MEASURING OF X-RAY SOURCE SIZE BY USING COMPOUND REFRACTIVE X-RAY LENS
Compound refractive lens was used for measuring size of 2-3 beamline Standford synchrotron radiation source and a size of microfocus X-ray tube. X-ray beam from the source was focused by the lens and parameters of the beam at image plane were measured. Scanning diaphragm and X-ray CCD-camera were us...
Saved in:
Main Author: | |
---|---|
Format: | Article |
Language: | English |
Published: |
Belarusian National Technical University
2015-04-01
|
Series: | Приборы и методы измерений |
Subjects: | |
Online Access: | https://pimi.bntu.by/jour/article/view/142 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1832543670926049280 |
---|---|
author | Yu. V. Dudchik |
author_facet | Yu. V. Dudchik |
author_sort | Yu. V. Dudchik |
collection | DOAJ |
description | Compound refractive lens was used for measuring size of 2-3 beamline Standford synchrotron radiation source and a size of microfocus X-ray tube. X-ray beam from the source was focused by the lens and parameters of the beam at image plane were measured. Scanning diaphragm and X-ray CCD-camera were used for measuring X-ray beam. It was found that the vertical size of synchrotron source is equal to 0,6 mm and the size of the X-ray tube focal spot is equal to 60 micrometers. |
format | Article |
id | doaj-art-d6ada924f90d4488986c95fd6ef2b755 |
institution | Kabale University |
issn | 2220-9506 2414-0473 |
language | English |
publishDate | 2015-04-01 |
publisher | Belarusian National Technical University |
record_format | Article |
series | Приборы и методы измерений |
spelling | doaj-art-d6ada924f90d4488986c95fd6ef2b7552025-02-03T11:37:43ZengBelarusian National Technical UniversityПриборы и методы измерений2220-95062414-04732015-04-01027580136MEASURING OF X-RAY SOURCE SIZE BY USING COMPOUND REFRACTIVE X-RAY LENSYu. V. Dudchik0Институт прикладных физических проблем им. А.Н. Севченко Белорусского государственного университета, г. МинскCompound refractive lens was used for measuring size of 2-3 beamline Standford synchrotron radiation source and a size of microfocus X-ray tube. X-ray beam from the source was focused by the lens and parameters of the beam at image plane were measured. Scanning diaphragm and X-ray CCD-camera were used for measuring X-ray beam. It was found that the vertical size of synchrotron source is equal to 0,6 mm and the size of the X-ray tube focal spot is equal to 60 micrometers.https://pimi.bntu.by/jour/article/view/142x-rayssynchrotron radiationx-ray tubecompound refractive x-ray lens |
spellingShingle | Yu. V. Dudchik MEASURING OF X-RAY SOURCE SIZE BY USING COMPOUND REFRACTIVE X-RAY LENS Приборы и методы измерений x-rays synchrotron radiation x-ray tube compound refractive x-ray lens |
title | MEASURING OF X-RAY SOURCE SIZE BY USING COMPOUND REFRACTIVE X-RAY LENS |
title_full | MEASURING OF X-RAY SOURCE SIZE BY USING COMPOUND REFRACTIVE X-RAY LENS |
title_fullStr | MEASURING OF X-RAY SOURCE SIZE BY USING COMPOUND REFRACTIVE X-RAY LENS |
title_full_unstemmed | MEASURING OF X-RAY SOURCE SIZE BY USING COMPOUND REFRACTIVE X-RAY LENS |
title_short | MEASURING OF X-RAY SOURCE SIZE BY USING COMPOUND REFRACTIVE X-RAY LENS |
title_sort | measuring of x ray source size by using compound refractive x ray lens |
topic | x-rays synchrotron radiation x-ray tube compound refractive x-ray lens |
url | https://pimi.bntu.by/jour/article/view/142 |
work_keys_str_mv | AT yuvdudchik measuringofxraysourcesizebyusingcompoundrefractivexraylens |