Kinematic Analysis of a Six-Degrees-of-Freedom Model Based on ISB Recommendation: A Repeatability Analysis and Comparison with Conventional Gait Model
Objective. The purpose of the present work was to assess the validity of a six-degrees-of-freedom gait analysis model based on the ISB recommendation on definitions of joint coordinate systems (ISB 6DOF) through a quantitative comparison with the Helen Hays model (HH) and repeatability assessment. M...
Saved in:
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
Wiley
2015-01-01
|
Series: | Applied Bionics and Biomechanics |
Online Access: | http://dx.doi.org/10.1155/2015/503713 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1832550451450478592 |
---|---|
author | Magdalena Żuk Celina Pezowicz |
author_facet | Magdalena Żuk Celina Pezowicz |
author_sort | Magdalena Żuk |
collection | DOAJ |
description | Objective. The purpose of the present work was to assess the validity of a six-degrees-of-freedom gait analysis model based on the ISB recommendation on definitions of joint coordinate systems (ISB 6DOF) through a quantitative comparison with the Helen Hays model (HH) and repeatability assessment. Methods. Four healthy subjects were analysed with both marker sets: an HH marker set and four marker clusters in ISB 6DOF. A navigated pointer was used to indicate the anatomical landmark position in the cluster reference system according to the ISB recommendation. Three gait cycles were selected from the data collected simultaneously for the two marker sets. Results. Two protocols showed good intertrial repeatability, which apart from pelvic rotation did not exceed 2°. The greatest differences between protocols were observed in the transverse plane as well as for knee angles. Knee internal/external rotation revealed the lowest subject-to-subject and interprotocol repeatability and inconsistent patterns for both protocols. Knee range of movement in transverse plane was overestimated for the HH set (the mean is 34°), which could indicate the cross-talk effect. Conclusions. The ISB 6DOF anatomically based protocol enabled full 3D kinematic description of joints according to the current standard with clinically acceptable intertrial repeatability and minimal equipment requirements. |
format | Article |
id | doaj-art-d55a117577d249699439e8060d02746e |
institution | Kabale University |
issn | 1176-2322 1754-2103 |
language | English |
publishDate | 2015-01-01 |
publisher | Wiley |
record_format | Article |
series | Applied Bionics and Biomechanics |
spelling | doaj-art-d55a117577d249699439e8060d02746e2025-02-03T06:06:51ZengWileyApplied Bionics and Biomechanics1176-23221754-21032015-01-01201510.1155/2015/503713503713Kinematic Analysis of a Six-Degrees-of-Freedom Model Based on ISB Recommendation: A Repeatability Analysis and Comparison with Conventional Gait ModelMagdalena Żuk0Celina Pezowicz1Department of Biomedical Engineering, Mechatronics and Theory of Mechanisms, Faculty of Mechanical Engineering, Wrocław University of Technology, Łukasiewicza 7/9, 50-371 Wrocław, PolandDepartment of Biomedical Engineering, Mechatronics and Theory of Mechanisms, Faculty of Mechanical Engineering, Wrocław University of Technology, Łukasiewicza 7/9, 50-371 Wrocław, PolandObjective. The purpose of the present work was to assess the validity of a six-degrees-of-freedom gait analysis model based on the ISB recommendation on definitions of joint coordinate systems (ISB 6DOF) through a quantitative comparison with the Helen Hays model (HH) and repeatability assessment. Methods. Four healthy subjects were analysed with both marker sets: an HH marker set and four marker clusters in ISB 6DOF. A navigated pointer was used to indicate the anatomical landmark position in the cluster reference system according to the ISB recommendation. Three gait cycles were selected from the data collected simultaneously for the two marker sets. Results. Two protocols showed good intertrial repeatability, which apart from pelvic rotation did not exceed 2°. The greatest differences between protocols were observed in the transverse plane as well as for knee angles. Knee internal/external rotation revealed the lowest subject-to-subject and interprotocol repeatability and inconsistent patterns for both protocols. Knee range of movement in transverse plane was overestimated for the HH set (the mean is 34°), which could indicate the cross-talk effect. Conclusions. The ISB 6DOF anatomically based protocol enabled full 3D kinematic description of joints according to the current standard with clinically acceptable intertrial repeatability and minimal equipment requirements.http://dx.doi.org/10.1155/2015/503713 |
spellingShingle | Magdalena Żuk Celina Pezowicz Kinematic Analysis of a Six-Degrees-of-Freedom Model Based on ISB Recommendation: A Repeatability Analysis and Comparison with Conventional Gait Model Applied Bionics and Biomechanics |
title | Kinematic Analysis of a Six-Degrees-of-Freedom Model Based on ISB Recommendation: A Repeatability Analysis and Comparison with Conventional Gait Model |
title_full | Kinematic Analysis of a Six-Degrees-of-Freedom Model Based on ISB Recommendation: A Repeatability Analysis and Comparison with Conventional Gait Model |
title_fullStr | Kinematic Analysis of a Six-Degrees-of-Freedom Model Based on ISB Recommendation: A Repeatability Analysis and Comparison with Conventional Gait Model |
title_full_unstemmed | Kinematic Analysis of a Six-Degrees-of-Freedom Model Based on ISB Recommendation: A Repeatability Analysis and Comparison with Conventional Gait Model |
title_short | Kinematic Analysis of a Six-Degrees-of-Freedom Model Based on ISB Recommendation: A Repeatability Analysis and Comparison with Conventional Gait Model |
title_sort | kinematic analysis of a six degrees of freedom model based on isb recommendation a repeatability analysis and comparison with conventional gait model |
url | http://dx.doi.org/10.1155/2015/503713 |
work_keys_str_mv | AT magdalenazuk kinematicanalysisofasixdegreesoffreedommodelbasedonisbrecommendationarepeatabilityanalysisandcomparisonwithconventionalgaitmodel AT celinapezowicz kinematicanalysisofasixdegreesoffreedommodelbasedonisbrecommendationarepeatabilityanalysisandcomparisonwithconventionalgaitmodel |