricated buildings have collapsed during earthquakes, causing loss of life and property. This study proposes using post-tensioning tendon (PT) systems and systems created by adding steel springs (PTS) to eliminate the weaknesses in column–beam connections in precast structures. To this end, real-sized column and beam specimens used in precast buildings were produced, and experiments were conducted under the cyclic loads defined by the American Concrete Institute (ACI) Committee, Report 374, simulating earthquake effects for three different connection types (DC, PT, and PTS). It was observed that the proposed PTS connection type dissipated approximately one-third of the energy transferred to the joint through elastic deformation in the springs, compared to the DC and PT connection types. This indicates that the PTS specimens transferred significantly less energy to the column–beam connection region. Consequently, the PTS system exhibited much less damage in the column foundation and especially the column–beam connection areas than other test specimens. In conclusion, it can be stated that the use of the PTS connection type in prefabricated structures has high potential to reduce damages due to dynamic loads such as earthquakes. |
| format | Article |
| id | doaj-art-d98cfe03d51a4da29b7e14bf6dd91f5b |
| institution | DOAJ |
| issn | 2075-5309 |
| language | English |
| publishDate | 2024-12-01 |
| publisher | MDPI AG |
| record_format | Article |
| series | Buildings |
| spelling | doaj-art-d98cfe03d51a4da29b7e14bf6dd91f5b2025-08-20T02:57:12ZengMDPI AGBuildings2075-53092024-12-011412391010.3390/buildings14123910Investigation of Passive Controlled Post-Tensioning System on the Structural Behaviour of Precast Reinforced Concrete Beam–Column ConnectionsRecep Kadir Pekgokgoz0Ihsan Yakut1Department of Civil Engineering, Harran University, Sanliurfa 63200, TurkeyDepartment of Civil Engineering, Harran University, Sanliurfa 63200, TurkeyPrecast structures are widely used in many parts of the world. This construction technique is more commonly preferred for low-rise industrial buildings than multi-story structures. The most commonly used column–beam connection in precast buildings is the dowel connection (DC). Past earthquakes in various parts of the world have shown that these connections do not provide sufficient resistance. The main deficiencies of such connections are that they are sheared or stripped due to the shear force demand from the in-plane effects of large earthquakes, and that they do not provide sufficient resistance to the overturning moments from the out-of-plane effects of the earthquakes. Correspondingly, many prefabricated buildings have collapsed during earthquakes, causing loss of life and property. This study proposes using post-tensioning tendon (PT) systems and systems created by adding steel springs (PTS) to eliminate the weaknesses in column–beam connections in precast structures. To this end, real-sized column and beam specimens used in precast buildings were produced, and experiments were conducted under the cyclic loads defined by the American Concrete Institute (ACI) Committee, Report 374, simulating earthquake effects for three different connection types (DC, PT, and PTS). It was observed that the proposed PTS connection type dissipated approximately one-third of the energy transferred to the joint through elastic deformation in the springs, compared to the DC and PT connection types. This indicates that the PTS specimens transferred significantly less energy to the column–beam connection region. Consequently, the PTS system exhibited much less damage in the column foundation and especially the column–beam connection areas than other test specimens. In conclusion, it can be stated that the use of the PTS connection type in prefabricated structures has high potential to reduce damages due to dynamic loads such as earthquakes.https://www.mdpi.com/2075-5309/14/12/3910precastbeam–column connectionsdowel connectioncyclic loadspost-tensioningsteel springs |
| spellingShingle | Recep Kadir Pekgokgoz Ihsan Yakut Investigation of Passive Controlled Post-Tensioning System on the Structural Behaviour of Precast Reinforced Concrete Beam–Column Connections Buildings precast beam–column connections dowel connection cyclic loads post-tensioning steel springs |
| title | Investigation of Passive Controlled Post-Tensioning System on the Structural Behaviour of Precast Reinforced Concrete Beam–Column Connections |
| title_full | Investigation of Passive Controlled Post-Tensioning System on the Structural Behaviour of Precast Reinforced Concrete Beam–Column Connections |
| title_fullStr | Investigation of Passive Controlled Post-Tensioning System on the Structural Behaviour of Precast Reinforced Concrete Beam–Column Connections |
| title_full_unstemmed | Investigation of Passive Controlled Post-Tensioning System on the Structural Behaviour of Precast Reinforced Concrete Beam–Column Connections |
| title_short | Investigation of Passive Controlled Post-Tensioning System on the Structural Behaviour of Precast Reinforced Concrete Beam–Column Connections |
| title_sort | investigation of passive controlled post tensioning system on the structural behaviour of precast reinforced concrete beam column connections |
| topic | precast beam–column connections dowel connection cyclic loads post-tensioning steel springs |
| url | https://www.mdpi.com/2075-5309/14/12/3910 |
| work_keys_str_mv | AT recepkadirpekgokgoz investigationofpassivecontrolledposttensioningsystemonthestructuralbehaviourofprecastreinforcedconcretebeamcolumnconnections AT ihsanyakut investigationofpassivecontrolledposttensioningsystemonthestructuralbehaviourofprecastreinforcedconcretebeamcolumnconnections |