Synchronized Control for Five-Story Building under Earthquake Loads
Synchronized control is implemented for a five-story building under earthquake loads and its capabilities are investigated for protection of building under earthquake. In this regard, we applied H2/LQG control algorithm in form of synchronized control for structural vibration reduction. Simulation r...
Saved in:
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
Wiley
2015-01-01
|
Series: | Journal of Applied Mathematics |
Online Access: | http://dx.doi.org/10.1155/2015/507306 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1832545607066058752 |
---|---|
author | Javad Mesbahi Alaeddin Malek |
author_facet | Javad Mesbahi Alaeddin Malek |
author_sort | Javad Mesbahi |
collection | DOAJ |
description | Synchronized control is implemented for a five-story building under earthquake loads and its capabilities are investigated for protection of building under earthquake. In this regard, we applied H2/LQG control algorithm in form of synchronized control for structural vibration reduction. Simulation results of modeling indicated that not only the provided control is able to reduce the responses of vibrations for the structure, but also it is even capable of supplying the objectives of synchronized control at the same time. Numerical results for uncontrolled, traditional H2/LQG control and synchronized control coupled with H2/LQG algorithm are presented. It is shown that for El Centro and Bam earthquakes the synchronized control is more efficient to reduce damage to the given structures. |
format | Article |
id | doaj-art-d7f78162ec9048189f95d56eda24edea |
institution | Kabale University |
issn | 1110-757X 1687-0042 |
language | English |
publishDate | 2015-01-01 |
publisher | Wiley |
record_format | Article |
series | Journal of Applied Mathematics |
spelling | doaj-art-d7f78162ec9048189f95d56eda24edea2025-02-03T07:25:17ZengWileyJournal of Applied Mathematics1110-757X1687-00422015-01-01201510.1155/2015/507306507306Synchronized Control for Five-Story Building under Earthquake LoadsJavad Mesbahi0Alaeddin Malek1Department of Mathematics, Payame Noor University, Tehran 19395-4697, IranDepartment of Applied Mathematics, Faculty of Mathematical Sciences, Tarbiat Modares University, P.O. Box 14115-134, Tehran 1411713116, IranSynchronized control is implemented for a five-story building under earthquake loads and its capabilities are investigated for protection of building under earthquake. In this regard, we applied H2/LQG control algorithm in form of synchronized control for structural vibration reduction. Simulation results of modeling indicated that not only the provided control is able to reduce the responses of vibrations for the structure, but also it is even capable of supplying the objectives of synchronized control at the same time. Numerical results for uncontrolled, traditional H2/LQG control and synchronized control coupled with H2/LQG algorithm are presented. It is shown that for El Centro and Bam earthquakes the synchronized control is more efficient to reduce damage to the given structures.http://dx.doi.org/10.1155/2015/507306 |
spellingShingle | Javad Mesbahi Alaeddin Malek Synchronized Control for Five-Story Building under Earthquake Loads Journal of Applied Mathematics |
title | Synchronized Control for Five-Story Building under Earthquake Loads |
title_full | Synchronized Control for Five-Story Building under Earthquake Loads |
title_fullStr | Synchronized Control for Five-Story Building under Earthquake Loads |
title_full_unstemmed | Synchronized Control for Five-Story Building under Earthquake Loads |
title_short | Synchronized Control for Five-Story Building under Earthquake Loads |
title_sort | synchronized control for five story building under earthquake loads |
url | http://dx.doi.org/10.1155/2015/507306 |
work_keys_str_mv | AT javadmesbahi synchronizedcontrolforfivestorybuildingunderearthquakeloads AT alaeddinmalek synchronizedcontrolforfivestorybuildingunderearthquakeloads |