Increasing the operating time of hollow fiber membrane bundles used for water ultrafiltration

In order to increase the interval between cleanings of a hollow fiber membrane bundle (HFMB) used for water ultrafiltration, a numerical study and an experimental test were conducted. The relation between the water flow rate and shear stress along the hollow fiber membrane wires (HFMW) was studied f...

Full description

Saved in:
Bibliographic Details
Main Authors: Ciocănea Adrian, Simionescu Ștefan-Mugur, Opriș Florin
Format: Article
Language:English
Published: EDP Sciences 2025-01-01
Series:E3S Web of Conferences
Online Access:https://www.e3s-conferences.org/articles/e3sconf/pdf/2025/08/e3sconf_eenviro2024_05025.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832098455742316544
author Ciocănea Adrian
Simionescu Ștefan-Mugur
Opriș Florin
author_facet Ciocănea Adrian
Simionescu Ștefan-Mugur
Opriș Florin
author_sort Ciocănea Adrian
collection DOAJ
description In order to increase the interval between cleanings of a hollow fiber membrane bundle (HFMB) used for water ultrafiltration, a numerical study and an experimental test were conducted. The relation between the water flow rate and shear stress along the hollow fiber membrane wires (HFMW) was studied for three geometries. Three angles (α = 900,450,00) for the intake flow pipe (di = 25 mm) against the horizontal axis of a cylinder (Dc = 100 mm; L = 600 mm) containing one hollow fiber membrane wire (dw = 1 mm) were chosen for the numerical investigation; five different water flow rates (Q = 8…16 l/min) were considered. The values for the shear stresses along one membrane wire placed along the cylinder's central axis were computed. The findings show that the best geome1try for enhanced shear stress is obtained for α = 00. For this geometry a mean value of 1.1 Pa for the shear stress was obtain along the first 1/3 of the membrane wire at a minimum flow rate of Q = 8 l/min. Higher values for water flow rates do raise shear stress but increased energy consumption is needed. The tests were carried out on a HFMB with molecular weight cut-off (MWCO) of 0.097 μm, that was put in a glass cylinder with a horizontal axis, for μ = 900, μ = 00, and Q = 8 l/min. The results confirmed the conclusions of the numerical study i.e. the filtering capacity of the membrane was maintained higher by 6-6.5% for α = 00 comparing to α = 900 due to shear stress increase. For the flow rate of Q = 12 l/min the filtering capacity of the membrane did not increased. The study confirmed the hypothesis that for certain geometries there could be settle down optimum flow rates to minimize energy consumption during membrane operation but comprehensive research is needed.
format Article
id doaj-art-d819fe310c4f41e0a6fb11799cc9411a
institution Kabale University
issn 2267-1242
language English
publishDate 2025-01-01
publisher EDP Sciences
record_format Article
series E3S Web of Conferences
spelling doaj-art-d819fe310c4f41e0a6fb11799cc9411a2025-02-05T10:49:34ZengEDP SciencesE3S Web of Conferences2267-12422025-01-016080502510.1051/e3sconf/202560805025e3sconf_eenviro2024_05025Increasing the operating time of hollow fiber membrane bundles used for water ultrafiltrationCiocănea Adrian0Simionescu Ștefan-Mugur1Opriș Florin2Department of Hydraulics, Hydraulic Machinery and Environmental Engineering, National University of Science and Technology Politehnica of BucharestDepartment of Hydraulics, Hydraulic Machinery and Environmental Engineering, National University of Science and Technology Politehnica of BucharestDepartment of Hydraulics, Hydraulic Machinery and Environmental Engineering, National University of Science and Technology Politehnica of BucharestIn order to increase the interval between cleanings of a hollow fiber membrane bundle (HFMB) used for water ultrafiltration, a numerical study and an experimental test were conducted. The relation between the water flow rate and shear stress along the hollow fiber membrane wires (HFMW) was studied for three geometries. Three angles (α = 900,450,00) for the intake flow pipe (di = 25 mm) against the horizontal axis of a cylinder (Dc = 100 mm; L = 600 mm) containing one hollow fiber membrane wire (dw = 1 mm) were chosen for the numerical investigation; five different water flow rates (Q = 8…16 l/min) were considered. The values for the shear stresses along one membrane wire placed along the cylinder's central axis were computed. The findings show that the best geome1try for enhanced shear stress is obtained for α = 00. For this geometry a mean value of 1.1 Pa for the shear stress was obtain along the first 1/3 of the membrane wire at a minimum flow rate of Q = 8 l/min. Higher values for water flow rates do raise shear stress but increased energy consumption is needed. The tests were carried out on a HFMB with molecular weight cut-off (MWCO) of 0.097 μm, that was put in a glass cylinder with a horizontal axis, for μ = 900, μ = 00, and Q = 8 l/min. The results confirmed the conclusions of the numerical study i.e. the filtering capacity of the membrane was maintained higher by 6-6.5% for α = 00 comparing to α = 900 due to shear stress increase. For the flow rate of Q = 12 l/min the filtering capacity of the membrane did not increased. The study confirmed the hypothesis that for certain geometries there could be settle down optimum flow rates to minimize energy consumption during membrane operation but comprehensive research is needed.https://www.e3s-conferences.org/articles/e3sconf/pdf/2025/08/e3sconf_eenviro2024_05025.pdf
spellingShingle Ciocănea Adrian
Simionescu Ștefan-Mugur
Opriș Florin
Increasing the operating time of hollow fiber membrane bundles used for water ultrafiltration
E3S Web of Conferences
title Increasing the operating time of hollow fiber membrane bundles used for water ultrafiltration
title_full Increasing the operating time of hollow fiber membrane bundles used for water ultrafiltration
title_fullStr Increasing the operating time of hollow fiber membrane bundles used for water ultrafiltration
title_full_unstemmed Increasing the operating time of hollow fiber membrane bundles used for water ultrafiltration
title_short Increasing the operating time of hollow fiber membrane bundles used for water ultrafiltration
title_sort increasing the operating time of hollow fiber membrane bundles used for water ultrafiltration
url https://www.e3s-conferences.org/articles/e3sconf/pdf/2025/08/e3sconf_eenviro2024_05025.pdf
work_keys_str_mv AT ciocaneaadrian increasingtheoperatingtimeofhollowfibermembranebundlesusedforwaterultrafiltration
AT simionescustefanmugur increasingtheoperatingtimeofhollowfibermembranebundlesusedforwaterultrafiltration
AT oprisflorin increasingtheoperatingtimeofhollowfibermembranebundlesusedforwaterultrafiltration