Estimation of Blood Pressure by Image-Free, Wearable Ultrasound

Abstract 1.28 billion adults worldwide have high pressure, and only 21% of people have it under control. If high blood pressure (BP) is not diagnosed and treated properly, then there is a high risk for cardiovascular diseases, the main cause of mortality. Ultrasound has emerged as a potential medica...

Full description

Saved in:
Bibliographic Details
Main Author: Ana Belen Amado Rey
Format: Article
Language:English
Published: BMC 2024-05-01
Series:Artery Research
Subjects:
Online Access:https://doi.org/10.1007/s44200-024-00048-6
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1832571889141153792
author Ana Belen Amado Rey
author_facet Ana Belen Amado Rey
author_sort Ana Belen Amado Rey
collection DOAJ
description Abstract 1.28 billion adults worldwide have high pressure, and only 21% of people have it under control. If high blood pressure (BP) is not diagnosed and treated properly, then there is a high risk for cardiovascular diseases, the main cause of mortality. Ultrasound has emerged as a potential medical imaging system to monitor cardiovascular health. It is comfortable, noninvasive, safe, and a very well-established and well-known technology. However, there are currently no commercial single ultrasound systems to directly quantify vascular parameters, without the need for complex imaging algorithms, additional software-based solutions, and high energy demands that limit portable and prolonged measurements. In this paper, we present the steps to design an image-free novel ultrasound device to continuously extract vital parameters, with a focus on BP. Moreover, as the BP waveforms are amplified toward the periphery (i.e., from the aorta to the radial artery), we applied mathematical models and algorithms, specific to the site of measurement, to accurately extract BP. We validated these algorithms in silico, in vitro, and ex vivo, where tissue and artery phantoms help emulate human physiology. In young subjects, an in silico pulse pressure (PP) correlation of 0.978 and a mean difference of (– 2.85 ± 2.57) mmHg at the radial artery were achieved. The ex vivo PP correlation was 0.986, with a mean difference of (1.72 ± 3.29) mmHg. Soon thereafter, in vivo measurements of BP and stiffness, and their correlation analysis will be performed to corroborate the accuracy of the developed proof-of-concept device.
format Article
id doaj-art-d3f9d683017543ae8994c56362f1e79f
institution Kabale University
issn 1876-4401
language English
publishDate 2024-05-01
publisher BMC
record_format Article
series Artery Research
spelling doaj-art-d3f9d683017543ae8994c56362f1e79f2025-02-02T12:14:54ZengBMCArtery Research1876-44012024-05-013011810.1007/s44200-024-00048-6Estimation of Blood Pressure by Image-Free, Wearable UltrasoundAna Belen Amado Rey0Department of Microsystems Engineering (IMTEK), IMBIT - Neuroprobes, University of FreiburgAbstract 1.28 billion adults worldwide have high pressure, and only 21% of people have it under control. If high blood pressure (BP) is not diagnosed and treated properly, then there is a high risk for cardiovascular diseases, the main cause of mortality. Ultrasound has emerged as a potential medical imaging system to monitor cardiovascular health. It is comfortable, noninvasive, safe, and a very well-established and well-known technology. However, there are currently no commercial single ultrasound systems to directly quantify vascular parameters, without the need for complex imaging algorithms, additional software-based solutions, and high energy demands that limit portable and prolonged measurements. In this paper, we present the steps to design an image-free novel ultrasound device to continuously extract vital parameters, with a focus on BP. Moreover, as the BP waveforms are amplified toward the periphery (i.e., from the aorta to the radial artery), we applied mathematical models and algorithms, specific to the site of measurement, to accurately extract BP. We validated these algorithms in silico, in vitro, and ex vivo, where tissue and artery phantoms help emulate human physiology. In young subjects, an in silico pulse pressure (PP) correlation of 0.978 and a mean difference of (– 2.85 ± 2.57) mmHg at the radial artery were achieved. The ex vivo PP correlation was 0.986, with a mean difference of (1.72 ± 3.29) mmHg. Soon thereafter, in vivo measurements of BP and stiffness, and their correlation analysis will be performed to corroborate the accuracy of the developed proof-of-concept device.https://doi.org/10.1007/s44200-024-00048-6Vascular ultrasoundBlood pressureStiffnessPatient-specific measurementsMock circulation systemsDevice validation
spellingShingle Ana Belen Amado Rey
Estimation of Blood Pressure by Image-Free, Wearable Ultrasound
Artery Research
Vascular ultrasound
Blood pressure
Stiffness
Patient-specific measurements
Mock circulation systems
Device validation
title Estimation of Blood Pressure by Image-Free, Wearable Ultrasound
title_full Estimation of Blood Pressure by Image-Free, Wearable Ultrasound
title_fullStr Estimation of Blood Pressure by Image-Free, Wearable Ultrasound
title_full_unstemmed Estimation of Blood Pressure by Image-Free, Wearable Ultrasound
title_short Estimation of Blood Pressure by Image-Free, Wearable Ultrasound
title_sort estimation of blood pressure by image free wearable ultrasound
topic Vascular ultrasound
Blood pressure
Stiffness
Patient-specific measurements
Mock circulation systems
Device validation
url https://doi.org/10.1007/s44200-024-00048-6
work_keys_str_mv AT anabelenamadorey estimationofbloodpressurebyimagefreewearableultrasound